Loading...
Magnolia Village-LR010829Professional Inline Services, Inc. P.O. Box 118095 Carrollton, TX 75011-8095 Office 972-939-2600 Fax 214-731-0535 CONTRACTORS NAME: CITY OF: INSPECTS- INSPECTION FIRM: Professional Inline Services, Inc. OPERATOR~ P.O. Box 118095 Carrollton, TX 75011-8095 PROFESSIONAL INLINE SERVICES, INC, Office 972-939-2600 Fax 214-731-0535 Mobile 214-534-9942 Beeper214-249-2309 LOW PRESSURE A/R rEST FOR GRAVITY SANITARY SEWER Test Procedure: Each section of sewer shall be tested between SUcessive manholes. Air shall be introduced into the pipeline until 4.0 psi gauge pressure has been reached. At ~nat time the flow of air shall be reduced and the internal air pressure shall be maintained oe~een 3 5 and 4.5 psi gauge for at least two(2) minutes to allow the air temperature to come to equilibrium with the temperature of the pipe wall~. Pressure in the pipe shall be constantly monitored by a gauge and hose arrangement separate from the hose used to introduce air the hne Pressure in the pipe shall not be allowed to exoeed 5 psi. After the temperature has stabilized and no air leaks at the plugs have been found, the air pressure shall be used 1o delermine the time lapse required for lhe air pressure to drop to 2.5 psi gauge. the time lapse required for the air pressure to decrease from 3.5 to 2.5 psi exceeds thai shown in fha following lab e. tfte pipe shall be presumed to be within acceptable limits for leakage time lapsed is less than that shown in the table, the contractor shall make corrections to reouce the leakage lo acceptable limits, Line Information I I I JTest Results lair Test IMa.drel Line Station Io Station Pipe Size LF.Tested Time Passed? Passed? Proiect C ~' n~.~' Inspectors Full Name ~m . - ' Job# PROFESSIONAL INLINE SERVICES, INC. P.O. BOX 118095 CARROLLTON, TX. 75011 (972)939-2600 LOG REPORT 08-28-2001 CONTRACTOR:LLANO INSPECTOR :GARRETH.CAMPBEL OPERATOR :RUBEN.R CONTRACT #:NONE TAPE # :1 PAGE # :1 PIPE INFORMATION MH STATION # :0+00 MM STATION # :2+61(PLUG) PIPE TYPE :PVC PIPE SIZE :8" DIRECTION :UP GRADE :0.40% LINE # :A JOB NAME:MAGNOLIA RETAIL CENTER LOCATION :COPPELL,TX CONDITION :NEW FOOTAGE: 0.0 Ft TIME OF DAY: 8:17am FAULT OR COMMENTS: M.H STA.0+00 LINE-A 251.9 Ft 8:26am STOPPED AT STA.2+61(PLUG) END OF LINE-A PROFESSIONAL INLINE SERVICES, INC. P.O. BOX 118095 CARROLLTON, TX. 75011 (972)939-2600 LOG REPORT 08-28-2001 CONTRACTOR:LLANO INSPECTOR :GARRETH.CAMPBEL OPERATOR :RUBEN.R CONTRACT #:NONE TAPE # :1 PAGE # :2 PIPE INFORMATION MH STATION # :0+00 MH STATION # :I+02(PLUG) PIPE TYPE :PVC PIPE SIZE :8" DIRECTION :UP GRADE :0.40% LINE # :B JOB NAME:MAGNOLIA RETAIL CENTER LOCATION :COPPELL,TX CONDITION :NEW FOOTAGE: 0.0 Ft TIME OF DAY: 8:33am FAULT OR COMMENTS: M.H STA.0+00 LINE-B 98.4 Ft 8:37am STOPPED AT END OF PLUG AT STA.i+02 END OF LINE-B PROFESSIONAL INLINE SERVICES, INC. P.O. BOX 118095 CARROLLTON, TX. 75011 (972)939-2600 LOG REPORT 08-28-2001 CONTRACTOR:LLANO INSPECTOR :GARRETH.CAMPBEL OPERATOR :RUBEN.R CONTRACT #:NONE TAPE # :1 PAGE # :3 PIPE INFORMATION MH STATION # :0+00 MH STATION # :TO STB/OUT.E PIPE TYPE :PVC PIPE SIZE :6" DIRECTION :UP GRADE :N/A LINE # :S.S EAST. JOB NAME:MAGNOLIA RETAIL CENTER LOCATION :COPPELL,TX CONDITION :NEW FOOTAGE: TIME OF DAY: FAULT OR COMMENTS: 0.0 Ft 8:47am M.H STA.0+00 LINE-S.S EAST. 85.6 Ft 8:50am STOPPED AT PLUG AT END OF LINE-S.S EAST END OF SURVEY.