Corners Coppell-CS 860826 (3)Maxim Engineers, Inc.
Geotechnical
Materials Testing
Consultants
August 26, 1986
Mr. Ed Power, P.E.
C~y of CoppeU
P.O. Box 478
Coppell, Texas 75019
Shopping Center, Sandy
Lake at McArthur
Boulevard, Coppall,
Texas
Dear Mr. Powelh
We have performed a geotechnical investigation for the referenced
project (our report number B-5-0244, dated 05/20/85), and in this report
we recommended that a four (4) inch thick concrete pavement be used in
areas where light vehicular traffic is expected. The four (4) inch
pavement was derived at using the following design parameters.
- Expected pavement life: 15-20 years
- Average 10 heaviest wheel loads: 8 kips
- Number of applications per day: 10
- Number of equivalent 18 kips; single axle loads: 14,000
- Traffic Number (based on the above): 10 or less
- Design Number (DN): 2.5
The following structural numbers were used for the pavement components:
- Concrete: 0.5
- Select Filh 0.12
- Natural Soils: 0.08
2342Fabens
FO. Box 59902
Dallas, Texas 75229
(214)247-7575
Mr. Ed Powell, P.E.
August 26, 1986
Page 2
A pavement cross section consisting of four (4) inches of concrete and
12 inches of select fill will have a structural number of 3.44, which
exceeds the required design number of 2.5.
We trust the information provided herein is sufficient for your use.
Please contact us if we may be of further service.
Yours truly,
MAXIM ENGINEERS, INC.
Saad M. Hineidi, P.E.
Vice President
SMH:sas