Sandy L Add FL-CS 910222CHANGE REQUEST gl
FEBRUARY 22, 1991
FOOD LION STORE
SITE #6A, PROJECT #90-115
COPPELL, TEXAS
7
ARTECH DESIGN GROUP, INC.
The following revisions are hereby issued. If accepted, these revisions
shall void, supersede and take precedence over previously issued
drawings, specifications and addenda of same name and number and shall
become a part of the contract.
Sheet A-2 (Drawings not reissued - see notes below)
1. Delete double 2 x 6 wood cart stop at front of sales. (a)
2. Equipment Room Plan "1" - delete door #34 and ladder in Equipment
Room. (d)
Sheet A-3 (Drawings not reissued - see supplementary drawings below)
SUP. A-3.1 - Revised downspouts. (a)
Sheet A-5 (Drawings not reissued - see notes below)
1. Section "I" - top of masonry at rear of Receiving Room revised form
10'-8" to 11'-1" a.f.f. (d)
Sheet A-7 (Drawings not reissued - see supplementary drawings below)
SUP. A-7.1- Interior Elevation "B" and "C" - BM 13-12 Beige revised to
SW 1654 Lemon Wash. (d)
Sheet A-9 (Drawings not reissued - see notes below)
I. See note #6 for Meat Prep ceiling information. (d)
2. Detail "A" - Revised from gypsum board to plywood.
3. All gypsum board ceilings revised to 1/2" plywood painted.
Chg. Req. #1
Page 1 of~
.Sheet A-10 (Drawings not reissued - see notes below)
Room Finish Schedule -
1. Room 108 - Meat Storage - revise jamb color to white epoxy. (a)
2. Gypsum Board ceiling revised to plywood painted. (Rooms 103, 108,
109, 129 and 132)
Sheet A-11 (Drawin~ not reissued - see suvnlementary drawin~ below)
SUP. A-Il,l- Revised head detail "A". (a)
SUP. A- 11.3-
SUP, A-11.4-
SUP. A-11.5-
Revised
Revised
Revised
Revised
jamb detail "B". (a)
head detail "G". (a)
jamb detail "H". (a)
head/jamb detail "T".
(a)
Sheet A-13 (Drawin~ not reissued - see supplementary drawing below)
~- Revised dimension locating starting point of tile (centerline
of sales area) (d)
Sheet A-15 (Drawing not reissued - see notes and supp. drawing below)
1. Delete detail 6, 7, and 8. (a)
~- Revised Section #3. (a)
~- Revised Section #4. (a)
Sheet A-18 (Sheet not reissued - see note below)
1. Floor Plan at vestibule - vinyl comp tile in vestibule is white.
(d)
Sheet A-19 (Sheet not reissued - see supplementary drawings below)
SUP. A-19,1- Office Storage Plan - indicated monitor base and elevation
mark "13".
* The attached narratives are part of this Change Request *
Chg. Req. #1
Page 2 of4
FOOD LION STORE
SITE ~6A
COPPELL, TEXAS
Sheet M-1 (drawina not reissued - see suDDlementarv drawina below%
SUP. M-I.1 - 1. Added plenum note and access.door. (a)
Sheet M-3 Cdrawina not reissued - see supplementary drawi~a below}
SUP. M-3.1 - 1. Deleted return air plenum detail. (a)
Sheet M-§ (drawin~ not'reissued - see SuDDlementa~Ydraw$~qs below}
SUP. M-5.1 - 1. Added air conditioning schedule note. (a)
SUP. ~-5,2 - 1. Revised kitchen hoods. (a)
Sheet P-2 (drawin~ not reissued - see suDplemeDtar¥ drawinqs below)
SUP. P-2.1 - 1. Revised plumbing fixture schedule. (a)
SUP. P-2.2 - 1. Revised grade note to A.F.F. (a)
Sheet P-3W (drawin~ not Feissued - see supplementary
below)
SUP. P-3W.1- 1. Revised drain dimensions. (a)
SUP. P-3W.2- 1. Revised drain dimensions. (a)
drawipgs
Chg. Req # /
Pagesof~
FOOD LION STORE
SITE #6A
COPPELL, TEXAS
Sheet E-1 (drawinq not reissued - see supplementary drawinq below%
~ - 1. Added exit light and note. (a)
Sheet E-3WB (drawing not reissued - see supplementary drawin,j
below)
~- 1. Revised CRT. #33, 35, 37, 39 from "spare" to
"may also be used for parking lot lights if
needed for balancing purposes". (a)
Sheet E-7 fdrawin~ not reissued - see supplementary drawin~ below)
SUP. E-7.1 - 1. Added junction box. (a)
Chg. Req. # ~
Page ~ of ~
CHANGE REQUEST g2
MARCH 4, 1991
FOOD LION STORE
SITE #6A, PROJECT #90-115
COPPELL, TEXAS
ARTECH DESIGN GROUP, INC.
The following revisions are hereby issued. If accepted, these revisions
shall void, supersede and take precedence over previously issued
drawings, specifications and addenda of same name and number and shall
become a part of the contract.
