Loading...
ST9302-LR001013 (2)ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/.__~_L~6-8023 TESTED FOR CITY OF COPPELL COPPELL, TEXAS REPORT OF FIELD COMPACTION TESTS DATE 10113/00 PROJECT SANDY LAKE ROAD PROJECT NO. ST 93-02 COPPELL, TEXAS OUR REPORT NO. 98881-157A TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPT~,~ NUMBER ~ DRY DENSITY MOISTURE DRY DENSrW COMPACTION COMMENT* 489 10/13/00 FG 10L 16.6 110.3 15.1 107 97 3-C 490 10113/00 FG 10L 16.6 110.3 17.9 103 93 3-B 491 10113/00 FG 10L 16.6 110.3 18.3 102 92 3-B 492 10/13/00 FG 10L 16.6 110.3 18.5 108 98 3-A 493 10/13100 FG 11L 13.7 109.4 14.8 106 97 3-A 494 10/13/00 FG 11 L 13.7 109.4 15.9 103 94 3-B 495 10/13~00 FG 11L 13.7 109.4 12.8 104 95 3-BC :ATION: 489 CENTER LINE SANDY LAKE ROAD WEST BOUND AT STATION #91+00 490 CENTER LINE SANDY LAKE ROAD WEST BOUND AT STATION #93+00 491 CENTER LINE SANDY LAKE ROAD WEST BOUND AT STATION #95+00 492 CENTER LINE SANDY LAKE ROAD WEST BOUND AT STATION #97+00 493 CENTER LINE SANDY LAKE ROAD WEST BOUND AT STATION #99+00 494 CENTER LINE SANDY LAKE ROAD WEST BOUND AT STATION #101+00 495 CENTER LINE SANDY LAKE ROAD WEST BOUND AT STATION #102+50 CC: NONE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PE~ COMPACTION COMPLY WITH SPECIFICATIONS _~ 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILbT~D C. PERCENT IN PLACE ~RE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Con~ultil