Corners Coppell-CS 850520 (2)May 20, 1985 Mr. William Go Barnes Beeson-Stone-Bighly 6500 Greenville Avenue Suite 555 Dallas, Texas 75206 Re: Report No. B-5-0244 Geotechnical Investigation Proposed Sandy Lake at~. · MacArthur Shopping Center Coppell, Texas Dear Mr. Barnes: Submitted herein is a report summarizing the results of the geotechnical investigation performed at the above referenced project. We. trust~t~~..lldations:Lderived~[rom_this investigation wil~_.pro-_ vide an adequate and economical foundation design. As your project develops we would be pleased to assist you with material quality inspec- tion and quality assurance testing. We thank you for the opportunity to provide you with our professional services. If we can be of further assistance, please do not hesitate to contact us. Respectfully submitted, MAXIM ENGINEERS, INC. Saad M. Hineidi, P.E. Vice President George W. Perdue, P.E. President SMH: GWP :lsl SYNOPSIS PROPOSED SANDY LAKE AT MacARTtIUR StlOPPING CENTER COPPELL, TEXAS REPORT NO. B-5-0244 The synopsis is included for the convenience of our clients and is intended only as a general overview of the results of this investiga- tion. Designs based upon the information in this report should be made only after reading and thoroughly understanding the recommendations as they are stated in the main body of the report. SITE LOCATION The site is located on the southeast corner of the intersection of Sandy Lake Road and MacArthur Boulevard in Coppell, Texas. II. SUBSURFACE SOIL DESCRIPTION The near surface softs encountered consisted of dark brown, yellowish brown and gray clays, sandy clays, clayey sands and sands. One (1) to three (3) feet of fill material encountered in test borings B-6, B-9 and B-10. Subsurface water was encountered in some of the test borings at the time this investigation was performed. III. FOUNDATION TYPE The building's structural loads should be supported by one of the following systems: Auger excavated, cast-in-place, straight sided reinforced concrete piers founded at least three (3) feet into the primary gray shale layer encountered at 14.0 to 25.0 feet below the ground surface. These piers may be designed using an allowable end bearing pressure of 18,000 pounds per square foot, and a skin friction value of 2,200 pounds per square foot; or Auger excavated, cast-in-place underreamed reinforced concrete piers founded between 10 and 12 feet below the existing ground surface within the brown, yellowish brown and gray clay layers. These piers may be designed using an allowable end bearing pressure of 4.400 pounds per square foot. IV. BUILDING FLOOR SLABS Concrete floor slabs may be placed on one of the following grad es: a. 2.0 to 2.5 feet of select fill placed on compacted existing soils. Estimated differential floor slab movement - 0.75 to 1.00 inches. sub- be Structural floor slab with a minimum of a six (6) inch void space provided between the exposed subgrade and the concrete slab. GRADE BEAMS All grade beams should be separated from the subgrade by a void of not less than six (6) inches.