SS9901-CS050819AUG 19 2005 11:09 FR TURNER COLLIE& BRADENg?2 ?55 5002 TO 99?250455?0 P.02×02 TCB i AECOM Turner Gollie & Draden '17300 Dallas ~arkway, Suite 10'lC), Dallas, Texas 75248 T 972.735.3000 F 972.735.3001 www.tcb aecom corn Facsimile Please deliver to From Name Charlie Ferrara Name Firm Can-Fer Construction Direct line Fax number 972-484-4223 Date transmiffed Phone number 972-484-4344 Number of pages including cover Subject Coppell DeForest & Sandy Lake Lift Stations Project reference 05213I 124.0001.04000A103 Erika Cooper 972-735-3056 August19,2005 Message Charlie, This fax Station. is in response to questions regarding construction of the DeForst Lift 1. Does the reinforcing for the beams (as shown in Section B on Sheet DS-l) need to be tied to the wall reinforcing? It is not necessary for the beam reinforcing to be tied to the wall reinforcing unless the contractor wishes to do so to hold the bars in place during the concrete placement. However, it is necessary for the beam reinforcement to extend into the wall a minimum of 2'-3". 2. Can the valve vault walls and wet well walls be done in a single pour? The joint at the interface of the valve vault walls and the wet well walls (shown on Sheet DS-2) cannot be eliminated. Without this joint, the wall would tend to crack at that location due to the fact that wet well walls are much more massive than the valve walls. TOTAL PAGE.02 **