Villas at LV-LR050401ALPHA TESTING, INC. 2209 ~n~ln St., Suite I00 Ck~flas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: HAWKINS - WELWOOD HOMES, LP. DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 04/01/05 PROJECT: VILLAS AT LAKE VISTA pHASE ONE (Mau grading only) OUR REPORT NO.: 04773-79 COPPELL, TEXAS TEST DATA: 816 04/01/05 FG-3.5 4 23.5 96.5 30.8 89 93 1-A 817 04/01105 FG-3.0 2 21.0 103 25.2 97 95 1-A 818 04101~05 FG-2.5 2 21.0 103 23.3 100 97 1-A 819 04/01/05 FG-2.0 2 21.0 103 23.1 100 97 1-A 820 04/'01105 FG-1.5 4 23.5 96.5 28.5 92 95 1-A 821 04/01105 FG-1.0 4 23.5 96.5 30.4 91 94 1-A 822 04/01/05 FG-3.5 4 23.5 96.5 29.6 92 95 1-A TEST LOCATION: BUILDING PAD 816 !0' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 1 817 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 1 818 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 1 819 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 1 820 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 1 821 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 1 822 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 2 I FiLL 2 NATURAL SUBGRADE 3 LIME STABILIZED 4 CEMENT TREATED B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WiTH SPECIFICATIONS D RETEST · A iN PLACE PERCENT MOISTURE AN[3 PERCENT COMPACTION COMPLY WiTH SPECIFICATIONS Respectfully Submitted, CHARLES WILLIAMS ALPHA TESTING, INC Geotechnical Engineering /:h Construction Materials Testing /:b Environmental Engineering /~ Consulting ALPHA TESTING, INC. REPORT OF FIELD COMPACTION TESTS 2209 Wisconsin St., Suite 100 Do#os, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972~406~0~R TESTED FOR: HAWKINS - WELWOOD HOMES, L.P. DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS DATE: 04/01/05 PROJECT: VILLAS AT LAKE VISTA PHASE ONE (Mau grading only) COPPELL, TEXAS OUR REPORT NO.: 04773-79A TEST DATA: TEST DATE ___~_. ELEV. SOIL ID OPTIMUM MAXJMUM ~ IN FJ.N~E IN PLACE PERCEhT COMMENT* · MOISTURE DRY OENS~Y MO~PJRE DRY DENSITY COMP~TION NO.DEPTH ~,~.t NUMBER 823 04/01105 FG-3.0 4 23.5 96.5 29.1 91 94 1-A 824 04/01/05 FG-2.5 2 21.0 103 22.6 101 98 1-A 825 04/01105 FG-2.0 2 21.0 103 22.0 100 97 1-A 826 04/01/05 FG-1.5 2 21.0 103 24.6 98 95 1-A 827 04/01/05 FG-1.0 4 23.5 96.5 30.1 91 94 1-A 828 04/01/05 FG-4.0 4 23.5 96.5 29.6 91 94 1-A 829 04/01/05 FG-3.5 4 23.5 96.5 28.7 92 95 1-A TEST LOCATION: BUILDING PAD 823 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 2 824 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 2 825 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 2 826 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 2 827 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 2 828 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 3 829 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 3 1 FILL * A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WiTH SPECIFICATIONS 2 NATURAL SUBGRADE B PERCENT COMPACTION DOES NOT COMPLY WiTH SPECIFICATIONS 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, Geotechnical Engineering /~/7 Construction Materials Testing /~ Environmental Engineering /~ Consulting ALPHA TESTING, INC. 2209 Wisconsin ~t., Suite 100 ~ Texo8 7522~ 972/620-8911 - 972/263-4937 OVfeho) FAX: 972/406-8023 TESTED FOR: HAWKINS - WELWOOD HOMES, L.P. DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 04/01/05 PROJECT: VILLAS AT LAKE VISTA PHASE ONE (Mm grading only) COPPELL, TEXAS OUR REPORT NO.: 04773-79B TEST DATA: TEST DATE ~ ELEV. SOIL ID ommu~ MNGMUM !.~J IN I~l.t~E IN P!.AC~ PERCENT COMMENT* NO.~ NUMBER % ~CF % ~ 830 04/01/05 FG-3.0 4 23.5 96.5 29.8 90 93 1-A 831 04101105 FG-2.5 4 23.5 96.5 31.1 89 93 1-A 832 04101/05 FG-2.0 4 23.5 96.5 28.8 91 94 1-A 833 04101/05 FG-I.5 4 23.5 96.5 29.5 90 93 1-A 834 04/01/05 FG-1.0 4 23.5 96.5 28.5 93 96 1-A 835 04/01/05 FG-2.5 2 21.0 103 22.0 101 98 1-A 836 04/01/05 FG-2.0 2 21.0 103 24.5 97 94 1-A TEST LOCATION: BUILDING PAD 830 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 3 831 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 3 832 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 3 833 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 3 834 20' S AND 20' W FROM THE NE CORNER OF BLOCK B~ PAD 3 835 20' S AND 20' W FROM THE NE CORNER OF BLOCK B, PAD 4 836 !0' S AND 20' VV FROM THE NE CORNER OF BLOCK B, PAD 4 I FILL 2 NATURAL SUBGRADE 3 LIME STABILIZED 4 CEMENT TREATED · A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B PERCENT COMPACTION OOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN pLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, CHARLES WILLIAMS ALPHA TESTING, INC Geotechnical Engineering/~ Construction Materials Testing /~ Environmental Engineering /~ Consulting