Loading...
Denton Tap 1A-LR051114(972) 392-3222 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL TO: Little Diversified Arch. Consulting 5001 Spring Valley Road, Suite 282-W Providence Towers Dallas, TX 75244 ATTN: Ms. Kathryn E. Rabuse PERMIT #: 004236A ION: 131 N. Denton Tapp Road, Coppell, TX Dallas County County We are enclosing: X Attached X For Your Use X Materials Engineering Division Concrete Reports: X As Requested 1 CC: Centex Construction Co. - Claud Centex Construction Co. - Robert s -- - ion Services Manager By: Daniel Franklin, P.E. President/Principal Engineer  4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 '-:---:~rZ~l (FAX) 392-0102 Project: Wachovia - Coppell Location: 131 N. Denton Tapp Road, Coppell, TX Concrete Cylinders Strength Report Project: 4236-A Set Designation: A Cast Date: 10/17/2005 Design Strength: 3500 psi Report No.: I Owner: Wachovia Corporate Real Estate - Ken Client: Little Diversified Arch. Consultants ~ Arch.: Little Diversified Arch. Consultants - Philip Gen. Contr.: Centex Construction Co. - Struc. Eng.: Cone. Contr.: Placement Location: Piers at locations C/l, D/l, E.1/1.5, E.5/2, J/10, J/8, D/2, C/9, C/10, D/10. Sampled at Pier D/1. Concrete Supplier: Southern Star Truck No: 6019 Ticket No: 959543 Mix Designation: 9337 Mix Strength: 3500 psi Batch Time: 11:20AM Added Water: Time Added: Unit Wt.: FIELD TEST DATA: Tested by:Louis J. DeRossi Time Sampled:12:00PM Slump:5.50 in. Temperature - Air: 80° F Concrete: 83° F Air Content:0.80 % (p) Sample Test Test Type Otemet~r Area Breaking Compr. Brk Break Review No Date Age Cure In. In.: Load,lbs Str.,psi Typ by by 23416 10/24/2005 7 Lab 6.00 28.27 86592 3060 3 JBA1 23417 11/14/2005 28 Lab 6.00 28.27 134688 4760 JBA1 23418 11/14/2005 28 Lab 6.00 28.27 127744 4520 YBA1 23419 12/12/2005 56 Lab 6.00 28.27 ~ampling in accordance with (Jaw) ASTM Cl 72, except that samples may have been taken from the beginning of the load alt~ · a minimum discha'ge of apprex~mateW ene cubic yard. Cylinder m~ding and laboratmy curi.g iaw ASTM C31, compreSmVe ~e~gth test end break ~/pe iaw ASTM C39, slurr~o iaw C143, air content iaw ASTM C173 (V) or C231 (P), ternpera[ure iaw ASTM C1064, and un~ weight iaw ASTM C138. Cyli~de~ are testhd using unbended caps iaw ASTM C1231 or are capped using sulphur mortar law C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 law C39-04a FIELD CURING CONDITIONS: Curing Box Insulated Cooled Ice X No Curing Box Heated X Caps Other Remarks: Final Review By: -- JBA 1 Print Date: 11/14/2005