Denton Tap 1A-LR051128ECS - Texas~ LLP
4950 Keller Springs Road,Suite 480
Addison, TX 75001
(972) 392-3222
(FAX) 392-0102
November 28, 2005
Little Diversified Arch. Consulting
5001 Spring Valley Road, Suite 282-W
Providence Towers
Dallas, TX 75244
ATTN: Ms. Kathryn E. Rabuse
LETTER OF TRANSMITTAL
RE: Wachovia - Coppell
ECS Job # 19:4236-A
Permits:
Location: 131 N. Denton Tapp Road
Coppell, TX
We are enclosing: X Materials Engineering Division Reports
For your use
X As requested
CC: Centex Construction Co. - Claud Bolton
Centex Construction Co. - Robert Boe
Wachovia Corporate Real Estate - Ken Clausen
Little Diversified Arch. Consultants - Philip F. Ritchie
City of Coppell - Lee Stone
CityofCoppell- Larry Davis
Little Diversified Arch. Consulting - Jaime Nenclares
ENCL:
Field Report # 21 11/22/2005
Daniel Franklin, P.E.
President/Principal Engineer
J_~a~9~lle-n, ~ ET
~':construction Services Manager
ECS - Texas~ LLP
4950 Keller Springs Road, Suite 480
Addison, TX 75001
(972) 392~222
(FAX) 392-0102
Project Wachovia - Coppell
I. ocatio~ Coppell, TX
Client Little Diversified Arch. Consulting - Kathryn E. Rabuse
Contractor Centex Construction Co. - Claud BoRon
Remarks
Trip Charges*
Chargeable Items
Tolls/Parking* Mileage* 40
FIELD REPORT
Project No. 19:4236-A
Repor~ No. 21
Day & Date Tuesday 11/22/2005
Weather 58°/Sunny
On-Site Time 1.00
Lab Time 0.25
Travel Time* 1,00
Total 2.25
Re Obs,Tlme 0.00
Time of Arrival Departure
08:00A 09:00A
* Travel time and mileage will ~ billed in accordance with the contract,
Summery of Ser¥tces performed (field test data, Iocalons, elevafions & depths are estimates) & Individuals Contacted.
Concrete Cylinder Pick-up:
The undersigned arrived on site to retrieve concrete cylinders molded on a previous date.
The test cylinders were found to be undisturbed and were returned to ECS for curing and
compressive strength testing.
4 sets of 4 cylinders were picked up on this date.
By Louis DeRossi
1700
71228
4950 Keller Springs Road, Suite 480
Addison, TX 75001
(972) 392-3222
(FAX) 392-0102
CONCRETE, GROUT, AND MORTAR TESTS
LETTER OF TRANSMITTAL
TO: Little Diversified Arch. Consulting
5001 Spring Valley Road, Suite 282-W
Providence Towers
Dallas, TX 75244
ATTN: Ms. Kathryn E. Rabuse
JOB NO.: 004236A
DATE: 11/28/2005
RE: Wachovia - Coppell
PERIvIIT #:
LOCATION:
131 N. Denton Tapp Road, Coppell, TX
Dallas County County
We are enclosing:
X Attached
X Materials Engineering Division Concrete Reports:
9, 10, 11, 12
X For Your Use
X As Requested
CC: Centex Construction Co. - Claud Bolton
Centex Construction Co. - Robert Boe
Wachovia Corporate Real Estate - Ken Clausen
Little Diversified Arch. Consultants - Philip F. Ritchie
City ofCoppell - Lee Stone
City ofCoppell - Larry Davis
Little Diversified Arch. Consulting - Jaime Nenclares
J_aso~l~efi, SET r .
Gffnstruction Services Manager
By: Daniel Franklin, P.E.
President/Principal Engineer
4950 Kelle~ Springs Road, Suite 480
Addison, TX 75001
(972) 392-3222
(FAX) 3924)102
Project: Wachovia - Coppell
Location: 131 N. Denton Tapp Road, Coppell, TX
Concrete Cylinders Strength Report
Project: 4236-A Set Designation: A
Cast Date: 11/2t/2005
Design Strength: 3500 psi
Report No.: 9
Owner: Wachovia Corporate Real Estate - Ken Client: Little Diversified Arch. Consultants -
Arch.: Little Diversified Arch. Consulting - Jaime Gen. Contr.: Centex Construction Co. -
Struc. Eng.: Conc. Contr.:
Placement Location: Paving, sample location 20'E/10qN of NE building comer.
