Loading...
Valley R Plaza 2-CS 970904TO: FROM: RE: COPPELL UT~L~T~E~ D~V~ON 8epte~ber 4, 1997 Larry Davis, Construction Inspector Marc Russell, Utilities Division Walk-Thru Valley Ranch, 817 MacArthur Listed below are Street Division comments relative to 1. Sta. 0+00 line "1" walk thru. MH o~ approach 9 Beltline chimney seal weeds extension: leak- ing at drop; needs cleaned out at inverts. MLV on Beltline needs Dad leveled and tack straiahtened and d~rt cleaned out. D~llas water valve needs Droner setuD. FH in island needs raised for 18" clearance. 5+21.41 line "1" UTI needs raised and inspected. 7+11.67 line "1" needs raised to arade of landscape and floor needs cleaned and invert reworked. FHon south side of buildinq has low flow; valve needs cutout Both meters need cleaned out to see bottom turn off and are set too hiqh. Valves on MacArthur need located. 6. Inlet box at Wendy's end RCP comin~ into box very bad. MESSAGE CONF I RMAT I ON 09×04/9? 1~:~4 ID--CITY OF COPPELL DATE 09×04 S~R-TIME DISTANT STATION ID MODE PAGES 00~22'' CITY OF COPPELL CALLING 01 RESULT OK 0000