Vista Ridge 1R-8 D-LR051017SAM ENGiNEERiNG & TESTING, C.P.
Serving The Geo-lndustry Since 1974
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone: (972) 790-1910 - FAX: (972) 790-0967
CONCRETE PLACEMENT INSPECTION & STRENGTH
CLIENT:
JBP, LP
5301 Village Creek Drive, Suite A
Piano, TX 75093
PROJECT:
~TTN:
E&T TECHNICIAN:
LOCATION OF PLACEMENT:
The Plaza Infrastructure
Highway 121 & Ridgemont
LewisvJlle & Coppell, TX
Neal Heckel
Mark Brumley
Inlet Bottom
TEST REPORT
STANDARD 6" X 12"
AREA 28.27 SQ. IN.
REPORT DATE: 10/17105
SAMPLE DATE: 9/19/05
PROJECT NO.: 308TXIK5
REPORT NO.: 39
PAGE 1 OF 1
Time Arrived:
Time Left:
Slump (Inches):
Concrete Temperature (F):
% Air Content:
Total No. of Test C~/linders Made:
Total Cubic Yards Placed:
Added Water:
Weather Conditions:
Air Temperature (F):
of Fresh Concrete:
2:30 PM
3:30 PM
4
94
N/A
4
10
N/A
Sunny & Hot
97
Concrete Supplier:
Ticket #:
Truck #:
Time Batched:
Time Sampled:
Product Code:
:ement:
F~ Ash:
Coarse A~lgregate:
Water:
149 % Air Content:
LMC
7156561
1118
2:31 PM
3:15 PM
1851
N/A
N/A
N/A
N/A
N/A
28
1D 28
Curing ASTM C-31
Slump ASTM C-143
Remarks:
3536
4314
10/17~05 125,000 4420
Cylinder Made By:
;-39 & 231 SE&T
Tested concrete meets/exceeds required strength.
4200/28
4200/28
4200/28
4200/28
Cylinders Tested By:
SE&T
Very Truly Yours,
Sadik (SAM) AI-Musawe, MSc., Ph.D., P.E.
Civil & Environmental Engineer
Texas Registration Number: 61893
This report is for the sole use of th~ client addressed. The use of our company name must receive our prior written consent.
This report only/applies to the samples tested and does not necessarily represent identical or similar samples.
G:12OO51308txik51CpistrlCpistr3OIBE