Loading...
Freeport NIP(8.1)-CS051109November 9, 2005 PK No.: 2052-05.217 Ms. Charlene La Mattina, E.I.T. CITY OF COPPELL 255 Parkway Boulevard Coppell, Texas 75019 Re: FREEPORT XlV AND XV Coppell, Texas Dear Ms. La Mattina: This letter is to notify you that the enclosed Construction Plans have been revised in accordance with your November 3, 2005, Review Memorandum. The following items have been addressed as per the referenced review: WATER & SANITARY SEWER PLAN COMMENTS · Include existing and proposed utility crossings in the sanitary sewer profile. Verify that required spacing is met. Include encasement if deemed necessary. Response: Existing utility crossings shown on sanitary sewer profile. A 6" valve should be added to Detail 1 between the fire hydrant and the tee as indicated on the mark-ups. Update the call-outs on sheets C4.1 and C4.2 to reflect the modification. Response: 6" valve added to detail between the fire hydrant as shown on the markups. Call-outs have been updated to reflect the modification. FUTURE DRAINAGE PLAN COMMENTS This department is not yet in receipt of the modifications to the future Bethel Road plans, which you requested of TranSystems. Provide a copy of the proposed modifications and ensure that they are incorporated into this drawing set. Response: A copy of the future Bethel Road plans by TranSystems will be sent to the department in the next few days. Pacheco Koch has coordinated the future Freeport XIV and XV drainage plans with the future Bethel Road plans by TranSystems. CAJ/clt 2052-414 If you have any questions or need any additional information, please call at your earliest convenience. ~d~Sincerel ~