ST9302-LR 981117A
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263~4937 (Metro)
FAX: 972/406-8023
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR CITY OF COPPELL DATE 11/17/98
COPPELL, TEXAS
PROJECT SANDY LAKE ROAD OUR REPORT NO. 98881-6
PROJECT NO. ST 93-02
COPPELL, TEXAS
TEST DATA:
TEST ~ ELEV. SOIL ID oP~uuu MAYaMUU {.~B ~1 fi. ACE ~1 PLACE PERCENT
NO. DATE'~DEPTH ~ NUMBER MOISTURE DRY IDEN~TY MOISTURE DRY DENSITY COMPACTION COMMENT*
% PCF % PCF
9 11/17/98 FG-2.5 I 12.5 117.9 11.7 113 96 1-A
10 11/17/98 FG-1.5 I 12.5 117.9 11.7 113 96 1-A
11 11/17/98 FG I 12.5 117.9 12.4 112 95 1-A
12 11/17/98 FG 5 13.5 111.9 14.5 106 95 1-A
TEST LOCATION: UTILITIES
9 24" STORM DRAIN LINE AT STATION #88+00
10 24" STORM DRAIN LINE AT STATION #88+10
11 24" STORM DRAIN LINE AT STATION #8~ + 15
12 24" STORM DRAIN UNE.AT SI:ATION #~5+00
2. NATURAL SUBGRADE
3. UME STABILIZED
4. CEMENt' TREATED
A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
B. PERCENI' COMPACTION OOES NOT COMPLY WITH S~[CI~ICATIO~
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D. RETEST
] ' I .... !- F