Coppell Trade-LR051205CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94051190.0161
Service Date: November 22, 2005
']rerracon
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client:
Coppell Trade Center LP
Attn: Bennet Ratliff
5055 Keller Spdngs Rd Ste 300
Addison TX 75001
Report Date: December 05, 2005
Project: Coppell Trade Center - Bldg C
NWC Sandy Lake/Freeport Pkwy
Coppell, TX
Project No.: 94051190
Material Information
Specified Strength: 4000 psi @ 28 Days
Batch Time: 8:00am
Supplier: TXI
Truck No: 805
Mix I.D. No.: 8602
Plant: 141
Ticket No: 160333
Sample Information
sample Time: 9:11am Date Cast: November 22, 2005
Technician: Daniel J. Drogos
Weather Conditions: Cool and sunny
Accumulative Yards: 30
Placement Method: Direct Discharge
Sample Locations: Sidewalk, W side at F/24
Placement Location: Building C, W side Entrances at Column
Line F/13, F/19 and F/24
Field Test Data
Test Result
Slump, inches: 5.25
Air Content, %: 4.2
Concrete Temperature,° F: 65
Ambient Temperature, o F: 46
Plastic Unit Weight, pcf:
Laboratory Test Data Age at
Set Specimen Diameter Area Date Test
No. ID (inches) (sq. inches) Tested (days)
1 1 6.0028.27 11/29/2005 7
1 2 12/20/2005 28
1 3 12/20/2005 28
Specification
3-5
3-6
1 4 01/17/2006 56
Te~ M~hod
ASTM C143
ASTM C231
ASTM C1064
ASTM C1064
ASTM C138
Maximum Compressive
Load Strength
(lbs) (psi)
114,300 4,040
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Daniel J. Drogos
(1> Coppell Trade Center LP (1) Merrirnan Assoc Ir~c .
(1) TechniStruclures (1) McFadden & Miller Reviewed by: ,~'
(1) City of Coppell TX (1) Macatee Engineering Inc F~obert ~>. Ray, S~.~/'
(1) City of Coppelr TX
Senior Projec~il~ager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarih/indicative of the properties of other apparently similar or identical
materials.