Loading...
TR9101-CS 910612The City With A Beautiful Future P.O. Box 478 Coppell, Texas 75019 214 - 462 - 0022 June 12, 1991 Mr. Dan Meadors Sig-op Systems, Inc. 6600 Boucher Drive Edmond, OK 73034 Subject: Re: Traffic Signals at Denton Tap Road at Bethel Road Material Specifications and Contract Documents Dear Mr. Meadors: Enclosed please find five (5) sets of material specification documents, approved as noted. Mr. Don Glenn of Barton Aschman & Associates, Inc. has been furnished with a copy of this document, and he has recommended approval. We have no objections, as long as the following comments are addressed: Specifications covering the opticom detector is not included in this document. Please use specifications regarding opticom as noted in the final construction plans for this project, prepared by Barton Aschman & Associates, Inc. (See attached). As requested by Street Division, Public Works Department, it is recommended that multi-sonic 820-A system controller be used, instead of Econolite controller, if the price of multi-sonic controller is comparable in price with Econolite, or only reasonably higher. Please inform Mr. Rey Gonzales, Street Superintendent, or myself of your findings as soon as possible. Can Econolite controller be serviced locally? Please advise. We are also returning six (6) sets of the contract specification documents to you through Mr. Glenn to be completed, signed and returned for our final execution. Letter to Mr. Meadors June 12, 1991 Page 2 Your immediate attention is greatly appreciated and we look forward working with you on this project. Sincerely, M. Shohre Daneshmand~ P. E. Acting City Engineer CC: Gary L. Sieb, Director of Planning and Community Services Steve Goram, Director of Public Works Rey Gonzales, Street Superintendent Larry Davis, Construction Inspector Don Glenn, Barton-Aschman & Associates, Inc. MSD/bd MF_~%DORS tO m z -r m m -.4 I'=~0, Date: 2/13/91 Dealgned by: Drawn by: N.E.H. Checked by: O.e.e. APProved by: K.R.M. CITY OF COPPELL 6'x28' I 6'x28' I m Z O Z O TRAFFIC SIGNAL LAYOUT SHEET ONE GROUND WIRE 8HALL BE RUN WITH EACH CIRCUIT 18TING R.O.W. GTE T-1 INSTALL OPTICOM DETECTOR I 2-2 ~ ~2-1 ~6__4' FROM )P LINE ~ 8TOP LINE INSTALL SIGN 6'x40' ;xISTINQ R.O.W. INSTALL METER ON EXI8TING POWER POLE T-4 ~INSTALL 24' WHITE 8TOP LINE WHITE W6 10 FUTURE MAST ARM (32') LOCATION GTE - ,,~ GTE I K~'"' INSTALL SIGN SR 10-9 ~,.~..._.._. INSTALL OPTIGOM DETECTOR I I I wa ~ ----~)T-~ -- [ I --~ 4 / / ~ - INSTALL PAVEMENT ARROWS I ,