Loading...
Villas at LV-LR050325ALPHA TESTING, INC. 220{) Wisconsin St., Suite 100 Do~lOs, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: HAWKINS-WELWOOD HOMES, LP CIO DOWDEY, ANDERSON AND ASSOCIATES PIANO, TEXAS PROJECT: VILLAS AT LAKE VISTA PHASE I COPPELL, TEXAS IN-SITU SWELL POTENTIAL DATE: 03/25/05 OUR REPORT NO.: 04773-76 TEST METHOD: ASTM D 4546 METHOD B TEST DATE SAMPLE MATERIAL INITIAL FINAL HAND DRY UNIT TOTAL NO. SAMPLED LOCATION DESCRIPTION PERCENT PERCENT PENE3'RO- WEIGHT PERCENT MOISTURE MOISTURE METER {PCF) SWELL QC-39 03/25/05 BLOCK B PAD 11 (FG-I.0') TAN CLAY 20.9 21.4 1.75 96.6 0.28% QC-40 03/25/05 BLOCK C PAD 22 (FG-4.0') TAN CLAY 19.7 20.7 2.25 96.3 0.68% QC-41 03/25/05 BLOCK C PAD 25 (FG-3.0') TAN CLAY 21.3 21.7 1.75 96.4 0.35% SPECIFICATIONS: MAXIMUM SWELL OF 1% OR LESS NOTES: Respectfully Submitted, CHARLES WILLIAMS ALPHA TESTING, INC. Geotechnical Engineering /,~- Construction Materials Testing /~ Environmental Engineering /~ Consulting ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dolk~, Texas 75229 972/620-8911 - 972/263~7 (Metro) FAX: 972/406-602___3 REPORT OF FIELD COMPACTION TESTS TESTED FOR: HAWKINS - WELWOOD HOMES, L.P. DATE: 03/25/05 . , DOWDEY, ANDERSON & ASSOCIATES ~ PIANO, TEXAS PROJECT: VILLAS AT LAKE VISTA pHASE ONE (Ma~ grading only) OUR REPORT NO.: 04773-74 COPPELL, TEXAS TEST DATA: TEST DATE _~'~,~_. ELEV. ,SOIL ID (~11MUM MAXIMUM ~ IN PLACE IN Ft..~CE P~RCENT COMMENT* NO.DEPTH ~,,~ NUMBER ~, ;,cF % P~ 750 03/25/05 SG 4 23.5 96.5 29.6 93 96 2-A 751 03/25/05 SG 4 23.5 96.5 30.9 93 96 2-A 752 03/25/05 SG 4 23.5 96.5 28.5 94 98 2-A 753 03/25/05 FG-2.0 5 16.5 110.5 18.3 105 95 1-A 754 03/25/05 FG-I.5 5 16.5 110.5 17.7 105 95 1-A 755 03/25/05 FG-1.0 4 23.5 96.5 29.6 94 97 1-A 756 03/25/05 FG-2.0 5 16.5 110.5 17.6 105 95 1-A BUILDING PAD 750 20' N AND 30' W FROM THE SE CORNER OF BLOCK B, PAD 1 751 20' N AND 30' W FROM THE SE CORNER OF BLOCK B~ PAD 2 752 20' N AND 30' W FROM THE SE CORNER OF BLOCK Bt PAD 3 753 20' N AND 30' W FROM THE SE CORNER OF BLOCK B, PAD 16 754 20' N AND 30' W FROM THE SE CORNER OF BLOCK B, PAD 16 755 20' N AND 30' W FROM THE SE CORNER OF BLOCK B, PAD 16 756 20' N AND 30' W FROM THE SE CORNER OF BLOCK B, PAD 17 I FILL 2 NATURAL SUBGRADE 3 LIME STABILIZED 4 CEMENT TREATE[~ * A iNPLACEPERCENTMOISTUREANDPERCENTCOMPACTIONCOMPLYWITHSPECIFICATIONS B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WI~ SPECIFICATIONS Respectfully Submitted[. CHARLES WILLIAMS ALPHA TESTING, INC Geotechnical Engineering /~ Construction Materials Testing/:~ Environmental Engineering/:~ Consulting ALPHA TESTING, INC. 2209 W~con~n St,, Suite 100 Dc#los, Texos 75229 972/620-8911 - 972/263-4~37 CMe~o) FA~' 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR: