Loading...
Parks Coppell-CS 930729 PUBLIC WORKS Mi~IORANDUM DATE: TO: FROM: RE: luly 29, 1993 Larry Davis, Construction Inspector Howard L. Pafford, Utilities Superintenden[~ Walkthrough of Parks of Coppell Field personnel conducted a follow-up walk through of the above referenced project and the following items remain deficient: Lot 1 Line E on Chestnut Lane - Repour pad. Raise clean out to accommodate lid. The chimney seal at Chestnut Court and Chestnut Lane is loose at the bottom. Lot 11 Block B - Sewer lateral is too deep. Lot 21 Block B - The chimney seal is loose at the bottom - Neck on Manhole not allowing seal to seal. Lot 4 Block C - Chimney Seal loose at the bottom. Lot 6 Block C - Unable to locate the clean out. /9~ 7. Lot 3 Block E - Bottom of Lateral Y to clean out busted from being run over. One mainline valve extension to the south not on nut. The screening wall contractor will have to set final grade in the right-of--way and sidewalk will have to be completed along Parkway Blvd. Additionally, it may be necessary to inform the contractor that adapters can be purchased to help properly install the chimney seals mentioned above. Please have the contractor contact staff when all items have been corrected. This project should not be accepted until all punch list items are corrected. /dm WALKTHRU.HLP/PARKSCOP COPPELL PUBLIC WORKS MEMORANDUM DATE: July 21, 1993 TO: ~arry Davis, Construction Inspector FROM: Howard L. Pafford, Utilities Superintendent Walkthrough of Parks of Coppell Field personnel perforn~d a walk through at the above referenced subdivision this morning. The following items were found to be deficient: 1~) lC-Grout around inside of ring in the existing manhole at Chesmut Lane and Heartz. Need a clean out at Lot 1 Line E on Chestnut Lanez.~o,,ff, The chimney seal at Chestnut Court and Chestnut Lane is loose at the bottom. Lot 11 Block B - Sewer lateral is too deep. 5.~/~2" blow off at end of Kallew Way needs a 24" x 24" meter can. Lot 21 Block B - The chimney seal is loose at the bottom. t~/K~6A. LOt 21 Block B - Clean out needs straightened. LOt 4 Block C- Clean ~n~ete out bottom of inve~. ~' ~'~,,,,,.,,.e~ LOt 6 Block C- Unable ~)~a~_~.~e clean out.. 10~'~Lot 15 Block D - Unable to locate manhole. 11E>L'(Lot 5 Block E - Replace meter can. 12.[~-.Lots 1, 2, 3 Block E - Wrong type of meter installed. 13~-.Lot 1 Block E - The mainline valve for Sleepy Hollow Lane needs valve extensions. At Flagstone Lan.9 and bridge entrance- Need two mainline valve extensions. WALKTHRU.HLP/PARKCOPP