Denton Tap 1A-LR051216ECS - Texas, LLP 4950 Keller Springs Road, Suite 480 Addison, IX 75001 (972) 392-3222 (FAX) 392-0102 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL TO: Little Diversified Arch. Consulting 5001 Spring Valley Road, Suite 282-W Providence Towers Dallas, TX 75244 ATTN: Ms. Kathryn E. Rabuse DATE~ RE: Wachovia- Coppell PERMIT #: JOB NO.: 004236A LOCATION: 131 N. Denton Tapp Road, Coppell, TX Dallas County County We are enclosing: X Attached X Materials Engineering Division Concrete Reports: 14 X For Your Use X As Requested CC: Centex Construction Co. - Claud Bolton Centex Construction Co. - Robert Boe Wachovia Corporate Real Estate - Ken Clausen Little Diversified Arch. Consultants - Philip F. Ritchie City ofCoppell - Lee Stone City ofCoppell - Larry Davis Little Diversified Arch. Consulting - Jaime Nenclares Laso~A'qle. n, S~ET' ~on Services Manager By: Daniel Franklin, P.E. President/Principal Engineer I 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 [ ? : : --] (FAX) 3924)I02 Project: Wachovia - Coppell Location: 131 N. Denton Tapp Road, Coppell, TX Concrete Cylinders Strength Report Project: 4236-A Set Designation: A Cast Date: 12/06/2005 Design Strength: 3500 psi Report No.: 14 Owner: Wachovia Corporate Real Estate - Ken Client: Little Diversified Arch. Consultants - Arch.: Little Diversified Arch. Consulting - Jaime Gen. Contr.: Centex Construction Co. - Struc. Eng.: Conc. Contr.: Placement Location: Westmost drive-thru island, west side of building. Concrete Supplier: Southern Star Truck No: 1092 Ticket No: 1310404 Mix Designation: 9339 Mix Strength:3500 psi Batch Time: 09:35AM Added Water: Time Added: Unit Wt.: F1ELD TEST DATA: Tested by: John G. Zimont Time Sampled:10:15AM Slump:3.50 in. Temperature - Air: 45° F Concrete: 60° F Air Content:3.00 % (V) Sample Test Test Type Diameter Area Breaking Compr.. Brk Break Review No Date Age Cure In. In.2 Load,lbs St~ra,) Typ by by 24220 12/16/2005 I0 Lab 6.00 28.27 92480~ JBAI 24221 01/03/2006 28 Lab 6.00 28.27 24222 01/03/2006 28 Lab 6.00 28.27 24223 sp Lab 6.00 28.27 Sampling in accordance with (taw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory cudng iaw ASTM C31, compressive strength test and break lype taw ASTM C39, slump taw C143, air content taw ASTM C173 (V) or C231 (P), temperature taw ASTM C1064, and unit weight law ASTM C138 Cylinders are tested using unbended caps taw ASTM C1231 or are capped using sulphur moor taw C617. Break Types are classified as: Type 1,2, 3, 4, 5, or 6 taw C39-04a FIELD CURING CONDITIONS: Curing Box Insulated Cooled Ice X No Curing Box Heated X Caps Other Remarks: Final Review By: JBA 1 Print Date: 12/16/2005