Concrete Supplier: Southern Star Truck No: 8 Ticket No: 1053946
Mix Designation: 9339 Mix Strength: 3500 psi Batch Time: 03:40AM
Added Water: Time Added: Unit Wt.:
FIELD TEST DATA: Tested by:Louis J. DeRossi Time Sampled:04:15AM Slump: 5.00 in.
Temperature - Air: 38° F Concrete: 65° F Air Content:5.00 % (p)
Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review
No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by
23984 11/28/2005 7 Lab 6.00 28.27 95520 3380 3 JBA1
23985 12/19/2005 28 Lab 6.00 28.27
23986 12/19/2005 28 Lab 6.00 28.27
23987 01/16/2006 56 Lab 6.00 28.27
;amolin~ in accordance with (law) ASTM C172, except that samples may have bees taken from the beginning of the load alter a minimum discharge of approximately one ~bic yard,
flinder molding and laboratory curing law ASTM C31, compressive strength test and break type law ASTM C39, slump law C143, air content law ASTM C173 (V) or C231 (P),
temperature law ASTM C1064, and unit weight law ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur
mortar law C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 law C39-04a
FIELD CURING CONDITIONS:
Curing Box Insulated Cooled Ice
X No Curing Box Heated X Caps Other
Remarks:
Final Review By:
JBA 1
Print Date: 11/28/2005
4950 Keller Springs Road, Suite 480
Addison,TX 75001
(972) 392-3222
(FAX) 3924102
Project: Wachovia - Coppell
Location: 131 N. Denton Tapp Road, Coppell, TX
Concrete Cylinders Strength Report
Project: 4236-A Set Designation: B
Cast Date: 11/21/2005
Design Strength: 3500 psi
Report No.: 10
Owner: Wachovia Corporate Real Estate - Ken Client: Little Diversified Arch. Consultants -
Arch.: Little Diversified Arch. Consulting - Jaime Gen. Contr.: Centex Construction Co. -
Struc. Eng.: Conc. Contr.:
Placement Location: Paving, sample location 30'N/50'W of NE building comer.
Concrete Supplier: Southern Star Truck No: 1015 Ticket No: 1053957
Mix Designation: 9339 Mix Strength: 3500 psi Batch Time: 05:17AM
Added Water: Time Added: Unit Wt.:
FIELD TEST DATA: Tested by:Louis J. DeRossi Time Sampled:05:40AM Slump:5.25 in.
Temperature - Air: 35° F Concrete: i4° F Air Content:5.50 % (p)
Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review
No Date Age Cure In. In.2 Load, lbs Str.,psi Typ by by
23988 11/28/2005 7 Lab 6.00 28.27 102272 3620 5 JBA1
23989 12/19/2005 28 Lab 6.00 28.27
23990 12/19/2005 28 Lab 6.00 28.27
23991 01/16/2006 56 Lab 6.00 28.27
Cylinder reading and laboratory curing law ASTM C31, compressive strength test and break t,/pe iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P),
temperalure law ASTM C1064, and unit weight law ASTM C138. Cylinders are tested using unbonded caps law ASTM C1231 or are capped using sulphur
mortar iaw C61L Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39-04a
FIELD CURING CONDITIONS:
Curing Box Insulated Cooled Ice
X No Curing Box Heated X Caps Other
Remarks:
Final Review By:
JBAI
Print Date: 11/28/2005
4950 Keller Springs Ro~d, Suite 480
Addison. TX 75001
(972) 392-3222
(FAX) 3924)102
Project: Wachovia - Coppell
Location: 131 N. Denton Tapp Road, Coppell, TX
Concrete Cylinders Strength Report
Project: 4236-A Set Designation: C
Cast Date: 11/21/2005
Design Strength: 3600 psi
Report No.: 11
Owner: Wachovia Corporate Real Estate - Ken Client: Little Diversified Arch. Consultants -
Arch.: Little Diversified Arch. Consulting - Jaime Gen. Contr.: Centex Construction Co. -
Struc. Eng.: Cone. Contr.:
Placement Location: Paving, sample location 20'W/30'S of NW building comer.
Concrete Supplier: Southern Star Truck No: 278 Ticket No: 1053908
Mix Designation: 7752 Mix Strength: 3600 psi Batch Time: 08:35AM
Added Water: Time Added: Unit Wt.:
FIELD TEST DATA: Tested by:Louis J. DeRossi Time Sampled:09:00AM Slump: 6.75 in.
Temperature - Air: 44° F Concrete: 680 F Air Content:4.00 % (p)
Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review
No Date Age Cure In. In? Load,lbs Str.,psi Typ by by
23992 11/28/2005 7 Lab 6.00 28.27 98880 3500 4 JBAI
23993 12/19/2005 28 Lab 6.00 28.27
23994 12/19/2005 28 Lab 6.00 28.27
23995 01/16/2006 56 Lab 6.00 28.27
Sampling in accordance wilh (law) ASTM C172, except that samples may have bee~ {aken from the beginning of the load after a minimum discbarge of approximately one cubic yard.
