Park West CC(1)-CS 900601GINN, INC. CONSULTING ENGINEERS Date: To: PL~T/PL~N REVIEW ~~ June 1, 1990 ~, Steve Goram, Director of Public ks City of Coppell From: Jo~uhe.r,R~E. Re:~Park West Commerce Center We have performed an initial review of these plans Public Works Department Section Heads and have the comments: with the following FINAL PLAT: Sheet 1: Owner's Certificate appears to be in error. Correct and clarify as noted on drawing. Variance omitting sidewalks was not approved - remove note from Final Plat. Show existing official limits of floodplain on Grapevine Creek. 4. Include the address of the Owner on the plat. Sheet 2: 5. Show all required easements on the plat. 6. Show dimensions on Grapevine Creek Channel. R.O.W. line curve calculations along south side of Southwestern Drive are in conflict with each other. 8. Show R.O.W. width of Belt Line Road. 9. Correct property corner detail Sheet 2. 10. Show R.O.W. width of Wrangler Drive. 17103 Preston Road · Suite 100 · LB 118 · Dallas, Texas 75248 · Phone 214/248-4900 Sheet 3: 11. Correct R.O.W. dimensions as marked. 12. Correct Utility Easement as marked. Sheet 4: 13. 14. 15. 16. Show existing and dedicated R.O.W. on Southwestern Drive. Show correct dimensions along channel in areas marked drawings. Identify easements as marked on drawing. Sheet 5 - Correct dimensions and details as indicated. on Sheet 6: 17. Show Belt Line Road R.O.W. 18. Correct dimensions as shown. 19. Identify easement type and size east side of Block 7. UTILITY PLANS: 1. Sheet 7 - Utility Key - Show existing and proposed utilities and Sheet 8: 2. identify by size, type, line no., etc. Sheet 9: 7. Se Upgrade existing 8" waterline in Belt Line Road to 12" and connect to 24" waterline (existing). Minimum 20' utility easements - revise as indicated. Where is detail for tie in of 8" waterline to 24" waterline between Executive Drive and Belt Line? Enlarged drawings referred to for 8" and 24" waterline not included. Include with re-submittal. Same as #5 above for utilities in Southwestern at Belt Line. Clarify status of sewer line and laterals shown in Freeport Pkwy. Revise Legend to show proposed and existing fire hydrants. Profile all waterlines. 10. Show existing 12" waterline in Southwestern Drive and show tie-in to proposed 12" in "new" Southwestern Drive. 11. Show tie-in to existing 8" waterline as marked on plans. Sheet 10: 12. Easement widths do not match those on Final Plat - Clarify and revise accordingly. 13. Show 50' Lone Star Gas Easement at Wrangler Drive. 14. Label existing waterline on north side of Wrangler Drive to be abandoned. 15. Label proposed 12" waterline on south side of Wrangler Drive and show existing 12" waterline and where proposed is to be connected. 16. Revise Legend to show proposed and existing fire hydrants and valves. Sheet 11: 17. Easement widths do not match those on Final Plat. and revise accordingly. Clarify 18. Explain the difference between bold and fine lines used to indicate valves and fire hydrants. Revise sheet accordingly. 19. Revise Legend to show proposed and existing fire hydrants and valves. 20. Show existing 12" waterline at Belt Line Road. 21. Identify upgrade of 8" to 12" waterline at Belt Line Road. Sheet 12: 22. Identify the revisions to the Belt Line/Airline intersection (ie. relocation of 12" waterline and valves). 23. Profile all sanitary sewer lines. 24. Show detail of proposed 8" stubout and manhole in Bullock Drive to tract east of Bullock Drive and north of proposed Southwestern Drive. 25. Show proposed upgrade of 12" sanitary sewer line to 24". 26. Revise to show existing 12" sanitary sewer instead of 8" as indicated on plans. 27. Show enlarged plans for utilities in Southwestern and Belt Line Road and of Southwestern Drive as called for on plan. 28. Show detail of manhole and stubout where railroad intersects Executive Drive. 29. Clarify and revise to distinguish between the railroad centerline and a proposed utility. Sheet 13: 30. Profile all sanitary sewer lines. 31. Show existing sanitary sewer along east side of Freeport Parkway from proposed Southwestern Annex as indicated on plan. 32. Revise to show existing 12" sanitary sewer along Coppell Road instead of 8". 