Loading...
Villas at LV-LR050409 ALPHA TESTING, INC. ~ t4/Isconsln St., Suite 100 ~311os, Texas 7,5229 972/620-8911 - 972/263-4937 (Mefro) FAX: TESTED FOR: HAWKINS - WELWOOD HOMES, LP. DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 04~09~05 PROJECT: VILLAS AT LAKE VISTA PHASE ONE (MASS GRADING ONLY) COPPELL, TEXAS OUR REPORT NO.: 04773-90 TEST DATA: 934 04/09105 FG-0.5 5 16.5 110.5 19.3 106 96 1-A 935 04109105 FG 5 16.5 110.5 17.8 109 98 1-A 936 04/09/05 FG-O.5 5 16.5 110.5 18.7 107 97 1-A 937 04/09/05 FG 5 16.5 110.5 17.5 105 95 1-A 938 04/09105 FG-0.5 5 16.5 110.5 19.1 107 97 1-A 939 04/09/05 FG 5 16.5 110.5 18.3 108 98 1-A 940 04/09/05 FG-0.5 5 16.5 110.5 16.3 109 99 1-A TEST LOCATION: BUILDING PAD 934 15' N AND 30' E FROM THE SW CORNER OF BLOCK B, PAD 7 935 15' N AND 30' E FROM THE SW CORNER OF BLOCK B, PAD 7 936 15' N AND 30' E FROM THE SW CORNER OF BLOCK B, PAD 8 937 15' N AND 30' E FROM THE SW CORNER OF BLOCK B, PAD 8 938 15' N AND 30' E FROM THE SW CORNER OF BLOCK B, PAD 9 939 15' N AND 30' E FROM THE SW CORNER OF BLOCK B, PAD 9 940 15' N AND 30' E FROM THE SW CORNER OF BLOCK B~ PAD 10 I FILL 2 NATURA~ SUSGRADE 3 LIME STABILIZED 4 CEMENT TREATEO · A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~ C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Subm~ted, CHARLES WILLIAMS ALPHA 3~STING, INC. Geotechnical Engineering/~ Construction Materials Testing/~ Environmental Engineering /;~ Consulting ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Da~s, Texas 75229 972/620-8911 - 972/263-4937 CMefro) FAX: 972/40~8023 TESTED FOR: HAWKINS - WELWOOD HOMES, L.P. DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS PROJECT: VILLAS AT LAKE VISTA PHASE ONE (MASS GRADING ONLY) COPPELL, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 04/09~05 OUR REPORT NO.: 04773-90A TEST DATA: TEST ' DATE !__~.. ELEV~' SOIL ID O~llMUM MAXJMUM ~ IN Pr. ACE IN PLACE PERCENT COMMENT* MOIS~URE DRY ~3E~IT~ Mo~'ruR E DRY DENSITY COMPACTION NO.[:)EPTH ~h NUMBER % PC~ % PCF 941 04/09105 FG 5 16.5 110.5 18.9 106 96 1-A 942 04/09/05 FG-0.5 5 16.5 110.5 19.3 106 96 1-A 943 04/09105 FG 5 16.5 110.5 18.4 108 98 1-A 944 04109/05 FG-0.5 5 16.5 110.5 18.1 107 97 1-A 945 04109/05 FG 5 16.5 110.5 17.7 109 98 1-A 946 04/09/05 FG-0.5 5 16.5 110.5 17.0 109 98 1-A 947 04109/05 FG 5 16.5 110.5 19.5 105 95 1-A TEST LOCATION: BUILDING PAD 941 15' N AND 30' E FROM THE SW CORNER OF BLOCK B, PAD 10 942 15' N AND 30' E FROM THE SW CORNER OF BLOCK B, PAD 11 943 15' N AND 30' E FROM THE SW CORNER OF BLOCK B, PAD 11 944 15' N AND 30' E FROM THE SW CORNER OF BLOCK B, PAD 12 945 t5' N AND 30' E FROM THE SW CORNER OF BLOCK B, PAD 12 946 15' N AND 30' E FROM THE SW CORNER OF BLOCK B, PAD 13 947 15' N AND 30" E FROM THE SW CORNER OF BLOCK B, PAD 13 1 FILL 2 NATURAL SUBGRADE 3 LIME STABILIZED 4 CEMENT TREAIED · A IN PLACE PERCENT MOISTURE AND PERCENT COMPAC~rlON COMPLY WrTH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, D. RETEST ~~/~\ CHARLES WILLIAMS ALPHA TESTING, INC Geotechnical Engineering/g Construction Materials Testing/~ Environmental Engineering/~ Consulting ALPHA TESTINGS, INC. REPORT OF FIELD COMPACTION TESTS 220~ ~ St., Sulte Do#os, Texos 7522~ 972/~0.8911 - 972/203.,4~37 OVletro) FAX: 972/40d.,8023 TESTED FOR: HAWKINS - WELWOOD HOMES, L.P. DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS DATE: 04109105 PROJECT: VILLAS AT LAKE VISTA PHASE ONE (MASS GRADING ONLY) COPPELL, TEXAS OUR REPORT NO.: 04773-90B TEST DATA: TEST DATE _ _~. ELEV. SOIL ID O~rl~U¥ ~ L~ IN ~ IN PLACE PE~CEN/' COMMENT* NO.DEPTH ~,t NUMBER 948 04/09/05 FG-O.5 5 16.5 110.5 18.8 107 96 1-A TEST LOCATION: BUILDING PAD 948 15' N AND 30' E FROM THE SW CORNER OF BLOCK Br PAD 14 1 FILL 2 NATURAL SUBGRADE 3 LiME STASILIZED 4 CEMENT TREATED · A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY Wl~'l SPECIFICATIONS C. PERCENT iN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Subm~ed, CHARLES WILLIAMS ALPHA TESTING, INC Geotechnical Engineering/:b Construction Materials Testing/~ Environmental Engineering/~ Consulting