Loading...
SS9901-LR051018Construction Materials Testing and Environmental Consulting Texas CMT, Inc. 10044 Monroe Drive Dallas, Texas 75229 (214) 352-6957 Fax (214) 352-6972 www .texascmt.com REPORT OF CONCRETE MIX OBSERVATION Report Date: Client: Prqiect: Contractor: Concrete Supplier and Plant: Location of Placement: October 18, 2005 Date Concrete Placed: October 10, 2005 City of Coppell Deforest & Sandy Lake Wastewater Lift Stations: Project SS 99-01 Can-Fer Construction Southern Star 27 Slab Standard 6"xl 2" Area 28.27 Square Inches Concrete Report No.: 18 Project No.: 205-0126 MATERIALS so.r¢~ SSD [latch Wts OBSERVATION DATA Description (Lbs/CuYd) Mix Number: 7503 Time Sample Batched: Cement: Time Sampled: Sample Location: Fly Ash: Tmck/l'icket No: Coarse Aggregate: Temperature: lutermediate Aggregate: Ambient Range: 93°F Fine Aggregate: Concrete Range: 91 °F Slump Pamge (inches): 6V:" Admixtures: Weather Conditions: Clear I Time Started: 01:30 pm 2 Time Completed: 04:15 pm Added Water: 0 gallons Sample Air Content (%): 3% Total Cubic yards Placed: 10 01:46 pm 02:45 pm Bottom of pit - south area 0031/959373 Required Stren~h {Lbs./sq.in. 4000 Number Slump (in ? (Days~ Tested {LbsI ~Lbs/Sq In ~ DLS 69 7 10/t 7/05 134,480 4,760 DLS 70 28 11/07/05 DLS 71 28 11/07/05 DLS 72 H HOLD Remarks and/or Distribution: * Foreman informed of slump CC¸ Mr. Rick O'Dell - City of Coppell Mr. Todd C. Hoff - Canfer Construction Co. Ms. Erika K. Cooper - Turner, Collie & Braden Mr. Bobby Bart - Onsite cell: 469-556-6469 Construction Materials Testing and Environmental Consulting Texas CM% Inc, 10044 Monroe Drive Dallas, Texas 75229 (214) 352-6957 REINFORCING STEEL PLACEMENT Report Date: October 18, 2005 Client: City of Coppell Project DeForest & Sandy Lake Wastewater Lift Stations: Project - SS 99-01 Reinforcing Steel Observation Visual Observation Identification Method of Test Results Fax (214) 352-6972 Test Date: October 13, 2005 General Report No.: 7 Project No.: 205-0126 On October 13, 2005 reinforcing steel was observed at the following locations: Wet well baffle wall & south portion of baffle wall 1. Some dowels ~ the SE comer are missing 2. Comer bars around opening are not placed www .texascmt.com Pa~;e 1 of 1 The following discrepancies were noted and called to the attention of superintendent The above discrepancies will be checked before pour Technician: MR Mr. Rick O'Dell - Ciiy of Coppell Mr. Todd C. Hoff - Can£er Construction Co. Ms. Etika K. Cooper - Turner, Collie & Braden Mr. Bobby Bart - Onsite cell: 469-556-6469