Sheet A-2 (Drawings not reissued - see notes below)
1. Add General Note #12 as follows;
12. Provide "No Smoking" signs per City Ordinance No. 89-435.
Contradtor to provide and install signs in accordance with the
City Health Department. (b)
Sheet A-7 (Drowings no~ reissued - see supplementary drawings below)
SUP. A-7,1 Added grab bar behind handicap toilet. (b)
SUP. A-7,2 - Added grab bar behind handicap toilet. (b)
END
Chg. Req. #2
Page 1 of 1
CHANGE REQUEST #3
MARCH 6, 1991
FOOD LION STORE
SITE #6A, PROJECT #90-115
COPPELL, TEXAS
ARTECH
DESIGN GROUP, INC.
The following revisions are hereby issued. If accepted, these revisions
shall void, supersede and take precedence over previously issued
drawings, specifications and addenda of same name and number and shall
become a part of the contract.
Sheet A-2 (Drawings not reissued - see supplementary drawings below)
SUP, A-2,1 - Added door #34 with stair, canopy, exit light and junction
box for security alarm. (b)
Sheet A-3 (Drawings not reissued - see supplementary 'drawings below)
SUP, A-3. I'- - Added door, stair and canopy at left side elevation. (b)
Sheet A-10 (Drawings not reissued - see notes below)
1. Door Schedule - add door #34 as follows; (b)
Add door #34 with the following information.
Size 3'-0" x 7'-0" x 1-3/4"
Type 2
Frame Hollow metal
Finish Paint
Framing Head-"J" Jamb-"K" Sill-"L"
Remarks
Provide door sweeps and metal threshold.
Provide Von Duprin 22F Fire Exit Rim Device.
(The attached narratives are part of this Change Request)
Chg. Req. #3
Page 1 of 1
FOOD LION STORE
SITE #6A
COPPELL, TEXAS
Sheet FS-1 (drawinq not reissued - see supDlementar¥ drawinq below)
SUP. FS-I.1 - 1. Revised wire mesh note. (b)
Sheet M-1 fdrawinq not reissued - see supplementary drawinq below)
SUP M-i.1 - 1. Added condensate lines. (b)
Sheet P-2 (drawinq not reissued - see suDDlementary drawinqs below)
SUP. P-2.1 - 1. Added T&P discharge line. (b)
SUP. P-2.2 - 1. Added T&P discharge line. (b)
~ - 1. Revised note section 2/P-2. (b)
Sheet P-3W (drawinq not reissued - see supplementary
below)
SUP. P-3W.1 - 1. Revised note section 1/P-3W. (b)
SUP. P-3W.2 - 1. Revised note on plan. (b)
drawinq:~
Sheet P-4 ~drawinq not reissued - see supplementary drawinq below)
SUP. P-4.1 - 1. Added T&P discharge line. (b)
Sheet E-9 (drawinq Dot reissued - see supDlementar¥ drawinq below)
SUP. E-9.1 - 1. Added note requiring shut trip devices & a
single trip switch be provided. (b)
Chg. Req. # ~
Page ~ of ~
C ~lqGE PJ~QUE ST #~
DATE 5 -- 7 -- 9 1
Winkelmann & Assoc. ,Inc.
CIVIL CONSTRUCTION DOCX3PIENTS
FOOD LION STOI{I~; SITE #6a
S~A~JEL BOULEVZ%/~/) ~%/qD S~%l~DY
COPPELL, TEhS
ROSsi)
The following revisions to the Civil Construction Documents are hereby
issued. These revisions shall void, supersede, and take precedence over
previously issued drawings and written specifications of the same name
and number. These revisions shall hereby become a part of the contract.
DX~qINGS
Reference Sheet C-I (Sheet not reissued - see supplemental drawings)
- Supplemental Drawing C-l.1
1. Add acceleration lane to driveway on Sandy Lake Road.
- Supplemental Drawing C-1.2
1. Eliminate lime stabilization of subgrade from typical pavement
section.
- Supplemental Drawing C-1.3
1. Modify pick up deatil.
- Supplemental Drawing C-1.4 --
1. Add striping in dock area.
Reference Sheet C-2 (Sheet not reissued - see supplemental drawings)
- Supplemental Drawing C-2.1
1. Modify grades in truck dock area.
- Supplemental Drawing C-2.2
1. Add acceleration lane to driveway on Sandy Lake Road.
Reference Sheet C-3 (Sheet reissued)
1. Revise water layout and appurtenances as shown.
Chg. Req. #1
Page 1 of 2
Reference Sheet C-3A (Sheet not reissued - see supplemental drawin~s)
- Supplemental Drawing C-3A.1
1. Add concrete encasement for sanitary sewer main.
Reference Sheet C-4 (Sheet not reissued - see supplemental drawing.)
- Supplemental Drawing C-4.1
1. Revise slope of Line D.
Reference Sheet C-6 (Sheet not reissued - see supp]-m-~tal draw~-)
- Supplemental Drawing C-6.!
1. Include ~rease trap detail as noted.
Reference Sheet SE-i (Sheet not reissued)
Notes:
1. Electrical contractor to provide IlOV outlet and wiring for
pedestal mounted controller.
2. Note 5 under General Site Notes should read "The Electical
Contractor . . . . "
Specifications
~. Modify Specification Section 02200, Part II,
as follows:
2.03
(2.03) to read
SELECT FILL: Ail fill shall be placed in m-~imum 8"
loose lifts and compacted within a moistures range of
-3 to +3 percent of optimum moisture content to a
minimum of 95Z Standard Proctor Density. Select fill
hauled to the site shall have a plasticity index of
between 4 and 15.
END
Chg. Req. #l
Page 2 of 2