HAWKINS - WELWOOD HOMES, L.P. DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS DATE: 03/25/05 PROJECT: VILLAS AT LAKE VISTA PHASE ONE (Mass grading only) COPPELL, TEXAS OUR REPORT NO.: 04773-74A TEST DATA: TEST DATE , SOIL ID MOISTURE DRY OEN~TY MOISTURE DRY DENSITY COMPACTION NO. NUMBER ~ ~CF % ~CF 757 03/25105 FG-1.5 5 16.5 110.5 18.6 106 95 1-A 758 03/25105 FG-1,0 5 16.5 110.5 18.3 106 96 1-A 759 03/25105 FG-2.0 5 16.5 110.5 18.0 105 95 1-A 760 03/25/05 FG-1.5 5 16.5 110.5 19.0 105 95 1-A 761 03/25/05 FG-1.0 4 23.5 96.5 30.1 93 97 1-A 762 03/25/05 FG-2.0 5 16.5 110.5 20.7 103 94 1-A 763 03/25/05 FG-1.5 4 23.5 96.5 30.2 92 96 1 -A )CATION: BUILDING PAD 757 20' N AND 30' W FROM THE SE CORNER OF BLOCK B, PAD 17 758 20' N AND 30' W FROM THE SE CORNER OF BLOCK B, PAD 17 759 20' N AND 30' W FROM THE SE CORNER OF BLOCK B, PAD 18 760 20' N AND 30' W FROM THE SE CORNER OF BLOCK B, PAD 18 761 20' N AND 30' W FROM THE SE CORNER OF BLOCK B, PAD 18 762 20' N AND 30' W FROM THE SE CORNER OF BLOCK B, PAD 19 763 20' N AND 30' W FROM THE SE CORNER OF BLOCK B, PAD 19 I FILL 2 NATURAL SUBGRADE 3 LIME STABILIZED 4 CEMENT TREATED · A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WiTH SPECIFICATIONS Respectfully Submitted, CHARLES WILLIAMS ALPHA TESTING, INC Geotechnical Engineering/~ Construction Materials Testing/~ Environmental Engineering /~ Consulting ALPHA TESTING, INC. ~209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972.~406-8023 TESTED FOR: HAWKINS - W£LWOOD HOMES, L.P. DOWDEY, ANDI::RSON & AssOCIATE"$ PIANO, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 03~25~05 PROJECT: VILLAS AT ~KE VISTA PHASE ONE (Mass grading MN) COPPELL, TEXAS OUR REPORT NO.: 04773-74B TEST DATA: TEST DATE __'~_.. ELEV. SOIL ID O~MUM MAXIMUM LAB IN pLACE IN P!..~E PERCENT COMMENT* NO.DEPTH '~ NUMBER % PcF % PCF 764 03/25/05 FG-1.0 4 23.5 96.5 28.5 95 98 1-A 765 03/25/05 FG-1.5 4 23.5 96.5 29.4 92 95 1-A 766 03/25/05 FG-1.0 4 23.5 96.5 28.6 91 95 1-A 767 03/25/05 FG-1.5 4 23.5 96.5 29.5 94 97 1-A 768 03/25/05 FG-1.0 4 23.5 96.5 30.1 91 94 1 -A 769 03/25/05 FG-1.5 4 23.5 96.5 29.3 95 98 1-A 770 03/25105 FG-1.0 4 23.5 96.5 29.8 91 94 1-A BUILDING PAD 764 20' N AND 30' W FROM THE SE CORNER OF BLOCK B, PAD 19 765 20' N AND 30' W FROM THE SE CORNER OF BLOCK A, PAD 1 766 20' N AND 30' W FROM THE SE CORNER OF BLOCK A, PAD 1 767 20' N AND 30' W FROM THE SE CORNER OF BLOCK A, PAD 2 768 20' N AND 30' W FROM THE SE CORNER OF BLOCK A, PAD 2 769 !0' N AND 30' W FROM THE SE CORNER OF BLOCK A, PAD 3 770 20' N AND 30' W FROM THE SE CORNER OF BLOCK A, PAD 3 FILL 2 NATURAL SUBGRADE 3 LIME STABILIZED 4 CEMENT TREATED * A iNPLACEPERCENTMOISTUREANDPERCENTCOMPACTIONCOMPLYWITHSPECIFICAT~ONS B PERCENT COMPACTION OOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Subm~d, CHARLES WILLIAMS ALPHA TESTING, INC Geotechnical Engineering /~ Construction Materials Testing/~ Environmental Engineering /~ Consulting ALPHA TESTING, INC. ~209 Wisconsin St., Su#e 100 Dallas, Tex~ 75229 972/620-8~11 - 972/263-4~37 (Metro) FAX: 972/406-8023 TESTED FOR: HAWKINS - WELWOOD HOMES, L.P. DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 03/25/05 PROJECT: VILLAS AT LAKE VISTA PHASE ONE (Mass grading o~ly) OUR REPORT NO.: 04773-74C COPPELL, TEXAS TEST DATA: TEST DATE __~_..ELEV SOIL ID C~VT1MUM MAXIMUM [AB IN Pt~C£ IN PLACE PERCENT COMMENT* NO.DEPTH ~ NUMBER % PcF % PcF 771 03/25/05 FG-2.0 4 23.5 96.5 30.0 92 95 1-A 772 03/25/05 FG-I.5 4 23.5 96.5 31.2 92 95 1-A 773 03/25/05 FG-I.0 4 23.5 96.5 31.5 89 93 1-A 774 03/25/05 FG-2.5 4 23.5 96.5 29.6 91 94 1-A 775 03/25/05 FG-2.0 4 23.5 96.5 31.3 91 94 1-A 776 03/25/05 FG-1.5 4 23.5 96.5 28.7 91 94 1-A 777 03125105 FG-1.0 4 23.5 96.5 28.7 93 96 1-A TEST LOCATION: BUILDING PAD 771 20' N AND 20' W FROM THE SE CORNER OF BLOCK A, PAD 4 772 20' N AND 20' W FROM THE SE CORNER OF BLOCK A, PAD 4 773 20' N AND 20' W FROM THE SE CORNER OF BLOCK A, PAD 4 774 20' N AND 20' W FROM THE SE CORNER OF BLOCK A~ PAD 5 775 20' N AND 20' W FROM THE SE CORNER OF BLOCK A, PAD 5 776 20' N AND 20' W FROM THE SE CORNER OF BLOCK A, PAD 5 777 20' N AND 20' W FROM THE SE CORNER OF BLOCK A, PAD 5 FILL 2 NATURAL SU~GRADE 3 LIME STABILIZED 4 CEMENT TREA3~ED · A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS S PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, CHARLES WILMAMS ALPHA TESTING, INC. Geotechnical Engineering /.~ Construction Materials Testing /~ Environmental Engineering /~ Consulting ALPHA TESTING, INC. ~ Wisconsin St., Suite Oollas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: HAWKINS - WELWOOD HOMES, L.P. DOWDEY, ANDERSON & ASSOCIATES PIANO, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 03/25/05 PROJECT: VILLAS AT LAKE VISTA PHASE ONE (Mass grading only) COPPELL, TEXAS OUR REPORT NO.: 04773-74D TEST DATA: TEST DATE ~ELEV SOIL ID O~nUUM MAXIMUM ~ iN Pt~CE IN PLAC,~ MOISTURE DRY DRN$1~'Y MOISTURE DRY DENSnY PERCENT COMMENT* NO.DEPTH~ NUMBER % t=CF % PCF COMPACllON 778 03/25/05 FG-3.0 4 23.5 96.5 30.9 93 96 1-A TEST LOCATION: BUILDING PAD 778 20' N AND 20' W FROM THE SE CORNER OF BLOCK A, PAD 6 1 FILL 2 NATURAL SUBGRADE 3 LIME STABILIZED 4 CEMENT TREATED IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS PERCENT COMPACTION DOES NOT COM PLY WITH SPECIFICATIONS PERCENT IN PLACE MOISTURE OOES NOT COMPLY WITH SPECIFICATIONS Respectfu~¥ Submitted, CHARLES WILLIAMS ALPHA ~STING, INC Geotechnical Engineering ~ Construction Materials Testing ~ Environmental Engineering/~7 Consulting