Loading...
ST8201-CS 890608June 8, 1989 MEMORANDUM TO: FROM: RE: John Karlsruher, PiEs, Ginn, Inc. Russell R. Doyl~.E.,~/ City Engineer SANDY LAKE CROSSING - REQUESTED LEFT-TURN LANE DENTON TAP ROAD - BELTLINE TO SANDY LAKE ROAD Since Kevin Peiffer's May 24, 1989, review letter (Copy Attached), and Kevin's and my response to the City Council on May 23, 1989, Staff met with the applicant on Friday, June 2, 1989, and have the following comments and inquiries. (Please refer to attached submittal). The applicant indicates that the median opening for the McDonald's south drive on Denton Tap Road (common with the Shopping Center and new Kentucky Fried Chicken), is not the standard required separation distance from the Denton Tap Road intersection nose/opening. Not allowing the median opening will load the 173-2010 P.M. peak hour voluale onto the "Planned Median Opening", a lesser accessible entrance, perhaps requiring signalization and phasing. What was the design premise/assumption at providing the secondary entrance of this development (Sandy Lake Crossing), a median opening and not the access drive that will service the anchor stores (i.e. generate the most traffic)? 3. What is meant by monitor? 4. What would the criteria be for closing the median opening, congestion, accidents, City Engineer perception? Would it be acceptable to Ginn, Inc. to receive the design drawings from Kimley-Horn and Associates, Inc., review and approve them, and then allow them to become the basis for change orders to Denton Tap Road C.I.P. Project? Please let me know your response as the Project Engineer for the design and construction of this C.I.P. Project. Thanks. RRD/lsg JK/SLC ~EDIAN ACCESS DE I VAL ATI N Restricted Left Turn Access on Denton Tap Between Sandy Lake and Braewood City Council Briefing Material Prepared by Kimley-Horn and Associates, Inc. 12660 Colt Road, Suite 200 Dallas, Texas 75251 214/386-7007 May, 1989 //----'hr;, 14. 8 POTENTIAL SIGNAL O EXISTING SIGNAL Tabl. e 1 Lend Use; Density 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Service Station; Restaurant Retait; RetaiL; RetaiL; Supermarket; RetaiL; Medical Office; GeneraL Office; Medical Office; 1 Station 748 11 11 13 13 2,3~0 SF 470 25 20 25 22 3,780 SF ?59 40 32 40 35 4,687 SF 9~Z 50 39 50 44 3,184 SF (~0 3~ 27 3~ 30 1,505 SF 302 16 13 16 14 4,144 SF ~8 18 8 58 61 24,748 SF 2,~8 5~ ~ ~15 ~2 10,~5 SF 1,~1 32 14 ~ 100 58,6~ SF ?,358 2Z 10 2~ 253 33,000 SF 3,615 63 27 1~ 1~ 16,7~ SF 571 15 12 16 ~ 40,050 SF 691 ~ 12 15 ~ 220,5~ SF 7,535 20~ 15~ ~ 5~ TOTRL 28~618 ~ ~ ~ ~ 9176-02.TbL 9176.02 T-410/CD-2 of '89 1312 --~ 101 ~ 194. 828 183 DENTON TAP SANDY LAKE 205 2 47 132 2 149 PLANNED MEDIAN OPENING 233 REQUESTED MEDIAN OPENING 24 '-'"" ~ 32 DENTON TAP @ BRAEWOOD · 1. FULL ACCESS MEDIAN OPENING SPACING '/~0~ IT.~.-~' O 40 MPH DESIGN SPEED: · MINIMUM = 300 FT.; DESIRABLE = 530 FT. * REQUEST IS FOR RESTRICTED LEFT-TURN-ONLY DESIGN, PROVIDING 420 FT. MEDIAN OPENING SPACING, 2. SAFE SIGHT DISTANCE O 40 MPH DESIGN SPEED - 6 LANE ROADWAY~'....-~ LEFT .FROM MEDIAN. B.) 440 FT. MINIMUM FOR VEHICLES' EXITING RIGHT FROM THE DRIVEWAY. REQUEST PROVIDES APPROXIMATELY 700 FT. SAFE SIGHT DISTANCE FOR EACH MANEUVER. EFFECTIVE LEFT-TURN STORAGE LENGTH (UNStGNALIZED OPERATION) USING PROdECTED 2010 TRAFFIC VOLUMES: MINIMUM = 200 FT.; DESIRABLE 250 FT. REQUEST PROVIDES 225 FT. (9-11 PASSENGER VEHICLES)~ LEFT-TURN DECELERATION DISTANCE ~ 40 MPH DESIGN SPEED: MINIMUM TO STOP = .315 FT. ; MINIMUM TO 15 MPH TURN = 295 FT, REQUEST PROVIDES .515 FT. DECELERATION DISTANCE.