Loading...
Villas at LV-LR050224ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 [Metro) FAX: 972/406-8023 TESTED FOR: HAWKINS - WELWOOD HOMES, L,P, CIO DOWDEY, ANDERSON & ASSOCIATES PLANO, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 02/24/05 PROJECT: VILLAS AT LAKE VISTA PHASE ONE COPPELL, TEXAS OUR REPORT NO.: 04773-8 TEST DATA: TEST DATE ~ELEV SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT* NO.DEPTH ~ NUMBER % PCF % PCF COMPACTION 9 02/24/05 FG-4.5 1 15.5 108.5 17.9 105 97 1-A 10 02/24/05 FG-4.5 1 15.5 108.5 17.7 105 97 1-A 11 02~24/05 FG-4.5 1 15.5 108.5 17.0 107 99 1-A 12 02/24/05 FG-4.5 1 15.5 108.5 18.2 105 97 1-A TEST LOCATION: BUILDING PAD 9 20' S AND 20' W FROM THE NE CORNER OF BLOCK A PAD 24 10 20' S AND 20' W FROM THE NE CORNER OF BLOCK A PAD 23 11 20' S AND 20' W FROM THE NE CORNER OF BLOCK A PAD 22 12 20' S AND 20' W FROM THE NE CORNER OF BLOCK A PAD 21 1 FILL 2 NATURALSUBGRADE 3 LIME STABILIZED 4 CEMENTTREATED · A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respecffulty Subm~ed D RETEST CHARLES WILLIAMS ALPHA TESTING, INC Geotechnical Eng/neenng / Construchon Materials Testing / Environmental Engineering / Consulting ALPHA TESTING, INC. 2209 Wisconsin St., ~ulte 100 ~ll~s, Texos 7522~ 972/620-8911 - 972/263-4~37 (Metro) FAX: 97~/406-8023 TESTED FOR: HAWKINS-WELWOOD HOMES, LP CIO DOWDEY, ANDERSON AND ASSOCIATES PLANO, TEXAS PROJECT: VILLAS AT LAKE VISTA PHASE I COPPELL, TEXAS IN-SlTU SWELL POTENTIAL DATE: 02/24/05 OUR REPORT NO.: 04773-7 TEST METHOD: ASTM D 4546 METHOD B TEST DATE SAMPLE MATERIAL INiTiAL FINAL HAND DRY UNIT TOTAL NO. SAMPLED LOCATION DESCRIPTION F~RCENT PERCENT PENETRO* WEIGHT PERCENT QC-1 02/24/05 BLOCK A PAD 21 (FG-4.0') BROWN SANDY CLAY 27.8 27.9 1.00 93.9 0.04% QC-2 02/24/05 BLOCK A PAD 8 (FG-4.0') BROWN CLAY 28.5 29.3 1.25 90.3 0.67% SPECIFICATIONS: MAXIMUM SWELL OF 1% OR LESS NOTES: Respectfully Sub~_tted, CHARLES WILLIAMS ALPHA TESTING, INC. Geotechnical Engineering #~ Construction Materials Testing /;~ Environmental Engineering ~7 Consulting ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: HAWKINS - WELWOOD HOMES, L.P. CIO DOWDEY, ANDERSON 8, ASSOCIATES PIANO, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 02/24/05 PROJECT: VILLAS AT LAKE VISTA PHASE ONE COPPELL, TEXAS OUR REPORT NO.: 04773-5 TEST DATA: TEST DATE ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAEI IN PLACE iN PLACE MOISTURE DRY DENSITY MOISTURE DRY E)ENSI"P( PERCENT COMMENT* NO.DEPTH '~ NUMBER % PCF % PCF COMPACTION 5 02/24/05 FG-4.0 1 15.5 108.5 17.2 107 98 1-A 6 02/24/05 FG-4.0 1 15.5 108.5 16.5 108 99 1-A 7 02124/05 FG-4.0 1 15.5 108.5 16.6 107 99 1-A 8 02/24/05 FG-4.0 1 15.5 108.5 17.2 107 98 1-A TEST LOCATION: BUILDING PAD 5 30' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 21 6 30' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 22 7 30' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 23 8 30' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 24 2 NATURALSUBGRADE 3 LIME STABILIZED 4 CEMENTTREATED · A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Subnl~ted, D RETEST CHARLES WILLIAMS ALPHA TESTING, INC Our tesl resui(s and reports are for the exclusive use of (he Client (ana their designated recipients on file in our office) and shall not De reproduced and/or distributed except with express approval of ALPHA Theuseofournameandtestresultsmustrece~veourwrl(tenapproval Test resultsandreporisapplyonly o ~esampestesedand/o observed a~darenotindicet~veoftnequahtiesof apparently idenbcal or similar specimens Geotechnical Engineenng / Construction Materials Testing / Environmental Engineering /, Consulting