Town Center L2B1-CS 951221COPPELL ENGINF~ERING UTHATIES DIVISION MEMORANDUM DATE: TO: FROM: RE: December 21, 1995 Larry Davis, Construction Inspector Larry Smith, Utilities Follow-up Walk thru A follow-up walk-thru on and all items have been corrected. If you have any questions, please advise. conducted on 12/21/95 HLP/dg COIq's~.T. ~qGINEER!NG UTW.ITI~ DIVISION MEMORANDUM DATE~ Pecc~be~ 15, 199~ FROM~ Larry Davis, Construct/on Inspector Mike Hod~e, Buildin~ In~xctor Lan'y SmUh, Utilities C,z~w~er ~' Walk thru for Wendy's on Denton Tau Road A walk-thru on the above referenced project was conducted on and the items below were found to be deficient. 12/15/05 2. 3. 4. 5. 7. 8. 9. I0. l~._'~__ to ??at fire h_Vdmnt ill front of b, ildine yellow. ~d to out blue button in street on all 3 fire hydrnnt~_ MaTk valves on curb ...... Need to block out fire hydrant valves in handica_~ ramu. ]Vlaln line valve next to fire h_vd. in front of b. iidin?, needs to be slrai_ehtened u_o SO I can get on valve & raise stack m street level. Clean out meter box to existing mp. tp.r is covered UP//9012489 & mark curb. Domestic meters double r.b~lr is l~lfina & sot box to _cn'ound level. Need to install meter box over sprinkler Fire hydrant across from subway on Denton Tap n,,A4, b,tmfl in street and mark Fire hydrant in back of Wendy's ~,-p~ts to pull cad off so I can in _sgect valves ('~nlnltn~ valve & firs hydrant valve.') Please ensure that these items get taken care of and if you have any questions, please give me a call. HLP/dg COPPELL ENGINEF_,RING UTIL1TIF~ DIVISION MEMORANDUM DATE: December 15, 1995 TO: Larry Davis, Construction Inspector Mike Hedge, Building Inspector FROM: Larry Smith, Utilities Crewleader ~'~' RE: Walk thru for Wendy's on Denton Tan Road A walk-thru on the above referenced project was conducted on 12/15/95 and the items below were found to be deficient. 2. 3. 4. 5. 7. 8. 9. 10. Need to _mint fire hydrant in front of building yellow. Need to put blue button in street on all 3 fire hydrants. Mark valves on curb. Need to block out fire hydrant valves in handicap ramp. Main line valve next to fire hyd. in front of building, needs to be straightened up so I can get on valve & raise stack to street level. Clean out meter box to existing meter is covered up g9012489 & mark curb. Dpm;stic meters double check is leakin~ & set box to ground level. Need to install meter box over sprinkler meter. Fire hydrant across from subway on Denton Tap needs button in street and mark curb. Fifo hydrant in back of Wendy's needs to pull cap off so I can in _spect valves (mainline valve & fire hydrant valve3 Please ensure that these items get taken care of and if you have any questions, please give me a call. I-ILP/dg