Loading...
Fairways-CS 880628 AGENDA City of Coppell DEVELOPMENT REVIEW COMMITTEE June Z8, 1988 The regularly scheduled meeting of the City of Coppell Development Review Committee will be held on Tuesday, June ZS, 1988, at 8:30 a.m., in the first floor Conference Room of the Town Center, Z55 Parkway Boulevard. An Engineer for the project or other representative is urged to attend this meeting; however, attendance is not mandatory. .'.,~"~ZC-509 .)East of Denton Tap Road, and north of Bethel Road; ZC-514 Northeast corner of Mockingbird Lane, and the St. Louis and Southwestern Railroad. Zoning Change (SF-1Z) Single Family-lZ to (R) Retail Fairways at Riverchase - Preliminary Plat CITY OF COPPELL ENGINEERING DEPARTMENT DRC DATE: REVIEW OF: BY: Shohre Daneshmand, Civil Engineer PRELIMINARY PLAT AND PLANS: A. Please make the following additions and/or corrections, as marked: 1) 2) 3) The names and zoning of adjacent properties, names on r~cord of owners of adjoining parcels. The location, widths and names of all existing and proposed streets, easements, fire lanes or other public ways within or adjacent to the tract. Existing and proposed zoning of the site and the surrounding properties. Topography of the site (intervals of 5 feet or less,referred tn sea level datum). Per Floodplain Management Ordinance, (Art. 5, Sec. C, Item 4, Page 34), all subdivision proposals must have the following note placed on the preliminary and final plats: "Floodplain Development Permit Application No. has been filed with the City of Coppell Administrator on , 19 Floodplain (Floodplain Administrator) (Date) The following information, as marked, is required to be contained in the preliminary engineerin~ plans. Submit preliminary engineering plans. The plans shall show existing structures utilities . . sewers . water mains . . culverts and other underground structures within the tract immediately adjacent thereto with pipe sizes and locations. 3) Preliminary plans of proposed water dietrfbution system . . sewage collection system , and their relation to the existing utilities in the area, and to the ~tility Master Plan. Provide a Drainage Area Map, covering two parts: a) show On-site Drainage Map, on a scale of 1" ~ 20', 40', 50', etc .; with all details as required in the Subdivision Ordinance; b) show the Off-site Drainage Map, on a scale of 1" ~ i00', 200', etc . Delineate the project's boundary on it, plus the less detailed drainage system, to clearly demonstrate the affect of such activities, drainage outfalls, on the adjacent properties and the Drainage Master Plan. If the applicant is requesting any variance to the Subdivision Ordinance, he must submit a letter specifically outlining his respective requests. Show the boundaries of the 100-year Floodplain and Floodway clearly on the preliminary and final plats. 8) / Ail above comments must be addressed, prior to Engineering Staff's final recommendation on this plat. DRC/COMMENTS/ENG/PRELIM MEMO1 3) Preliminary plans of proposed water distribution system . . sewage collection system . · , and their relation to the existing utilities in the area, and to the Utility Haster Plan. Provide a Drainage Area Map. covering two parts: a) show On-site Drainage Map, on a scale of 1" - 20', 40', 50', etc Subdivisio~ .; with all details as required in the Ordinance; b) show the Off-site Drainage Map, on a scale of l" - 100', 200', etc. . Delineate the project's boundary on it, plus the less detailed drainage system, to clearly demonstrate the affect of such activities, drainage outfalls, on the adjacent properties and the Drainage Master Plan. All above comments must be addressed, prior Staff's final recommendation on this plat. If the applicant is requesting any variance to the Subdivision Ordinance, he must submit a letter specifically outlining his respective requests. Show the boundaries of the lO0-year Floodplain and Floodway clearly on the preliminary and final plats. to Engineering DRC/COM~!ENTS/ENG/PRELIM MEMO1