Coppell Trade-LR051207CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0158 Service Date: November 8, 2005 '] rEffal:ion 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: December 07, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:55am Supplier: TXI Truck No: 921 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Plant: 141 Ticket No: 151473 0Gallons 0 Gallons Sample Information Sample Time: 7:30am Date Cast: November 8, 2005 Technician: Eric G. Jernigan Weather Conditions: Partly cloudy and mild Accumulative Yards: 40 Placement Method: Direct Discharge Sample Locations: Dock#16 from south Placement Location: W side Fire Lane and Dock Parking, from middle of building to N end. Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 4.2 Concrete Temperature,° F: 88 Ambient Temperature, o F: 74 Plastic Unit Weight, pcf: Laboratory Test Data set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Specification 3-5 3-7 Test Method ASTM O143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 11/15/2005 7 104,280 3,690 11/15/2005 7 121,790 4,310 Average 4,000 12/06/2005 28 148,820 5,260 12/06/2005 28 149,560 5,290 Average 5,280 Comments: Not teated for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 3 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0158 Service Date: November 8, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 ']rerfacon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: December 07, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 8:25am Plant: 141 Supplier: TXI Truck No: 805 Ticket No: 151631 Mix I.D. No.: 8206 WaterAdded Onsite Before Test: 10Gallons Water Added Onsite After Test: 0Gallons Sample Information Sample Time: 9:00am Date Cast: November 8, 2005 Technician: Eric G. Jemigan Weather Conditions: Partly cloudy and mild Accumulative Yards: 140 Placement Method: Direct Discharge Sample Locations: Dock #22 Placement Location: W side Fire Lane and Dock Parking; From Dock #16-49 from south Field Test Data Test Result Slump, inches: 4.50 Air Content, %: 3.9 Concrete Temperature,o F: 85 Ambient Temperature, o F: 76 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 2 1 6.00 28.27 2 2 6.00 28.27 2 3 6.00 28.27 2 4 6.00 28.27 Specification Test Method 3-5 ASTM C143 3-7 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 11/15/2005 7 107,120 3,790 11/15/2005 7 105,420 3,730 Average 3,760 12/06/2005 28 142,360 5,030 12/06/2005 28 145,530 5,150 Average 5,090 Comments: Not tested for plastic unit weight, Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report Js exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and ara not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0158 Service Date: November 8, 2005 '] rerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: December 07, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 10:05am Supplier: TXI Truck No: 805 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Plant: 141 Ticket No: 151807 0Gallons 0 Gallons Sample Information sample Time: 10:45am Date Cast: November 8, 2005 Technician: Eric G. Jernigan Weather Conditions: Partly cloudy and mild Accumulative Yards: 240 Placement Method: Direct Discharge Sample Locations: Transformer Pad Placement Location: W side Dock Parking, Transformer Pad and Dumpster Pad Field Test Data Test Result Slump, inches: 5.25 Air Content, %: 4.0 Concrete Temperature? F: 84 Ambient Temperature, o F: 79 Plastic Unit Weight, pcf: Specification Test Method 3-5 ASTM C143 3-7 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Laboratorv Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 11/15/2005 7 101,970 3,610 3 2 6.00 28.27 11/15/2005 7 99,380 3,510 Average 3,560 3 3 6.00 28.27 12/06/2005 28 137,450 4,860 3 4 6.00 28.27 12/06/2005 28 136,550 4,830 Average 4,850 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Eric G. Jernigan Report Distribution: (1) Coppell Trade Center LP (1) Merriman Assoc Inc (1) TechniStructures (1) McFadden & Miller Reviewed by: (1) City of Coppell TX (1) Macatee Engineering (1) City of Coppell TX Senior Pr(~"Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shell not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.