Denton Tap 1A-LR051202ECS - Texas~ LLP
4950 Keller Springs Road, Suite 480
Addison, TX 75001
(972) 392-3222
(FAX) 392-0102
December 2, 2005
Little Diversified Arch. Consulting
5001 Spring Valley Road, Suite 282-W
Providence Towers
Dallas, TX 75244
ATTN: Ms. Kathryn E. Rabuse
ECS Job # 19:4236-A
Permits:
Location: 131 N. Denton Tapp Road
Coppell, TX
We are enclosing: X Materials Engineering Division Reports
X For your use
X As requested
CC: Centex Construction Co. - Claud Bolton
Centex Construction Co. - Robert Boe
Wachovia Corporate Real Estate - Ken Clausen
Little Diversified Arch. Consultants - Philip F. Ritchie
City ofCoppell - Lee Stone
City ofCoppell - Larry Davis
Little Diversified Arch. Consulting - Jaime Nenclares
ENCL:
Field Report # 25
Daniel Franklin, P.E.
Presidem/Principal Engineer
4950 Keller Springs Road, Suite 480
Addison, TX 75001
(972) 392-3222
(FAX) 3924102
CONCRETE, GROUT, AND MORTAR TESTS
LETTER OF TRANSMITTAL
TO: Little Diversified Arch. Consulting
5001 Spring Valley Road, Suite 282-W
Providence Towers
Dallas, TX 75244
ATTN: Ms. Kathryn E. Rabuse
JOB NO.: 004236A
DATE: 12/02/2005
RE: Wachovia - Coppell
PERMIT #:
LOCATION:
131 N. Denton Tapp Road, Coppell, TX
Dallas County County
We are enclosing:
X Attached
X Materials Engineering Division Concrete Reports:
7, 8
X For Your Use
X As Requested
CC: Centex Construction Co. - Claud Bolton
Centex Construction Co. - Robert Boe
Wachovia Corporate Real Estate - Ken Clausen
Little Diversified Arch. Consultants - Philip F. Ritchie
City of Coppell - Lee Stone
City ofCoppell - Larry Davis
Little Diversified Arch. Consulting - Jaime Nenclares
By:
Daniel Franklin, P.E.
President/Principal Engineer
te.~ SET
ion Services Manager
(972) 392-3222
(FAX) 392-0102
Project: Wachovia - Coppell
Location: 131 N. Denton Tapp Road, Coppell, TX
Concrete Cylinders Strength Report
Project: 4236-A Set Designation: A
Cast Date: 11/04/2005
Design Strength: 3500 psi
Report No.: 7
Owner: Wachovia Corporate Real Estate - Ken Client: Little Diversified Arch. Consultants -
Arch.: Little Diversified Arch. Consulting - Jaime Gen. Contr.: Centex Construction Co. -
Struc. Eng.: Cone. Contr.:
Placement Location: Paving, south and east sides of building, sampled 40'S/25'E of NE building comer.
Concrete Supplier: Southern Star Truck No: 1020 Ticket No: 1013333
Mix Designation: 7752 Mix Strength:3600 psi Batch Time: 05:I9AM
Added Water: Time Added: Unit Wt.:
FIELD TEST DATA: Tested by:Marvin R. Hanks, III Time Sampled:06:05AM Slump:4.50 in.
Temperature - Air: 63° F ',oncrete: 73° F Air Content:4.40 % (p)
Sample Test Test Type Diameter Area Breaking Compr.. Brk Break Review
No Date Age Cure In. In.2 Load,lbs Str.,ps~ Typ by by
23781 11/11/2005 7 Lab 6.00 28.27 105216 3720 JBA1
23782 12/02/2005 28 Lab 6.00 28.27 133600 4730 JBA1
23783 12/02/2005 28 Lab 6.00 28.27 123680 4370 JBA1
23784 sp Lab 6.00 28.27
;ampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load alt~, a minimum discharge of approximately one cubic yard.
dinder molding and laboratory cudng iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM Cl 73 (V) or C231 (P),
temperature law ASTM C1064, and unit weight law ASTM C138. Cylinders are tented using unbcoded caps iaw ASTM C1231 or are capped using sulphur
mortar iaw C6t 7. Break Types are classified as: Type 1,2, 3, 4, 5, or 6 iaw C39-04a
FIELD CUR1NG CONDITIONS:
Curing Box Insulated Cooled Ice
X No Curing Box Heated X Caps Other
Remarks:
Final Review By:
JBAI
Print Date: 12/02/2005
4950 Keller Springs Road, Suite 480
Addison, TX 75001
(972) 392-3222
(FAX) 392-0102
Project: Wachovia - Coppell
Location: 131 N. Denton Tapp Road, Coppell, TX
Concrete Cylinders Strength Report
Project: 4236-A Set Designation: B
Cast Date: 11/04/2005
Design Strength: 3600 psi
Report No.: 8
Owner: Wachovia Corporate Real Estate - Ken
Arch.: Little Diversified Arch. Consulting - Jaime
Struc. Eng.:
Client: Little Diversified Arch. Consultants -
Gen. Contr.: Centex Construction Co. -
Conc. Contr.:
Placement Location: Paving, south and east sides of building, sampled 20'S/40'E of SW building comer.
