Loading...
Valley R Center-CS 920109The City With A Beautiful Future P.O. Box 478 Coppell, Texas 75019 214-462-0022 January 9, 1992 Mr. Robert D. Sisco Landscape Coordinator Capital Consultants Management Corporation 7557 Rambler Road, Suite 850 Dallas, Texas 75231 RE: Irrigation System Located in Medians/800 Block of South MacArthur, Coppell, Texas Dear Mr. Sisco: As you are aware on Wednesday, January 8, 1991, a contractor performing work for your firm damaged an irrigation line in the above referenced median area. The damage created a leak and the Coppell Water Utilities Division was contacted to shut down the system. Coppell Utilities staff was unable to locate any isolation valves in the immediate area. Upon your arrival at the site you informed my staff member that the system could possibly be isolated by shutting down the system in the city of Irving, just north of Cowboy Drive. It was found that by shutting the irrigation system down in Irving, the medians in the 800 Block of MacArthur were also shut down. By this action it has been determined that the medians located in the 800 Block of MacArthur are being supplied water from the City of Irving water system. Therefore, I am obligated to require your firm to disconnect the medians in the 800 Block of MacArthur from the city of Irving's water system and connect them to the City of Coppell's water system. I have attached copies of drawings that identify water lines that can be/~. p ~ for supply to the system. I have also pro¥ided water/?~ ~tails for your information. Plisse cont~ me~ !/8495 to discuss this matter. s' :erely, ~~at~e e~ntendent cc: Steven G. G~'~m, Director of Public Works CITY OF COPPELL Water Service Fittings For 3/4 through 2" meter settings Water Meter Boxes Service Size 3/4" & 1" 1½" & 2" Meter Box Size 18" x 14" galvinized with Cast Iron Ring & Lid (with lock) 28 x 18" galvinized with Cast Iron Ring & Lid (with lo~k) Tapping Saddles All service taps shall be installed with Double Strap, All Bronze "CC" Threaded tapping saddle~- ~%Q- ~o~eF ~e_ ~ c[,~e~ {c,[ . Corporation Stops All cozl~oration stops shall be bronze "CC" thread by copper flare Copper Service Line All service lines shall be type "K" soft copper with flare connections only C~b Stop (prior to meter setter) All curb stops to be all bronze ball valve- copper flsre by male of femal iron pipe thread (1½: & 2" curb stops can be angle stops) Meter Setters Service Size Meter Setter Size 3/4" Ford Model ~H 72-10W or equal 1" Ford Mede]. VHH 74-15W or equal 1½" Ford Mede]. VVF 66-12B x length or equal 2" Ford Model WF 77-12B x length or equal All setters shall ~ all copper and bronze with silver solder welds and all valves to be equiped with lock wings Meters All meters shall be purclmnsed fr~n the City of Coppell and shall meet City of Coppell Specifications Pipe Fittings All pipe fittings within the meter or double check setting shall be bronze and copper material Double Chec]cs All double check backsiphonage devices shall meet the approval of the Under- writers Laboratories. The device shall have test cocks for testing and shall be installed at and no higher CITY OF COPPELL WATER METER~ /~ 28" DIA:,~. x CURS , · L'--:~-" ~ NLL BRONZE ARONZE BALL V4LVE ~ ~ FtT~INGS OR ANGLE STOP ., .  H~VE LOC~, ~ " FOR I-I/2 II rand 2" SERVICES FOR IRRIGATION SERVICE OR DOMESTIC WA~R SERVICE ~NNECTION WITH METER BOX (LOCATE ~T CENTER CF LOT) GALVANIZED METER BOXES BASS E~ HAYS No. 55A or ~rr D. EQUAL ~-- GATE V4LVE ~--U.L. APFROVEO DOUBLE CH EC~. EACKSIFHON AGE '-~< o..; DEVICE' I2" CRUSHEO ~¢'~', '.., STO[~ E / o~::-.-;..'..~i COFP.ER METER SETTER· ]L~o-~%*;..~] i-i/2 - FORD VVF 66-12B 2" - FORD VVF 77-12a OR APPROVED EQUAL NOTE: SOLDERED COPPER NOT ALLOWED THREADED BRONZE ONLY. 449.0 FI=. 4~8.5 /I E£449.0 =! 1 - G£G 21MT -