Loading...
Rozas Addn-LR0508127636 Pebble Drive Fort Worth, Texas 76118 Client: Tri-Star Construction Project: Dr. Roza's Office Coppell CMJ Report No.: 548-5051-021 Report Date: 08/12/2005 Concrete Compression Test Report ENGINEERING, [NE. Tel: (817) 284-9400 Fax: (817) 589-9993 Report Distribution: (1)TH-Star Construction (1) City of Coppell Specifications Teat Data Strength 4000 psi @ 28 Days Placement Date 07/28/2005 Slump 3 in min 5 in max Sampred By Richard Jones Air Content 3 % min 6 % max Weather Cloudy/Slight Breeze Concrete Temperature n/a Supplier/Mix TXI/517 Ambient Temperature n/a Air Content Method ASTM C231 Ticket Number: 89871 Time Batched: 08:05 Time SamPled: 08:50 Slump: 3.5 in Air Content: 4.4 % Unit Weight: N/A Concrete Temperature: 87° F Ambient Temperature: 75° F Yardage (c.y.): 120/200 Placement Location: Paving: East parking and fire lane Sample Location: From southern most southeast comer of slab. 40 feet south, 130 feet east Concrete Compression Test Results ind ,~,ge Max Load Area Stren~th Fracture Set # Cyl#er Test Date (days) (lbs. fome) (sq.in.) (psi] Type 02 DRO07280505 08/04/2005 7 02 DR007280506 08/25/2005 28 02 DRO07280507 08/25/2005 28 02 DRO07280508 Hold Normal cylinder size: 6" x 12" 101520 28.27 3590 Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, Cl 43, Cl 72, C1064. and C617 or C1231. 10 Gallons of Water Added On-Site by the Contractor do not pertain to any other samples, items or areas regardless of similarity. Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc, o] Page 2 of 3 C M J ENGINEERING, INC. 7636 Pebble Drive For~ Worth, Texas 76118 Client: TH-Star Construction Project: Dr. Roza's Office Coppell Concrete Compression Test Report Tel: (817) 284-9400 Fax: (817) 589-9993 Report Distribution: (~1) Tri-Star Construction (1) City of Coppell CMJ Report No.: 548-5051-O21 Report Date: 08/12/2005 _~_-c_!flcaflons Test Data Strength 4000 psi @ 28 Days Placement Date 07/28/2005 Slump 3 in min 5 in max Sampled By Richard Jones Air Content 3 % min 6 % max Weather Partly Cloudy/Sunny/lite wind Concrete Temperature n/a Supplier/Mix TXI/517 Ambient Temperature n/a Air Content Method ASTM C231 Ticket Number: Slump: Concrete Temperature: Placement Location: Sample Location: 90083 Time Batched: 10:27 5 in Air Content: 6.0 % 90° F Ambient Temperature: 80° F Paving: East parking and fire lane From southern most southeast comer of slab, 50 feet south, 100 feet east Time Sampled: 11:20 Unit Weight: N/A Yardage (c.y.): 220/230 Concrete Compression Test Results Age Set # Cyl~.der Test Date (days) 03 DRO07280509 08~04~2005 7 03 DRO07280510 08/25/2005 28 03 DRO07280511 08/25/2005 28 03 DRO07280512 Hold Normal cylinder size: 6" x 12" Max Load Ama Stren!3th Fracture (lbs. force) (sq.in.) (ps~ Type 115940 28.27 4100 Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064; and C617 or C1231. O Gallons of Water Added On-Site CMJ Engineering, In R. Carl Lee, S.E.T. CMT Manager LIMITATIONS: The test results presented in this report apply only to the specific samples, items,~and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity. Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc, Page 3 of 3