Villas at LV-LR050420ALPHA TESTIN( , INC.
~ Wl~onsln ~t., Suite 100
Da&2s, Texas 7,5229
972/620-8911 - 97,2/263.4937
FAX: ~72/406-8023
TESTED FOR:
HAWKINS - WELWOOD HOMES, L.P.
DOWDEY, ANDERSON & ASSOCIATES
PIANO, TEXAS
REPORT OF FIELD
COMPACTION TESTS
DATE: 04/20105
PROJECT:
VILLAS AT LAKE VISTA PHASE ONE
(MASS GRADING ONLY)
COPPELL, TEXAS
OUR REPORT NO.: 04773-99
TEST DATA:
TEST DATE _ _~'~. ELEV. SOIL ID o;'lnuu~ MAXIMUM L~ IN Pr. ACE IN PLACE ~ ~MEN~
NO.~ NUMBER ~ ~ ~
1002 ~05 FG~.5 5 16.5 110.5 18.7 1~ 96 1-A
1003 ~0105 FG 5 16.5 110.5 17.5 109 99 1-A
10~ ~05 FG~.5 5 16.5 110.5 18.2 1~ ~ 1-A
1005 ~ ~0/05 FG 5 16.5 110.5 17.5 109 99 1-A
10~ 04~0105 FG~.5 5 16.5 110.5 19.9 105 95 1-A
1007 ~0/05 FG 5 16.5 110.5 19.0 108 98 1-A
1008 04~0/05 FG~.5 5 16.5 110.5 18.5 107
TEST LOCATION: BUILDING PAD
1002 20' S AND 20' E FROM THE NW CORNER OF BLOCK B, PAD 16
1003 ;~0' S AND 20' E FROM THE NW CORNER OF BLOCK B~ PAD 16
1004 20' S AND 20' E FROM THE NW CORNER OF BLOCK B, PAD 17
1005 20' S AND 20' E FROM THE NW CORNER OF BLOCK B~ PAD 17
1006 20' S AND 20' E FROM THE NW CORNER OF BLOCK B, PAD 18
1007 20' S AND 20' E FROM THE NW CORNER OF BLOCK Bt PAD 18
1008 20' S AND 20' E FROM THE NW CORNER OF BLOCK B, PAD 19
FILL
2 NATURAL SUBGRADE
3 LIME STABILIZED
4 CEMENT I~REATED
· A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
B PERCE~NT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Su~bmitted,
Geotechnical Engineedng /~ Construction Matedals Testing /~ Environmental Engineedng /~ Consulting
ALPHA TESTING, INC.
REPORT OF FIELD
COMPACTION TESTS
220~ Wisconsin St., Suite 100
~ Texas 7,5229
972/620-8911 - 972./263-4937 (Metro)
FAX.- 972/406.~8023
TESTED FOR: HAWKINS - WELWOOD HOMES, L.P.
DOWDEY, ANDERSON & ASSOCIATES
PIANO, TEXAS
DATE: 04/20/05
PROJECT:
VILLAS AT LAKE VISTA PHASE ONE
(MASS GRADING ONLY)
COPPELL, TEXAS
OUR REPORT NO.: 04773-99A
TEST DATA:
NO.DEFTH~ NUMBER % Pc; % Pc~ COMP.~CT~:~
1009 04/20/05 FG 5 16.5 110.5 17.9 110 99 1-A
1010 04/20/05 FG-.0.5 5 16.5 110.5 18.8 109 99 1-A
1011 04/20105 FG 5 16.5 110.5 17.0 110 100 1-A
1012 04/20/05 FG-0.5 5 16.5 110.5 18.2 107 97 1-A
1013 04/20/05 FG 5 16.5 110.5 18.2 109 99 1-A
1014 04/20/05 FG-O.5 5 16.5 110.5 17.8 109 98 1-A
1015 04/20/05 FG 5 16.5 110.5 18.9 108 98 1-A
TEST LOCATION: BUILDING PAD
1009 20' S AND 20' E FROM THE NW CORNER OF BLOCK B; PAD 19
1010 20' S AND 20' E FROM THE NW CORNER OF BLOCK B~ PAD 20
1011 20' S AND 20' E FROM THE NW CORNER OF BLOCK B, PAD 20
1012 20' S AND 20' E FROM THE NW CORNER OF BLOCK B, PAD 21
1013 20' S AND 20' E FROM THE NW CORNER OF BLOCK B, PAD 21
1014 20' S AND 20' E FROM THE NW CORNER OF BLOCK B, PAD 22
1015 20' S AND 20' E FROM THE NW CORNER OF BLOCK B, PAD 22
I. FILL * A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
2 NATURAL SUBGRAOE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3 LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respect~lly Submitted,
4 CEMENTTREATED D RETEST ~
CHARLES WILLIAMS
ALPHA T~STINO, INC
Geotechnical Engineedng /~7 Construction Matedals Testing //7 Environmental Engineedng /1~ Consulting
,ALPHA TESTIN¢~, INC.
REPORT OF FIELD
COMPACTION TESTS
2209 W1sco~a/n ~., 5U/re IOO
Dallas, Texo~ 75229
972/620-8911 - 97~7 (Mefro)
FAX: 972~406-~*q
TESTED FOR: HAWKINS - WELWOOD HOMES, L.P.
DOWDEY, ANDERSON & ASSOCIATES
PLANO. TEXAS
DATE: 04/20/05
PROJECT:
VILLAS AT LAKE VISTA PHASE ONE
(MASS GRADING ONLY)
COPPELL, TEXAS
OUR REPORT NO.: 04773-99B
TEST DATA:
TEST DATE _'~,~. ELEV. 8OIL ID o~mu,~u ~ L~ iN PU~E ~ ~ PEa:Em* COMMENT*
NO.D~PI~ ~,~ NUMBER % ~ % Pc~
1016 04/20/05 FG-0.5 5 16.5 110.5 16.7 110 99 1-A
TEST LOCATION: BUILDING PAD
1016 20' S AND 20' E FROM THE NW CORNER OF BLOCK B, PAD 23
4 CEMENT TREA~D D. REq[EST
Geotechnical Engineedng ~ Construction Materials Testing/~ Environmental Engineerfng /~ Consulting