Vista Ridge 1R-8 D-LR051205SAM ENGINEERING TESTING, INC.
Serving The Gao-industry Since 1974 ,~
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone: (972) 790-1910. FAX: (972) 790-0967
CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT
CLIENT:
PROJECT:
JBP, LP
5301 Village Creek Ddv~cdSuite A
Piano, TX~,/~"
The PI.~ Infrastructure
Hig, J~l~ay 121 & Ridgemont
Lefvisville & Coppell, TX
ATTN: Neal Heckel
SE&T TECHNICIAN: Jude Brignac
LOCATION OF PLACEMENT:
Time Arrived:
Eastbound Decel. Lane (~ I
II
10:55 AM
Time Left: 12:00 PM
Slump (Inches):
Concrete Temperature (F):
% Air Content:
i~hland & Plaza Blvd.
!
Concrete Supplier:
STANDARD 6" X t2"
AREA 28.27 SQ. IN.
REPORT DATE: 12/5/05
SAMPLE DATE: 12/2/05
PROJECT NO.: 308TXIK5
REPORT NO.: 37
PAGE 1 OF 1
Beall Concrete
Ticket #: 89050292
4.25 Truck #: 108
60 Time Batched: 11:09 AM
N/A 11:35AM
Time Sampled:
Product Code: 340L1504
Cement: N/A
FI), Ash: N/A
Total No. of Test Cylinders Made: 4
Total Cubic Yards Placed: 20
Added Water: N/A
Weather Conditions: Partly Cloudy & Cool Coarse A~l~re~late: N/A
Air Temperature (F): 52 Water: N/A
N/A % Air Content: N/A
12/9/05
12/16/05
12/30/05
12/30/05
Test Method
ASTM C-39 & 231
4000/28
4000/28
4000/28
4000/28
Cylinders Tested By:
lA 7
lB 14
1C 28
1D 28
Curing ASTM C-31
Slump ASTM C-143
Remarks:
Very Truly Yours,
Sadik (SAM) AI-Musawe, M.Sc., Ph.D., P.E.
Civil & Environmental Engineer
Texas Registration Number: 61893
This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent.
This report only applies to the samples tested and does not necessarily represent identical or similar samples.
G:/2005/308txik5/Cpistr/Cpistr37/LL