Loading...
Coppell Trade-LR051111· CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0133 Service Date: October 13, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Spdngs Rd Ste 300 Addison TX 75001 8901 Carpenter Fn,vy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Project: ~oppell Tr, aQe Center - ~ _ NWC- -S__a._n_d~ rt P k~y~,~ Coppel,, TX Project No.: 94051190 ~./~'~/ .7 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 8:00am Plant: 141 Supplier: TXI Truck No: 574 Ticket No: 136256 Mix I.D. No.: 8206 Water Added Onsite Before Test: 0Gallons Water Added Onsite After Test: 0Gallons Sample Information Sample Time: 8:30am Technician: Edc G. Jernigan Weather Conditions: Clear, cool and mild Accumulative Yards: 70 Placement Method: Direct Discharge Sample Locations: At 4 Date Cast: October 13, 2005 Placement Location: Pavement on W side of building adjacent to Lines 3 to 8 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 6.25 3.5 94 75 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Specification Test Method 3-5 ASTM C143 3-7 ASTM C231 ASTM C1064 ASTM C1064 ASTM Cl 38 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 10/20/2005 7 99,150 3,510 10/20/2005 7 103,160 3,650 Average 3,580 11/10/2005 28 131,890 4,660 11/10/2005 28 130,520 4,620 Average 4,640 Comments: Not tested for plastic unit weight. Tested Truck #64 twice. Too wet first test and also too wet for second test. 30 yard load Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indiceted above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicetive of the properties of other apparently similar or identical materials, Page 1 of 2 ~,~c~, ,CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0133 Service Date: October 13, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Spdngs Rd Ste 300 Addison TX 75001 "lrr=rracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: November 11, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 9:45am Supplier: TXI Truck No: 112 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Plant: 141 Ticket No: 136470 0 Gallons 0 Gallons Sample Information Sample Time: 10:20am Date Cast: October 13, 2005 Technician: Eric G. Jemigan Weather Conditions:Sunny, clear and mild Accumulative Yards: 170 Placement Method: Direct Discharge Sample Locations: At 6.5 on W side Placement Location: Pavement on SW side of building Lines 3-8 on W side Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 4.1 Concrete Tempereture,° F: 95 Ambient Temperature, o F: 83 Plastic Unit Weight, pcf: Laboratory Test Data set specimen Diameter Area No. ID (inches) (sq. inches) 2 1 6.00 28.27 2 2 6.00 28.27 2 3 6.00 28.27 2 4 6.00 28.27 Specification 3-5 3-7 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 10/20/2005 7 100,830 3,570 10/20/2005 7 97,490 3,450 Average 3,510 11/10/2005 28 127,650 4,510 11/10/2005 28 129,210 4,570 Average 4,540 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Eric G. Jemigan Report Distribution: (1) Coppell Trade Center LP (1) TechniStruct ures (1) City of Coppell TX (1) City of Coppell TX (1) Merriman Assoc Ina (1) McFadden & Miller (1) Macatee Engineering Inc Reviewed by: SRer~?;~pDr ;j eRc~y~Sa ~E~. e r~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusivery for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and ara not necessarily indicative of the properties of other apparently similar or identical materials.