Coppell Trade-LR051116,CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0158 Service Date: November 8, 2005 '1 rerracon 8901 Carpenter Frw,/, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: November 16, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:55am Plant: 141 Supplier: TXI Truck No: 921 Ticket No: 151473 Mix I.D. No.: 8206 Water Added Onsite Before Test: 0Cations Water Added Onsite After Test: 0 Gallons Sample Information Sample Time: 7:30am Date Cast: November 8, 2005 Technician: Eric G. Jernigan Weather Conditions: Partly cloudy and mild Accumulative Yards: 40 Placement Method: Direct Discharge Sample Locations: Dock #16 from south Placement Location: W side Fire Lane and Dock Parking, from middle of building to N end. Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.00 4.2 88 74 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 3 4 Specification Test Method 3-5 ASTM C143 3-7 ASTM C231 ASTM C1064 ASTM C1064 ASTM Cl 38 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 11/15/2005 7 104,280 3,690 11/15/2005 7 121,790 4,310 Average 4,000 12/06/2005 28 12/06/2005 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The testa were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0158 Service Date: November 8, 2005 refr lcon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: November 161 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 8:25am Plant: 141 Supplier: TXI Truck No: 805 Ticket No: 151631 Mix I.D. No.: 8206 Water Added Onsite Before Test: 10Gallons Water Added Onsite After Test: 0 Gallons Sample Information Sample Time: 9:00am Date Cast: November 8, 2005 Technician: Eric G. Jemigan Weather Conditions: Partly cloudy and mild Accumulative Yards: 140 Placement Method: Direct Discharge Sample Locations: Dock #22 Placement Location: W side Fire Lane and Dock Parking; From Dock #16-49 from south Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, O F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratorl/ Test Data set specimen Diameter No. ID (inches) 2 1 6.00 2 2 6.00 2 3 2 4 Result 4.50 3.9 85 76 Area (sq. inches) 28.27 28.27 Specification Test Method 3-5 ASTM C143 3-7 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 11/15/2005 7 107,120 3,790 11/15/2005 7 105,420 3,730 Average 3,760 12/06/2005 28 12/06/2005 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0158 Service Date: November 8, 2005 '}r rmcon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: November 16, 2005 Project: Coppell Trade Center- BIdg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 10:05am Plant: 141 Supplier: TXI Truck No: 805 Ticket No: 151807 Mix I.D. No.: 8206 Water Added Onsite Before Test: 0Gallons Water Added Onsite After Test: 0Gallons Sample Information Sample Time: 10:45am Date Cast: November 8, 2005 Technician: Eric G. Jernigan Weather Conditions:Partly cloudy and mild Accumulative Yards: 240 Placement Method: Direct Discharge Sample Locations: Transformer Pad Placement Location: W side Dock Parking, Transformer Pad and Dumpster Pad Field Test Data Test Result Slump, inches: 5.25 Air Content, %: 4.0 Concrete Temperature,° F: 84 Ambient Temperature, o F: 79 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. iD (inches) (sq. inches) 3 1 6.00 28.27 3 2 6.00 28.27 3 3 3 4 Specification Test Method 3-5 ASTM C143 3-7 ASTM C231 ASTM C1064 ASTM C1064 ASTM Cl 38 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 11/15/2005 7 101,970 3,610 11/15/2005 7 99,380 3,510 Average 3,560 12/06/2005 28 12/06/2005 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Eric G. Jernigan Report Distribution: (1) TechniStructures (1) ~Fadden & Miller Reviewed by: (1) City of Coppell TX (1) Macatee Engineering Inc Senior Pr~t M~er The tests were ~ormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repo~ is exclusively for the u~of the client indicated above and shall not ~ reproduced except in full without the wri~en consent of our core.ny. Test resuEs transmitted herein are only applicable to the actual samples tested at the I~ation(s) referenced and are not necessarily indicative of the pmpe~ies of other apparently similar or identical materials.