Cylinder molding and labora~ry cudng law ASTM C31, compressive strength test and break [ype law ASTM C39, slump law C143, air content law ASTM Cl 73 (V) or C23'~ (P),
temperalure law ASTM C1064, and unit weight law ASTM C138. Cylinders are tested using unbonded caps law ASTM C1231 or are capped using sulphur
mortar iaw C617. Break Types are classified as: Type 1, 2, 3~ 4, 5, or 6 law C39-04a
FIELD CURING CONDITIONS:
Curing Box Insulated Cooled Ice
X No Curing Box Heated X Caps Other
Remarks:
Final Review By:
JBA 1
Print Date: 11/28/2005
ECS - Texas, LLP
4950 Keller Springs Ro~d, Suite 480
Addison, TX 75001
(972) 392-3222
(FAX) 3924)102
Project: Wachovia - Coppell
Location: 131 N. Denton Tapp Road, Coppell, TX
Concrete Cylinders Strength Report
Project: 4236-A Set Designation: D
Cast Date: 11/21/2005
Design Strength: 3600 psi
Report No.: 12
Owner: Wachovia Corporate Real Estate - Ken Client: Little Diversified Arch. Consultants -
Arch.: Little Diversified Amh. Consulting - Jaime Gen. Contr.: Centex Construction Co. -
Struc. Eng.: Conc. Contr.:
Placement Location: Paving, sample location at the approach of pavement, perpendicular to side street.
Concrete Supplier: Southern Star Truck No: 2 Ticket No: 958427
Mix Designation: 7752 Mix Strength: 3600 psi Batch Time: 10:05AM
Added Water: 10 Gals. Time Added: 11:00A Unit Wt.:
FIELD TEST DATA: Tested by:Louis J. DeRossi Time Sampled:l I:15AM Slump:5.50 in.
Temperature - Air: 59° F Concrete: 4° F Air Content:4.50 % (p)
Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review
No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by
23996 11/28/2005 7 Lab 6.00 28.27 82304 2910 2 JBAI
23997 12/19/2005 28 Lab 6.00 28.27
23998 12/19/2005 28 Lab 6.00 28.27
23999 01/16/2006 56 Lab 6.00 28.27
Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately sse cubic yard.
Cylinder molding and laborat~y cudng law ASTM C31, compressive sb'ength test and break type law ASTM C39, slump iaw Cl 43, air content iaw ASTM C173 (V) or C231 (P),
temperature iaw ASTM C1064, and unit weight iaw ASTM Cl 38. Cylinders ere tested using unbonded caps iaw ASTM C1231 or are capped using sulphur
mortar iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39q)4a
FIELD CURING CONDITIONS:
Curing Box Insulated Cooled Ice
X No CuringBox Heated X Caps Other
Remarks:
Final Review By:
JBA1
Print Date: 11/28/2005
ECS - Texas~ LLP
4950 Keller Sprin~ Road, Sulle 480
Addison, TX 75001
(972) 392.3222
{FAX) 392-0102
Project Wachovia - Coppell
Location Coppell, TX
Client Little Diversified Arch. Consulting - Kathryn E. Rabuse
Contractor Centex Construction Co. - Claud Bolton
Remarks
Tdp Charges*
Chargeable Items
Tolls/Parking* Mileage* 40
FIELD REPORT
Project No. 19:4236-A
Report No. 22
Day & Date Monday 11/28/2005
WeaNer 60°/Sunny
On-Site Time 4.00
Lab Ti me 0.25
Travel Time* 1.00
Total 5.25
Re Obs.'I~me 0.00
Time of Arrival Departure
12:30P 04:30P
* Travel time and mileage will be billed in accordance with thc contract.
Summary ofSer~ces Perlormed (field test date, Iocalons, elevations & depths are estimates) & Individuals Contacted.
Concrete Placement Observation:
The undersigned arrived on site, as requested, to observe the placement of 10 cubic yards of
3500 psi concrete for light pole bases.
Prior to the placement of concrete, reinforcing steel was observed and appeared to be placed in
accordance with project drawings and specifications consisting of four #8 vertical bars, and #3
horizontal bars 16" OC,
Concrete observed on this date appeared to be placed in compliance with project specifications
with regard to temperature, slump, air content, and batch to placement time.
1 set of 4 cylinders was cast for compressive strength testing in our laboratory.
By John Zimont, -- Field Technician