Loading...
CF-Cozby Library-LR051108Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 MOISTURE DENSITY RELATIONS Client: City of Coppell Ms. Sherri Moino PO Box 9478 Coppell TX 75019 Proj eet~Public Library - 177 N Heanz Coppell, Texas Services: Report No.: 244754 Project No.: 0510866 Date of Service: 11/04/2005 Report Date: 11/08/2005 Obtain a sample of material from the jobsite, bring the sample back to the laboratory and perform a moisture density relationship test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: H-B Construction, Inc. TEST FOR: Screen Wall Backfill MATERIAL: Dark Brown Sandy Clay w/ Limestone Fragments CLASSIFICATION: Screen Wall Backfill TEST METHOD: ASTM D-698 ASTM D-4318 Method A DATE SAMPLED: 11/04/2005 MATERIAL PREPARATION: Moist RAMMER TYPE: Mechanical SAMPLED BY: F. Calvillo SAMPLE LOCATION: Southwest Comer of Screen Wall REPORT OF TEST MAXIMUM DRY DENSITY, pef: 108.0 OPTIMIJM MOISTURE CONTENT, %: 18.0 109 MOISTURE DENSITY RELATIONS  Zeroair '~ )ids c Spe([ftc( ravit3 2.70 / / LIQUID LIMIT: 43 tot Dry PLASTIC LIMIT: 20 Density (pc0 PLASTICITY INDEX: 23 lOS lO3 101 MOISTURE CONTENT (%) Report Distribution: (1) City of Coppell (1) City of Coppell . (1) City of Coppell j ! CMT C ,erations Manager (1) H-B Constmction, Inc. LIMITATIONS: The test results presented herein v~re~rapa~ed based upon the specific samples provided for testing We a~sume no responsibility for variation in quaiity (composition, app*arance, etc.) or any other feature=of~imilar subject matter provided by persons or conditions over which we have no control Our letters and reports for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in f~ll without the written approval of Rone Engineering Services Ltd. Page 1 of 1 ' RONE ENGINEERING SERVICES, LTD. REPORT OF STRAIGHT SHAFT PIER INSPECTION Client: City of Coppell Report No.: 2439213 Project No.: 0510866 Droject: WT Cozby Public Library Date of Service: 10/24/2005 Page 2 of 2 Driller: King Paving Pier Identification B.7/11 Pier Diameter (in) 18 Depth of Pier From Surface (it) 24.00 Depth of Bearing Stratum From Surface (ft) 18.00 Required Penetration (it) 6.00 Actual Penetration (fi)* 6.00 Condition of Bottom (wet / dry) Dry Plumb Within Tolerance (yes / no) Yes Casing Diameter (in) / Casing Length (fi) 20 / 18 Number of Bars / Reinfoming Bar Size 5 / #6 Length of Reinfoming Steel (ft) 21.00 Time Drilling was Completed (am / pm) 3:21 PM Time Concrete was Placed (am / pm) 4:50 PM Depth of Pier From Top of Concrete (it) 21.80 Elevation: Surface (fi)** N/A Elevation: Top of Pier (fi)** N/A Elevation: Bottom of Pier (it)** N/A Elevation: Top of Bearing Stratum (it.)** N/A Bearing Stratum (description) Gray Shale Note: See report # for Compressive Strength Test Specimens. * Additional Pene~h'ation not requested unless noted. **Elevation by others Remarks: Stand-by time 9:00am-2:00pm due to all augers/casing being for 12" piem and having to be replaced. LIMrrATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composE[on, appearance, performance, etc.) or any other feature of similar subject maffer provided by persons or conditions over which we have no :;onth31. Our letters and reporls are for the exclusive use of the clients to whom they are addressed and sha~l not be reproduced except in full without the wdtten approval of Rone Engineering Services, Ltd.