Concrete Supplier: Southern Star Truck No: 008 Ticket No: 1013337
Mix Designation: 7752 Mix Strength: 3600 psi Batch Time: 06:00AM
Added Water: Time Added: Unit Wt.:
FIELD TEST DATA: Tested by:Marvin R. Hanks, III Time Sampled:06:50AM Slump:4.25 in.
Temperature - Air: 63° F Concrete: 75° F Air Content:4.60 % (p)
Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review
No Date Age Cure In. In.2 Load, lbs Str.,psi Typ by by
23785 1 I/11/2005 7 Lab 6.00 28.27 112832 3990 JBA 1
23786 12/02/2005 28 Lab 6.00 28.27 138240 4890 JBA1
23787 12/02/2005 28 Lab 6.00 28.27 138048 4880 4 JBAI
23788 sp Lab 6.00 28.27
Cylinder molding and laborato{y cudng law ASTM C31, compressive strength test and break type law ASTM C39, slump law C 143, air con~nt law ASTM C 173 (V) or C231 (P),
temperature iaw ASTM C1064, and unit weight law ASTM C138. Cylinders are tested using unbonded caps law ASTM C1231 or are capped using sulphur
mortar iaw C617. Break Types are dassigad as: Type 1,2, 3, 4, 5, or 6 law C39-04a
FIELD CURING CONDITIONS:
Curing Box Insulated Cooled Ice
X No Curing Box Heated X Caps Other
Remarks:
Final Review By: %~"~;~'~ ~
JBAI
Print Date: 12/02/2005
ECS - Texas, LLP
4950 Keller Springs Ro~d, Suite 480
Addison, TX 75001
(972) 392-3222
(FAX) 3924~102
CONCRETE, GROUT, AND MORTAR TESTS
LETTER OF TRANSMITTAL
TO: Little Diversified Arch. Consulting
5001 Spring Valley Road, Suite 282-W
Providence Towers
Dallas, TX 75244
ATTN: Ms. Kathryn E. Rabuse
JOB NO.: 004236A
DATE: 12/02/2005
RE: Wachovia - Coppell
PERMIT #:
LOCATION:
131 N. Denton Tapp Road, Coppell, TX
Dallas County County
We are enclosing:
X Attached
X Materials Engineering Division Concrete Reports:
8
X For Your Use
X As Requested
CC: Centex Construction Co. - Claud Bolton
Centex Construction Co. - Robert Boe
Wachovia Corporate Real Estate - Ken Clausen
Little Diversified Arch. Consultants - Philip F. Ritchie
City ofCoppell - Lee Stone
City ofCoppell - Larry Davis
Little Diversified Arch. Consulting - Jaime Nenclares
By:
Daniel Franklin, P.E.
President/Principal Engineer
Jason Allen, SET
Construction Services Manager
Project: Wachovia - Coppell
Location: 131 N. Denton Tapp Road, Coppell, TX
Concrete Cylinders Strength Report
Project: 4236-A Set Designation: B
Cast Date: 11/04/2005
Design Strength: 3600 psi
Report No.: 8
Owner: Wachovia Corporate Real Estate - Ken Client: Little Diversified Arch. Consultants -
Arch.: Little Diversified Arch. Consulting - Jaime Gen. Contr.: Centex Construction Co. -
Struc. Eng.: Conc. Contr.:
Placement Location: Paving, south and east sides of building, sampled 20'S/40'E of SW building comer.
Concrete Supplier: Southern Star Truck No: 008 Ticket No: 1013337
Mix Designation: 7752 Mix Strength: 3600 psi Batch Time: 06:00AM
Added Water: Time Added: Unit Wt.:
FIELD TEST DATA: Tested by:Marvin R. Hanks, II1 Time Sampled:06:50AM Slump:4.25 in.
Temperature - Air: 63° F Concrete: 75° F Air Content:4.60 % (p)
Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review
No Date Age Cure In. In.2 Load, lbs Str.,psi Typ by by
23785 11/11/2005 7 Lab 6.00 28.27 112832 3990 DLF
23786 12/02/2005 28 Lab 6.00 28.27 138240 4890 DLF
23787 12/02/2005 28 Lab 6.00 28.27 4
23788 sp Lab 6.00 28.27
Sampling in accordance with 0a~) ASTM C172, except that samples may have been taken from the beginning of the load aft{ ' a minimum discharge of approximately one cubic yard.
Cylinder molding and laboratory cudng law ASTM C31, compressive strength test and break type law ASTM C39, slump law C 143, air content iaw ASTM C173 (V) or C231 (P),
temperature law ASTM C1064, and unit weight law ASTM C138. Cylindem are tested using un~nded caps law ASTM C1231 or are cappe~ using sulphur
modar law C617. Break Types are dassiged as: Type 1,2, 3, 4, 5, or 6 law C39-04a
FIELD CURING CONDITIONS:
Curing Box Insulated Cooled Ice
X No Curing Box Heated X Caps Other
Remarks:
Final Review B3
JBAI
Print Date: 12/02/2005