Northlake WE P10B-CS 851031GINN, INC. October 31, 1985 CONSULTING ENGINEERS Don. A. Tipton, Inc. 6330 Belt Line Road, Suite C Garland, TX 75043 Re: Northlake woodlands East - Phase 10 Final Plat Gentlemen: We have reviewed the above referenced project for conformance to the City of Coppell Zoning Ordinance and Subdivision Ordinance. Prior to placing on any agenda for approval, the following items need to be addressed. 1. Street centerline alignment of Crane Circle and Crane Drive, either side of Mockingbird Lane, is less than 125 feet. This is in conflict with the Subdivision Ordinance. Please address. A similar conflict Occurs with the centerline inter- sections of Brant Circle and Mallard Drive. 2. The pavement shown on the plans, for the alleys, are not in conformance with the City of Coppell standards. Please address. 3. At Bethel School Road and Mockingbird Lane, the radius should be 25', not 20' as shown. 4. A screening wall, in accordance with Zoning Ordinance Section 32.1.7, shall be provided along MacArthur Boulevard. 5. Maximum allowable grade is 5%. Alleys No. 10 and NO. 11 have an 8% grade. Please address. 6. For I = 7.8 in/hr., Tc = 15 min., this reflects a 25 year storm frequency based on TP-40; not a 100-year design frequency as required by City of Coppell. For 100-year design frequency and Tc = 15 min., I = 9.8 in/hr. Minimum time of concentration should be 10 minutes, unless justi- fied otherwise. In that case, I = 11.6 in/hr. Please address. Line "C" of storm drainage system, please provide cross section of "grade to drain" ditch. On Line "E" of storm sewer, with all the horizontal curves, vertical breaks and pipe change sizes, is there any possi- ble way this could be revised to provide for more "fluid" design without interfering with other utilities? 16135 Preston Road · SuiTe 106 · Dallas, Texas 75248 · Phone 214/386-6611 Maximum spacing on sanitary sewer manholes shall be 500 feet. On Falcon Lane, Line "C-l" add a manhole as shown on plans. Additional manholes as shown on plans shall be provided. Provide manholes in lieu of cleanouts at ends of lines greater than 200 feet from a manhole. 10. Minimum size sanitary sewer main shall be 8" diameter. No 6" will be allowed by Subdivision Ordinance. 11. No horizontal curves in sanitary sewer are permitted. This was addressed in our preliminary review comments. 12. Minimum water main size shall be 8" diameter, in accor- dance with Subdivision Ordinance. 13. Sanitary sewer mains to be PVC, SDR 35. 14. Water mains to be PVC, Class 200, DR 14. 15. No jetting of backfill shall be allowed. 16. Embedment of backfill shall be as per minimum City standards or better. 17. Maximum velocities or sanitary sewer lines is 10 f.p.s. We will not recommend placing this on any agenda for approval until the above items are addressed. If you feel we need to discuss these items, please do not hesitate to contact us. Sincerely, Gabe Favre /sr cc: Vivyon Bowman Steve Goram