Loading...
KFC & Pizza Hut-CS 890413 GINN, INC. April 13, 1989 . M~. Russe/~yle, P.E Clty of~oppell P.O. B~ 478 ~ ~entucky Fried Chicke~ zunin9 RequeS= anu DRC-Engineering CONSULTING ENGINEERS Plat/Construction Plans Dear Mr. Doyle: We have reviewed the following comments. above referenced project and offer the Regarding the Zoning Change Request from Retail to Commercial- Special Use Permit with Drive-Thru, we suggest the monument sign not be indicated on the Site Plan at this time under the SUP but rather be handled as a separate issue. Also, a Variance Request should be added on the Site Plan for a north-drive access to be allowed off of Denton Tap Road. These Site Plan revisions can be made conditions of any motion when considering this issue at the Planning & Zoning meeting with the revisions being requested to be made prior to the Zoning Change Request going forward to city Council. Regarding the Final Plat we have the 1. Applicant should re-verify the calculated for this site. following comments. square footage and acreage e Per the city's Comprehensive Floodplain Management Ordinance, paragraph 4 o~ page 34, a Floodplain Permi~ note needs to be added to the plat. This site, however, is not within the limits of any existing floodplain or floodway, therefore, a permit number for development would not be applicable. Any proposed fire lanes outside the limits of the platted site need to be dedicated by separate dedication instruments. These instruments should be executed, notarized and provided to the city prior to the Final Plat being submitted to the city Council for consideration. The floodplain note shown on the Final Plat is not required to be on the plat, and thus, can be deleted. 17103 Preston Road · Suite 100 · LB 118 · Dallas, Texas 75248 · Phone 214/248-4900 5e The need for the Variance Request for a north-drive is due to the Sub-Division Ordinance requiring, for a 35 mph roadway, 100 feet be provided between drives and for a 40 mph roadway 120 feet be provided. Approval of the variance would allow a driveway spacing of only 72 feet approximately. Circulation will still exist without this drive via the common access drive between McDonalds and this site. Please reference the attached excerpts from the Sub- Division Ordinance. Regarding the Construction Plans we offer the following comments. 1. Power feed from TU Electric should be an underground feed from Denton Tap. Site should 'sewer (sanitary) from the rear as per the original Preliminary Engineering plan. This will alleviate the need for the applicant to open cut approximately 65 feet across the new Denton Tap Road pavement (3 southbound lanes, median and i northbound lane). Public safety and reduced liability will be better assured for both the applicant and the City with this requested revision. The 2" domestic water tap should be in the same trench as the fire hydrant lead tap if the new Denton Tap Road concrete pavement is existing at the time the site develops. This will alleviate the need for 2 street cuts or tunnels (whichever is required by Public Works) and only require 1. Ail pavement shall be required to be 6" thick, 3000 psi at 28 days with a 6" lime stabilized subgrade (6%). This includes any drives. Also, no cushion sand is allowed between the subgrade and the pavement. Applicant must submit written permission from the property owner prior to the City allowing any pavement to be placed outside either the platted area or outside any fire lane easement boundaries. This shall be required prior to approval of the construction plans. Please call if you have any questions. cc: Robert Howman, DRC File 89305 Ayres Assoc. I I i I i i i I ! i ! ! DRIVEWAY RADIUS All d~tveways tnte~sec%lng dedicated streets shall be built with o cJ~culo~ curb =odtus connecting the six-inch ~oised curb of the ~oodwoy to the destgn wtdth pavement o¢ the d~iveway, D~tveways shall be located fo~ enough f~om the tnte~o~ p~ope~ty line to permit the curb ~odtus to fall entirely in f~ont of the sub~ect p~ope~ty. ?he City Engtnee~ she]! approve the d~tveway widths and d~tveway ~adlus at the time of site plan ~evtew p~ev~ous to issuance of any building permit. ]n o~de~ that the definition of the location of the edge of pavement fo~ the thoroughfare may be maintained, d~tvewoy ~adti sha]! always be designed to become tangent to the street curb line. ~wo-woy d~tveways shall always be designed to intersect the street at o 90-degree angle. One-way d~iveways may be designed to intersect a street at o minimum 4S-degree angle. D~]VEWAY SPACING AND LOCA?ION The spacing and location of d~tveways shall be ~elated to ad)acent d~iveways and nearby street intersections. The spacing between d~iveways shall be dependent upon the speed limit of the thoroughfare and a~e ~ecommended as follows: (see Figure 2l 25 ~5 30 90 35 100 40 120 SO 200 Appendtx A II I II II I I I Minimum spacing shall not be mo:e than ten feet less than the :ecommended spacings shown above. Spacings between d:iveways will be measu:ed along the p:ope:ty line f:om the edge of one d:iveway to the closest edge of the next d:Jveway and not f:om cente:ltne to cente:line. At trite:sections with no f:ee :ight-tu:n ]one, the minimum distance A, Figu:e 2, of a d:ive- way f:om the inte:section of ma)o: tho:oughfa:es shall be fifty feet and the minimum distance A, Figu:e 2, of a d:tveway f:om the inte:section of mina: tho:oughfa:es sha)l be thi:ty feet. Gene:al :equi:ements fo: d:tve- way design ate shown in Figu:e 2. A summa:y of dtiveway width, :adius and angle :equi:ements is given tn Table 11. TABLE 11 SUI~4~RY OF REGU]REMENTS RES]DENT]AL WIDTH Minimum Maximum RIGH1 TURN RADIUS IR) Minimum Maximum 15 ONE-WAY DRlVE ANGLE Minimum (deg:ees! ~RCIAL INDUSTRIAL 20 (15 1-wayl 20 30 40 10 15 20 25 MISCELLANEOUS THOROUGHFARE STAM~ARDS A. Specific details shall be as shown fo: the City of Coppell. in the Design Stonda:ds Appendix A 13 LEGEND A o Distance bock from Itffersection R - Driveway radius W- Approoch width D- DIstonce between' drtvowc~ys ! II II II II ! A ~ 50' Minimun W FIGURE ~) -- GEOMETRIC FOR DRIVEWAY DESIGN II