Loading...
SC-Austin E3-LR 860709ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620-8911 DAILY FIELD REPORT TESTED FOR COPPELL INDEPENDENT SCHOOL DISTRICT Coppell, Texas DATE July 9, 1986 PROJECT COPPELL ELEMENTARY SCHOOL Coppell, Texas OUR REPORT NO. 86195-8 WEATHER: CLEAR SKIES DATE: 07/09/86 TEMPERATURE RANGE: 92° TO: 95o ALPHA Rep~e~enta.~e: ER IC METZENBACHER THE ALPHA TECHNICIAN TRAVELED TO THE PROJECT AS REQUESTED BY THE CLIENT, FOR FIELD COMPACTION TESTS. THE TECHNICIAN PERFORMED FIELD COMPACTION TESTS ON THE NATURAL SUBGRADE IN THE EASTERN PORTION OF THE BUILDING PAD. THE MAJORITY OF TESTS PERFORMED DID NOT MEET THE SPECIFICATION OF OPTIMUM MOISTURE TO 5% ABOVE OPTIMUM MOISTURE. THESE AREAS WILL BE RETESTED AS SOON AS POSSIBLE. TOTAL OF 5 SUBGRADE TESTS WERE PERFORMED: 2 TESTS WERE RETESTS, I TEST PASSED, 4 TESTS FAILED ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620-8911 REPORT OF FIELD COMPACTION TESTS TESTEDFOR: COPPELL INDEPENDENT SCHOOL DISTRICT Coppell, Texas DATE: July 9, 1986 PROJECT: COPPELL ELEMENTARY SCHOOL OUR RE~ORTNO. 86195-8A Coppell, Texas TEST DATA: 1 07/09/86 NSG 2 22.0 100.5 18 I06 105 2-BC 2 " NSG 2 22.0 103.5 18 106 105 2-BC 3 " NSG 22.0 100.5 21 100 100 2-CD 4 " NSG 2 22.0 i 100.5 24 97 97 2-AD 5 " NSG 2 22.0 100.5 16 101 100 2-C TEST LOCATION: I BLDG PAD SUBGRADE, 80 FT WEST & 20 FT NORTH OF SOUTHEAST CORNER OF EASTERN SECTION A 2 BLDG PAD SUBGRADE, 20 FT SOUTH & 5 FT WEST OF NORTH CORNER OF SOUTHEASTERN SECTION C 3 BLDG PAD SUBGRADE, RETEST OF TEST #1, 07/09/86 4 BLDG PAD SUBGRADE, RETEST OF TEST #2, 07/09/86 5 BLDG PAD SUBGRADE, 20 FT SOUTH & 50 FT WEST OF NORTH CORNER OF SOUTHEASTERN SECTION C 1. FILL NATURAL SUBGRADE 3. 4, · A. TEST RESULTS COMPLY WITH SPECIFICATIONS B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST