ST8402-CS 891004TO:
CITY OF COPPELL
255 PARKWAY BLVD.
P. O. BOX 478
COPPELL, TEXAS 75019
PU~4_I C.
SUlTIE ICaO ~ LS -/1~
WE ARESENDING YOU [Attached
[ ~Mark Up Plans
[ ] Copy of Minutes
[ ] Change order
DATE: | PROJECT:
IO-4-09[ ~'ou~; ~ 4,0G
ATTENTION:
RE. J~HAI /~?r~l_S
Under Separate Cover via
] Plans
] Copy of Letter
the following item~
[ ] Prints
[~peCifications
COPIES DATE NO. DESCRIPTION
TMESE ARE TRANSMITTED as checked below:
[ ] For Your Use [ ] Approved as Noted
[~s Requested [ ] Approved as Submitted
[ ] For Review & Comment [ ] Note & Reply To:
[ ] Returned for Corrections
[ ] Note & Forward To:
Resubmit Copies for Approval [ ] Submit .Copies for Distribution
Return Corrected Prints [~V~eturn Markup Plans with Corrections
coPY TO:
COPPELL PUBLIC WORKS
September 29, 1989
John Karlsruher, Project Manager/Ginn Inc.
Richard Diano, Park Superintendent~
Landscaping/Irrigation Plan Review for Denton Tap
The comments noted below are a result of a review by myself and
Utilities Superintendent, Howard Pafford.
Specification Comments=
A telephone n~mher error occur in sec. 1.10 as noted in the
attached draft.
Add the words " and document any irregularities of of site
conditions by photograph or notation to Project Manager".
Sec. 1.13- the worked "the" is misaligned in
A - 12
E - the words "felt-tip" pen are to be added
Sec. 1.17 add Utilities division
add following sentence to close paragraph
Contact Utilities division at 462-8495 24 hours prior
installation or inspection is to take place.
to time
Sec. 1.20 Each Contractor shall attend all progress meetings as
requested by the Owner's Representative during their installation.
Sec. 2.09 add "an" to first sentence, last paragraph after, "shall
be..."
Sect. 2.11 Ail meters shall be 2" turbine meters capable of a
maximum continuous delivery of 160 gallons per minute.
Sec. 3.01 (B) contractor is misspelled in 2nd paragraph 3rd
sentence
PAGE 2
Landscaping/Irrigation
(C) Maximum static pressure allowed is 75 psi at point of
connection. Use of a pressure regulator is recommended
if this is exceeded and this must be approved by the Owner
and irrigation system designer prior to installation.
Sec. 3.06 Expansion Curls are to be 24" in length or greater for
all valves and common control wiring at each valve connection.
Landscaping plans.
Sec. 1.06 capitalize "Plants" in title of guarantee
Sec. 3.04 Last sentence in A should read "... 90% compaction .... "
(C) add (See diagram D-4)
Lawns and Grasses
Execution sec. 3.04 If should read It
Add to section 3.07 "The contractor shall provide the first cutting
and three additional cuttings of the turfgrass prior to City
accepting work.
RED/bb
xc~ Steve Goram, Director of Public Works
KARLSRUH. RED
TO
GINN, INC.
Consulting Engineers
17103 Preston Road
Suite 100, LB-118
DALLAS, TEXAS 75248
(214) 248-4900
WE ARE SENDING YOU ,~Attached [] Under separate cover via
/-
[] Shop drawings [] Prints ~ plans [] samples
[] Copy of letter [] Change order []
the following items:
Specifications
COPIES DATE NO. DESCRIPTION
THESE ARE TRANSMITTED as checked below:
[] For approval [] Approved as submitted [] Resubmit copies for approval
[] For your use [] Approved as noted [] Submit copies for distribution
[] As requested [] Returned for corrections [] Return__corrected prints
/l~For review and comment []