Loading...
ST9302-LR 991021 (3)ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR CITY OF COPPELL COPPELL, TEXAS REPORT OF FIELD COMPACTION TESTS DATE 10/21/99 PROJECT SANDY LAKE ROAD PROJECT NO. ST 93-02 COPPELL, TEXAS OUR REPORT NO. 98881-95A TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE iN PLACE PERCENT NO. DATEDEPT~..~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 311 10/21/99 FG-5.0 6 12.5 111.2 13.1 108 97 1-A 312 10/21/99 FG-4.0 6 12.5 111.2 14.8 107 96 1-A 313 10121199 FG-3.0 6 12.5 111.2 12.9 108 97 1-A 314 10/21/99 FG-2.0 6 12.5 111.2 12.8 110 99 1-A 315 10/21/99 FG-1.0 6 12.5 111.2 13.3 108 97 I-A 316 10/21/99 FG 8L 22.2 94.7 23.2 97 102 3-A 317 10/21/99 FG 8L 22.2 94.7 20.2 92 97 3-A TEST LOCATION: 311 RCCR 30" WATER LINE NORTH SIDE OF SANDY LAKE ROAD AT STATION #75+16 312 RCCR 30" WATER LINE NORTH SIDE OF SANDY LAKE ROAD AT STATION #75+25 313 RCCR 30" WATER LINE NORTH SIDE OF SANDY LAKE ROAD AT STATION #75+35 314 RCCR 30" WATER LINE NORTH SIDE OF SANDY LAKE ROAD AT STATION #75+40 315 RCCR 30" WATER LINE NORTH SIDE OF SANDY LAKE ROAD AT STATION #75+45 316 WATER VALVE NORTH SIDE OF SANDY LAKE ROAD AT STATION #42+60 317 MANHOLE AT STATION #43+00 1 FILL 2 NATURALSUBGRADE 3 LIME STABILIZED 4 CEMENTTREATED *A iN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D RETEST Resj;~ctfully S ub~e.~d ALPHA TESTING, IN13. ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR CITY OF COPPELL DATE 10121/99 COPPELL, TEXAS PROJECT SANDY LAKE ROAD OUR REPORT NO. 98881-95B PROJECT NO. ST 93-02 COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATED E PTH"~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 318 10/21/99 FG 8L 22.2 94,7 21.3 91 96 3-A TEST LOCATION: 318 NORTH SIDE OF SANDY LAKE ROAD MANHOLE AT STATION #37+85 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED w A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D, RETEST R~'l;)ectfully Subm~l Geotechnical Engineering · Consfruction Materia~ Tesfir~ · Environmental E~ · Consuffing