33. Show enlarged plans for water and sanitary sewer systems in Southwestern Drive. 34. Portions of sanitary sewer around the Southwestern Drive/Southwestern Annex intersection and the Southwestern Drive/Coppell Road intersection are shown as existing but they are not. Clarify what is existing and what needs to be proposed. 35. Show existing sanitary sewer along Southwestern Drive. Sheet 14: 36. Profile all sanitary sewer lines. 37. Easement widths do not match those on Final Plat. Clarify and revise accordingly. 38. Show all existing and proposed easements. 39. Provide sanitary sewer for area of Wrangler Drive indicated on plan. Sheet 15: 40. Profile all sanitary sewer lines. 41. Easement widths do not match those on Final Plat. and revise accordingly. Clarify 42. Show existing sanitary sewer in Crestside Drive and for old High School. 43. Show existing water and sewer easements'in Block 7 as shown on plan. 44. Upgrade 10" sanitary sewer to 12" along Airline Drive from International Drive to Belt Line Road. 45. Upgrade 12" sanitary sewer to 24" along Belt Line Road from Airline Drive to Southwestern Drive. PAVING PLANS: 1. Paving and Drainage Plans and Profiles are needed for Southwestern Drive. Sheet 17: Ail grades are to be checked and corrected accordingly, typical for all paving sheets. Wrangler Drive is to be improved and shown as such for plans of streets intersecting Wrangler Drive. 4. Ail corner radii are to be 40' to accommodate truck traffic. Sheet 19 - Street grades are to be indicated on profile from sheet to sheet even if there is not a grade change. Sheet 20: Show existing drainage ditch on north side of Wrangler Drive and indicate where it is draining. Show street grades on profile. Include vertical curve in areas with a change in grade of 1% or more. 8. Sheet 22 - Show street grades in profiles. Sheet 23 - Show street grades and vertical curves in profile, 10. Sheet 23 - Show existing drainage ditch and indicate where it drains. 11. Sheet 26 - Only a minimum street grade of 0.50% will be allowed. 12. Sheet 27 - Show street grades in profile. 13. Sheet 28 - Show street grades in profile using a minimum grade of 0.50%. 14. Sheets 29-36 - Wrangler Drive is to be designed and constructed as part of this project. 15. Sheets 32-34 - Corner radii at intersecting streets south of Wrangler to be a minimum of 30'. 16. Sheets 34-36 - Minimum street grade shall be 0.50%. DRAINAGE PLANS: 1. Sheet 37 Drainage area map does not match Final Plat. Clarify and revise accordingly. 2. Sheets 38-40 - Rainfall intensity shall be determined using U.S. Department of Commerce Weather Bureau Technical Paper No. 40. e Sheets 41-59 - Include lateral profiles on all sheets. Show hydraulic grade line for the entire system and make sure all existing and proposed grade lines and proposed flow lines match from sheet to sheet. 4e Sheets 41-59 - A minimum of 2 feet of clearance shall be required between bottom of concrete pavement and top of pipe and culverts. Se e Sheets 44-49 - Removal of the existing pavement along Wrangler Drive to facilitate the installation of drainage culverts will require replacement according to City of Coppell Standards. Furnish letter of Map Revision or Conditional Letter of Map Revision verifying FEMA's acceptance of Grapevine Creek Channel modifications. Sheet 51: 6. Where are plans for drainage along Southwestern Drive? 10. Provide plans for the rest of Line D. Show location of existing 24" waterline in profile. There is a drainage culvert shown just east of Executive Drive under Southwestern Drive but it is not labeled. Is this existing? To be abandoned? If proposed, where are plans? Sheet 52 - Clarify location of Line E and provide plans for the remainder of Line E. 11. 12. Sheet 54 - Make a greater distinction between the existing and the proposed storm drainage culverts. Sheet 56 - Need rip rap detail. Not shown in plans. 13. Sheet 59 - Show what is existing and what part of storm drain is proposed in profile. CC: Gary Sieb Donald E. Davis Consulting Engineers File 90441