Loading...
Valley R Center-CS 890908Central Regional Wsstewster System September 8, 1989 Mr. Russel/R. Doyle, P.E. City Eng~eer City of ~oppell P.O. Bo~ 478 Coppell, Texas 75019 SEP I 8 1989 ,:, Subject: Central Regional System Coppell Valley Ranch Dear Mr. Doyle: In response to the point of entry request dated September 5, 1989, the Authority has reviewed the construction standards to be utilized on the point of entry. The Authority approves your request based upon the information submitted which includes the construction plans dated February 1987 for the Valley Ranch Center designed by Albert H. Halff Associates, Inc. for the City of Coppell, but is subject to the following requirements. The Central Regional Wastewater System Engineering Division must be contacted (214 263-2251 or 214 262-5186) at least 72 hours prior to construction. If the Authority is not notified the Authority reserves the right to request the contractor to excavate his work for inspection. All inspections wi~ be performed only by Authority inspectors. City inspectors are not responsible for Trinity River Authority property. Ail points of entry must be constructed within one year after their acceptance by the Authority. Any alterations to the plans concerning the Authority's interceptor, point of entry or easements must also be approved b¥ the Authority. A preconstruction meeting with the contractor and the Authority is required prior to construction. P.O. Box 531196 Grand Prairie, Texas 75053 (214) Metro 263-2251 September 8, 1989 Russell Doyle Page 2 Ail P.V.C. connections shall use an A.C. pipe adaptor. The connection shall be concrete encased 3 feet from the manhole. Connections to existing manholes shall be core drilled. Jack hammering shall not be allowed. Any damage to the manhole during core drilling operations shall be repaired immediately by the contractor. There is an existing connection to the CoppellInterceptor at Station 163+95 from the Mobil station at 1301 East Beltline Road. This connection shall be removed and the manhole riser plugged prior to construction of the Valley Ranch Center point of entry. Sanitary sewer service for the development cannot commence until the Authority accepts and approves the point of entry In addition to the above, personnel from the Engineering Division must be onsite during construction, as well as prior to any backfilling of the Authority's facility in this area. This point of entry shall serve the City of Coppell and will be metered at Meter Station 17.OE. If you have any questions or comments please contact me. Patricia Cleveland Manager, Technical Services cc: Steve Lemke, Dunaway Associates, Inc.