Villas at LV-LR050311ALPHA TESTING, INC. 22C~ Wisconsin St,, Suite 100 DallOs, Texos 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: HAWKINS-WELWOOD HOMES, LP CIO DOWDEY, ANDERSON AND ASSOCIATES PLANO, TEXAS PROJECT: VILLAS AT LAKE VESTA PHASE I COPPELL, TEXAS IN-SlTU SWELL POTENTIAL DATE: 03/11/05 OUR REPORT NO.: 04773-41 TEST METHOD: ASTM D 4546 METHOD B TEST DATE SAMPLE MATERIAL INITIAL FINAL HAND DRY UNIT TOTAL NO. SAMPLED LOCATION DESCRIPTION PERCENT PERCENT PENETRO- V~EIGHT PERCENT MOISTURE MOISTURE METER (PCF) SWELL QC-11 03/11/05 BLOCK A PAD 18 (FG-4.0') BROWN SANDY CLAY 25.1 25.8 1.75 95.5 0.40% QC-12 03/11105 BLOCK A PAD 20 (FG-I.0') BROWN SANDY CLAY 27.1 27.5 1.50 97.4 0.37% QC-13 03/11/05 BLOCK D PAD 9 (FG-I.0') BROWN SANDY CLAY 25.2 25.8 1.75 97.8 0.48% QC-14 03/11/05 BLOCK D PAD 2 (FG~,.0') BROWN SANDY CLAY 25.5 25.8 1.50 98.1 0.43% QC-15 03/11/05 BLOCKDPAD3(FG-1.0') BROWN SANDY CLAY 27.1 27.5 1.50 96.0 0.36% SPECIFICATIONS: MAXIMUM SWELL OF 1% OR LESS NOTES: Respectfully Su.b_mitted, CHARLES WILLIAMS ALPHA TESTING, INC. Geotechnical Engineering /,' Construction Materials Testing /~ Environmental Engineering /~, Consulting ALPHA TESTING, INC. 2209 Wisconsin St,, Suite 100 Do#os, Texas 7522~ 972/620-8911 - 972/263-4937 [Metro) FAX: 972/406-8023 TESTED FOR: HAWKINS - WELWOOD HOMES, LP. CIO DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 03/11/05 PROJECT: VILLAS AT LAKE VISTA PHASE ONE COPPELL, TEXAS OUR REPORT NO.: 04773-39 TEST DATA: TEST ~ ELEV SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT MOISTURE DRY DENSITY blOISTURE DRY DENSITY COMMENT* NO DATE NUMBER % PCF % PCF COMPACTION 263 03111/05 FG-4.0 2 21.0 103 25.6 97 95 1-A 264 03~11105 FG-3.5 2 21.0 103 23.8 97 94 1-A 265 03111/05 FG-3.0 2 21.0 103 25.8 96 93 1-A 266 03111/05 FG-4.0 2 21.0 103 25.4 97 94 1-A 267 03/11/05 FG-3.5 2 21.0 103 24.8 97 94 1-A 268 03/11/05 FG-3.0 2 21.0 103 22.5 99 96 1-A 269 03/11/05 FG-4.0 2 21.0 103 22.9 99 96 1-A TESTLOCATION: BUILDING PAD 263 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 13 264 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 13 265 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 13 266 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 14 267 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 14 268 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 14 269 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 15 I FiLL 2 NATURALSUBGRADE 3 LIME STABILIZED 4 CEMENTTREATED · A INPLACEPERCENTMOISTUREANDPERCENTCOMPACTIONCOMPLYWITHSPECIFICATIONS B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS R es pecffully Su bmitt ed, D RETEST CHARLES WILLIAMS ALPHA TESTING, INC Geotechnical Engineering / Construction Matenals Teshng ,' Environmental Engineenng / Consulting ALPHA TESTING, INC. 220~ Wisconsin St,, Suite 100 Dallos, Texos 75229 972/620-8911 - 972/263-4937 [Metro) FAX: 972/406-8023 TESTED FOR: HAWKINS - WELWOOD HOMES, L.P. CIO DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 03/11/05 PROJECT: VILLAS AT LAKE VISTA PHASE ONE COPPELL, TEXAS OUR REPORT NO.: 04773-39A TEST DATA: TEST DATE DE~ SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT* NO. NUMBER % PCF % PCF COMPACTION 270 03/11/05 FG-3.5 2 21.0 103 25.0 97 94 1-A 271 03/11/05 FG-3.0 2 21.0 103 25.8 96 93 1-A 272 03/11/05 FG-4.0 2 21.0 103 23.2 98 95 1-A 273 03/11/05 FG-3.5 2 21.0 103 24.7 96 94 1-A 274 03/11/05 FG-3.0 2 21.0 103 23.3 97 94 1-A 275 03/11/05 FG-1.5 2 21.0 103 24.0 98 95 1-A 276 03/11/05 FG-I.0 2 21.0 103 22.9 99 96 1-A TEST LOCATION: BUILDING PAD 270 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 15 271 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 15 272 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 16 273 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 16 274 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 16 275 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 33 276 20' S AND 20' W FROM THE NE CORNER OF BLOCK A, PAD 33 1 FILL *A INPLACEPERCENTMOISTUREANDPERCENTCOMPACTIONCOMPLYWITHSPECIFICATIONS 2 NATURAL SUBGRADE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3 L~ME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, CHARLES WILLIAMS ALPHA TESTING, INC Geotechnical Engineering / Construction Materials Testing / Environmental Engineering /; Consulting