SC-Austin E3-LR 860709ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620-8911
DAILY FIELD REPORT
TESTED FOR
COPPELL INDEPENDENT SCHOOL DISTRICT
Coppell, Texas
DATE July 9, 1986
PROJECT
COPPELL ELEMENTARY SCHOOL
Coppell, Texas
OUR REPORT NO. 86195-8
WEATHER: CLEAR SKIES DATE: 07/09/86
TEMPERATURE RANGE: 92° TO: 95o
ALPHA Rep~e~enta.~e: ER IC METZENBACHER
THE ALPHA TECHNICIAN TRAVELED TO THE PROJECT AS REQUESTED BY THE CLIENT, FOR FIELD
COMPACTION TESTS. THE TECHNICIAN PERFORMED FIELD COMPACTION TESTS ON THE NATURAL SUBGRADE
IN THE EASTERN PORTION OF THE BUILDING PAD. THE MAJORITY OF TESTS PERFORMED DID NOT MEET
THE SPECIFICATION OF OPTIMUM MOISTURE TO 5% ABOVE OPTIMUM MOISTURE. THESE AREAS WILL BE
RETESTED AS SOON AS POSSIBLE.
TOTAL OF 5 SUBGRADE TESTS WERE PERFORMED:
2 TESTS WERE RETESTS, I TEST PASSED,
4 TESTS FAILED
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620-8911
REPORT OF FIELD
COMPACTION TESTS
TESTEDFOR: COPPELL INDEPENDENT SCHOOL DISTRICT
Coppell, Texas
DATE: July 9, 1986
PROJECT: COPPELL ELEMENTARY SCHOOL OUR RE~ORTNO. 86195-8A
Coppell, Texas
TEST DATA:
1 07/09/86 NSG 2 22.0 100.5 18 I06 105 2-BC
2 " NSG 2 22.0 103.5 18 106 105 2-BC
3 " NSG 22.0 100.5 21 100 100 2-CD
4 " NSG 2 22.0 i 100.5 24 97 97 2-AD
5 " NSG 2 22.0 100.5 16 101 100 2-C
TEST LOCATION:
I BLDG PAD SUBGRADE, 80 FT WEST & 20 FT NORTH OF SOUTHEAST CORNER OF EASTERN SECTION A
2 BLDG PAD SUBGRADE, 20 FT SOUTH & 5 FT WEST OF NORTH CORNER OF SOUTHEASTERN SECTION C
3 BLDG PAD SUBGRADE, RETEST OF TEST #1, 07/09/86
4 BLDG PAD SUBGRADE, RETEST OF TEST #2, 07/09/86
5 BLDG PAD SUBGRADE, 20 FT SOUTH & 50 FT WEST OF NORTH CORNER OF SOUTHEASTERN SECTION C
1. FILL
NATURAL SUBGRADE
3.
4,
· A. TEST RESULTS COMPLY WITH SPECIFICATIONS
B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D. RETEST