Loading...
Denton Tap 1A-LR051117ECS - Texas, LLP 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 {FAX) 3924) 102 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL TO: Little Diversified Arch. Consulting 5001 Spring Valley Road, Suite 282-W Providence Towers Dallas, TX 75244 ATTN: Ms. Kathryn E. Rabuse JOB NO.: 004236A DATE: 11/1~ ;via - Coppell LOCATION: 131 N. Denton Tapp Road, Coppell, TX Dallas County County We are enclosing: X Attached X Materials Engineering Division Concrete Reports: 4 CC: Centex Construction Co. - Claud Bolton Centex Construction Co. - Robert Boe Wachovia Corporate Real Estate - Ken Clausen Little Diversified Arch. Consultants - Philip F. Ritchie City ofCoppell - Lee Stone City ofCoppell - Larry Davis Little Diversified Arch. Consulting - Jaime Nenclares By: Daniel Franklin, P.E. pre~~pal Engineer J~llen, SET Uonstruction Services Manager  4950 Keller Springs Road, Suite480 Addison, TX 75001 (972) 392-3222 Project: Wachovia - Coppell Location: 131 N. Denton Tapp Road, Coppell, TX Concrete Cylinders Strength Report Project: 4236-A Set Designation: A Cast Date: 10/20/2005 Design Strength: 3500 psi Report No.: 4 Oxvner: Wachovia Corporate Real Estate - Ken Client: Little Diversified Arch. Consultants - Arch.: Little Diversified Arch. Consulting - Jaime Gen. Contr.: Centex Construction Co. - Struc. Eng.: Cone. Contr.: Placement Location: Piers at locations: A/3, A/5, B/3, and J/7. Sampled at pier A/3. Concrete Supplier: Southern Star Truck No: 31 Ticket No: 1013015 Mix Designation: 9341 Mix Strength:3500 psi Batch Time: 08:45AM Added Water: Time Added: Unit Wt.: FIELD TEST DATA: Tested by:Louis J. DeRossi Time Sampled:09:25AM Slump:4.75 in. Temperature - Air: 74° F Concrete: 79° F Air Content:0.80 % (p) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load, lbs Str.,psi Typ by by 23484 10/27/2005 7 Lab 6.00 28.27 92288 3260 4 JBA1 23485 11/17/2005 28 Lab 6.00 28.27 132224 4680 3 JBA1 23486 11/17/2005 28 Lab 6.00 28.27 138688 4910 3 JBA1 23487 12/15/2005 56 Lab 6.00 28.27 Cylinder molding and laboratoq curing law ASTM C31, compressive strength test and break type law ASTM C39, slump law C143, air content law ASTM C173 (V) or C231 (P), temperatureiawASTMClO64, andunitweightiawASTMC138 Cylindersaretestedusing unbondedcapsiawASTMC1231 orarecapped using sulphur mortar iaw C6t7, Break Types are classified as: Type 1,2, 3, 4, 5, or 6 law C39-04a FIELD CURING CONDITIONS: Curing Box Insulated Cooled Ice X No Curing Box Heated X Caps Other Remarks: Final Review By: JBA 1 Print Date: 11/17/2005