Loading...
Villas at LV-LR050423 ALPHA TESTING, INC. ~20~ Wisconsin St., Suite 1DO Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972(406-8023 TESTED FOR: HAWKINS - WELWOOD HOMES, L.P. CIO DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 04123/05 PROJECT: VILLAS AT LAKE VISTA PHASE ONE COPPELL, TEXAS OUR REPORT NO,: 04773-100 TEST DATA: TEST DATE ~ ELEV. SOIL ID OPTIMUa M~(IMUM LAB IN PLACE IN PLACE PERCENT COMMENT* MOISTURE DRY DENSITY MOISTURE DRY DENSI~' COMPACTION NO.DEPTH '~ NUMBER % PCF % PCF 1017 04/23/05 FG 5 16.5 110.5 20.1 106 96 1-A 1018 04/23/05 FG-0.5 5 16.5 110.5 16.5 109 99 1-A 1019 04123/05 FG 5 16.5 110.5 20.2 106 96 1-A 1020 04/23/05 FG-0.5 5 16.5 110.5 18.3 107 97 1-A 1021 04~23/05 FG 5 16.5 110.5 16.7 107 97 1-A 1022 04123~05 FG 5 16.5 110.5 19.1 105 . 95 1-A 1023 04123/05 FG-0.5 5 16.5 110.5 18.3 107 97 1-A TEST LOCATION: BUILDING PAD 1017 20' S AND 30' W FROM THE NE CORNER OF BLOCK B, PAD 4 1018 20' S AND 30' W FROM THE NE CORNER OF BLOCK B, PAD 5 1019 20' S AND 30' W FROM THE NE CORNER OF BLOCK B, PAD 5 1020 20' S AND 30'W FROM THE NE CORNER OF BLOCK B, PAD 6 1021 20' S AND 30' W FROM THE NE CORNER OF BLOCK B, PAD 8 1022 20' S AND 30' W FROM THE NE CORNER OF BLOCK B, PAD 23 1023 '20' S AND 30' W FROM THE NE CORNER OF BLOCK D, PAD 6 I FILL 2 NATURAL SUBGRADE 3 LIME STABILIZED 4 CEMENT TREATED · A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Subrn~ed, D RETEST CHARLES WILLIAMS ALPHA TESTING, INC Geotechnical Engineenng /r Construction Materials Testing /; Environmental Engineering I" Consulting ALPHA TESTING, INC. REPORT OF FIELD COMPACTION TESTS 2209 W~consin St., Suite 100 Dallos, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972~-8023 TESTED FOR: HAWKINS - WELWOOD HOMES, L.P. CIO DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS DATE: 04/23/05 PROJECT: VILLAS ATIAKE VISTA PHASE ONE COPPELL, TEXAS OUR REPORT NO.: 04773-100A TEST DATA: TEST DATE ~ELEV SOIL ID OPTIMUM MAXIMUM LAI~ IN PLACE IN PLACE PERCENT COMMENT* MOISTURE DRY DENSITY MOISTURE DRY DENSI3¥ COMPACTION NO.DEPTH '~ NUMBER % FCF % PCF 1024 04/23/05 FG 5 16.5 110.5 18.3 105 95 1-A 1025 04~23/05 FG-0.5 5 16.5 110.5 17.5 107 97 1-A 1026 04/23/05 FG 5 16.5 110.5 18.2 106 96 1-A 1027 04/23/05 FG-0.5 5 16.5 110.5 17.7 106 96 1-A 1028 04/23/05 FG 5 16.5 110.5 19.2 107 97 1-A 1029 04/23/05 FG-0.5 5 16.5 110.5 16.8 106 96 1-A 1030 04/23/05 FG 5 16.5 110.5 18.4 108 97 1-A TEST LOCATION: BUILDING PAD 1024 20' S AND 30' W FROM THE NE CORNER OF BLOCK D, PAD 6 1025 20' S AND 30' W FROM THE NE CORNER OF BLOCK D, PAD 7 1026 20' S AND 30' W FROM THE NE CORNER OF BLOCK D, PAD 7 1027 20' S AND 30' W FROM THE NE CORNER OF BLOCK D, PAD 8 1028 20' S AND 30' W FROM THE NE CORNER OF BLOCK D, PAD 8 1029 20' S AND 30' W FROM THE NE CORNER OF BLOCK D, PAD 9 1030 20' S AND 30' W FROM THE NE CORNER OF BLOCK D, PAD 9 FILL 2 NATURAL SUBGRADE 3 LIME STABILIZED 4 CEMENT TREATED *A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~ C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, Geotechnical Engineering /, Construction Materials Testing /; Environmental Engmeering ~' Consulting ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texos 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR: HAWKINS - WELWOOD HOMES, LP. CIO DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS DATE: 04123/05 PROJECT: VILLAS AT LAKE VISTA PHASE ONE COPPELL, TEXAS OUR REPORT NO.: 04773-100B TEST DATA: TEST DATE ~ELEV SOIL ID OPTIMUM MAXIMUM LAB IN PLACE iN PLACE PERCENT MOISTURE DRY DENSITY MOISTURE DRY DENEI"i~ COMMENT* NO.DEPTH '~ NUMBER % PCF % PCF COMPACTION 1031 04/23/05 FG-0.5 5 16.5 110.5 17.2 107 97 1-A 1032 04/23105 FG 5 16.5 110,5 18,5 108 98 1-A TEST LOCATION: BUILDING PAD 1031 20' S AND 30' W FROM THE NW CORNER OF BLOCK D, PAD 10 1032 20' S AND 30' W FROM THE NW CORNER OF BLOCK D, PAD 10 FILL NATURAL SUBGRADE LIME STABILIZED CEMENT TREATED · A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY W~TH SPECIFICATIONS B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFtCATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Sub?tted, D RETEST CHARLES WILLIAMS ALPHA TESTING, INC. Geotechnical Engineering / Construction Materials Testing /~ Environmental Engineering /; Consulting