Loading...
KFC & Pizza Hut-CS 890420 CITY OF COPPELL PLANNING& ENGINEERING DEPAR~ N~/ Date: April 20, 1989 STAFF REj PLANNING & ENGINEERING DEPARTMENT~'/ LOCATION: South-of Sandy Lake Road on De~t~n T4p Ro~a~--~ext o~the existing McDonald's restaurant. ~ ],l_~3Az~'~_ REQUEST: Approval of a final pla~C-~ APPLICANT: Kentucky Fr led Chicken~ St~%%RY: Staff has..x~vi-~-th--~-~bject Final Plat and Construction /Plans, ~d requ a ..... ' ed in the letter from ~Ginn, lh~., dated April 13, 1989,_~ agreed to be complied with by the a is ime, and the necessary changes be made prior ~_~to City Council. ALTERNATIVES: ATTACHMENTS: KENTFIN 1. Approve as submitted. Approve with the condition that above referenced letter be complied with, prior to the May 9, 1989 City Council meeting. 3. Deny ~, Inc., 1. Final Flat 2. Letter from Ginn, GINN, INC. April 13 ~ 19~9 Mr. Russ yle, P.E. City of ~oppell P.O. Bg~ 478 Coppe 1/1, TX 75019 Re: Kentucky Fried Chicken Zoning Request and Final DRC-Engineering CONSULTING ENGINEERS Plat/Construction Plans Dear Mr. Doyle: We have reviewed the above referenced project and offer the following comments. Regarding the Zoning Change Request from Retail to Commercial- Special Use Permit with Drive-Thru, we suggest the monument sign not be indicated on the Site Plan at this time under the SUP but rather be handled as a separate issue. Also, a Variance Request should be added on the Site Plan for a north-drive access to be allowed off of Denton Tap Road. These site Plan revisions can be made conditions of any motion when considering this issue at the Planning & Zoning meeting with the revisions being requested to be made prior to the Zoning Change Request going forward to City Council. Regarding the Final Plat we have the following comments. 1. Applicant should re-verify the square footage and acreage calculated for this site. Per the City's Comprehensive Floodplain Management Ordinance, paragraph 4 oii pa~e 34, a Floodplain Permi~ note needs to be added to the plat. This site, however, is not within the limits of any existing floodplain or floodway, therefore, a permit number for development would not be applicable. Any proposed fire lanes outside the limits of the platted site need to be dedicated by separate dedication instruments. These instruments should be executed, notarized and provided to the City prior to the Final Plat being submitted to the City Council for consideration. The floodplain note shown on the Final Plat is not required to be on the plat, and thus, can be deleted. 17103 Preston Road · Suite 100 · LB 118 · Dallas, Texas 75248 · Phone 214/248-4900 The need for the Variance Request for a north-drive is due to the Sub-Division Ordinance requiring, for a 35 mph roadway, 100 feet be provided between drives and for a 40 mph roadway 120 feet be provided. Approval of the variance would allow a driveway spacing of only 72 feet approximately. Circulation will still exist without this drive via the common access drive between McDonalds and this site. Please reference the attached excerpts from the Sub- Division Ordinance. Regarding the Construction Plans we offer the following comments. 1. Power feed from TU Electric ~hou~d be~an%~n~grou~e~d~A from Denton Tap. ~.A.~--~ ~ "~ U'-~, ~ 2. Site should 'sewer (sanitary) from tke rear as per the original Preliminary Engineering plan· This will alleviate the need for the applicant to open cut approximately 65 feet across the new Denton Tap Road pavement (3 southbound lanes, median and I northbound lane)· Public safety and reduced liability will be better assured for both the applicant and the City with this requested revision· The 2" domestic water tap should be in the same trench as the fire hydrant lead tap if the new Denton Tap Road concrete pavement is existing at the time the site develops. This will alleviate the need for 2 street cuts or tunnels (whichever is required by Public Works) and only require 1. Ail pavement shall be required to be 6" thick, 3000 psi at 28 days with a 6" lime stabilized subgrade (6%). This includes any drives. Also, no cushion sand is allowed between the subgrade and the pavement. Applicant must submit written permission from the property owner prior to the City allowing any pavement to be placed outside either the platted area or outside any fire lane easement boundaries. This shall be required prior to approval cf the construction plans. Please call if you have any questions. Sincerely,,. /) Kevin Peiffer,~. E. / KP/dsp '-- CC: Robert Howman, Ayres Assoc. DRC File 89305 I II II II II II II ! II II II ! II DRIVEWAY RADIUS A]! d~$vewoys intersecting dedicated streets iha]! be built with a circu]a~ curb ~ad~us connecting the six-inch ~aised cu~"b of the ~oadwoy to the design width pavement of the d~tvewoy. D=lveways sha]! be located fas enough ¢~om the tnte~to~ p~ope~ty line to permit the curb ~adlus to fo]] entirely tn f~ont of the sub~ect p~ope~ty. ?he City Enginee~ she]] approve the d~tve~y widths and d~iveway ~adlus et the time of site plan ~evtew p~evtous to ]~suence of any building permit. In o~de~ that the def$nStion of the location of the edge of pavement fo~ the thoroughfare may be maintained, d~lvewey ~adJi shall always be designed to become tangent to the street curb line. Two-way d~]veways shall always be designed to intersect the street et o 90-degree angle. One-way d~$veways may be designed to intersect a street at a minimum ~5-deg~ee angle. D~]VE~A¥ SPACING AND LOCAT]0N The spacing and location of d~tveweys shall be ~e]eted to adjacent d:tveways and nearby st=eat intersections. The spacing between d~Jveways shall be dependent upon the speed limit of the thoroughfare and a~e ~ecommended os fo]]o~s: (see Figure 21 ~0 ~5 ~5 65 30 90 35 ~00 ~0 3~0 ~G 350 50 ~00 Appendix A II II II II II II ! spacings shown above. Spacings between driveways will be measured along the pcope=t7 line ¢com the edge of one dciveway the next driveway and not f~om centerltne with no f~ee ~tght-tu~n lane, the minimum distance A, Figure 2, of a d=ive- way f~om the intersection of mo)or tho~oughCares shall be fifty feet and the minimum distance A, Figure 2, of a driveway from the lntecsectton of minor thocoughfoces shall be thlcty feet. General cequlrements ¢oc delve- way design are shown in Ftgu=e 2. A summe~-y of d=tveway width, radius and angle =equt=ements is given in Table TABLE SU~4~ARY OF REQU]RENENTS RESZDENT[AL Minimum 12 Maximum RIGHI TURN RADIUS [RI Minimum 5 Maximum ONE-WAY [:~]¥E ANGLE Minimum (deg~eesl COMMERCIAL II'~DUSTRIAL 20 (15 1-way) 20 30 ~0 10 15 20 25 MISCELLANEOUS THOROUGHFARE STANDARDS A. Specific details shall be as shown fo= the City of Coppe]l. in the Design Standards Appendix A ~3 LEG£HD A-Distance bock from Intemection R - Driveway fgdlus W- Approach width D- Distonce between- driveways A _ _ W _ 50' Minimun FIGURE 2 -- GEOMETRIC FOR DRIVEWAY DESIGN II