Loading...
Villages C PW-CS 900402 (2)April 2, ON A TIPTON, INC. Iq Ms Taryon Bowman, Dir. CITY OF COPPELL 255 Parkway Blvd. Coppell, Texas 75019 ,,~GINEEI'.ING SURVEYING PLANNING 33 t Line~e~-) Suite C GARLAND, TEXAS 75043 (214) 226-2967 · of Planning VILLAG'E$~O~ COPPELL, PleASE III Coppell, Texas Dear Ms. Bowman: Please find listed belgw the response to the DRC meeting of Thursday March 29, 1990 and the review letter from Ginn Inc. of Friday Mar~h 30, 1990: .. PRELIMINARY PLAT: 1. We have corrected and added all.the names and zoning of adjacent properties· 2. We have added the location, widths, and names of all existing and proposed streets and easements. 3. We hage added the floodplain development permit note· 4. We have added all the preliminary easements required by T.U. Electric, General Telephone, and the City of the Coppell. We have added to to the sub-division the plat all the proposed variances regulations. we will request a variance to the minimum street center line curve radius of 425 feet in order to allow for flexibility of.. placement of the roadway parallel to the existing floodplain and tree masses. We have included all the corner visibility clips on the plat. Apr±'l 2~ 3_990 Page 2 II. PRELIMINARY WATER & SEWER: 1. We have shown the existing water line in Deforest Drive. 2. We will adhere to the minimum' the sub-division regulations sewe r. design requirements of in regard to the sanitary III. DRAINAGE: The offsite drainage to the north flows towards our property in a south easterly manner and is currently designated to lie within the 100 year floodplain as determined by the current City of Coppell drainage study of Denton Creek Drainage Basin. The drainage area discharges at our north eastern property corner. We will provide the appropriate drainage easement to accommodate for that particular discharge. At the time of final platting a detailed hydraulic study will be provided to determine the exact .location of the. proposed drainage easements. It is our understanding the flo.odplain study of Denton Creek Basin is being finalized with the City of Coppell and its consultant, Kimley-Horn and the said study will be approved by city council in the near future. 3. We have utilized TP-40, 10 minute TC for runoff calculations. ,, This concludes our response to the review comments, please find enclosed four (4) revised sets of preliminary engineering and six (6) prints of the preliminary plat. If you have any questions regarding this project, please call. Sincerely, Executive Vice President PA/df encls. cc: Ms. Shohre Daneshmond, P.E./City of Coppell 17103 Preston Road Suite IOO, L[3-1]8 ~)ALLAS,-IiXAS 75248 (214) 248-4900 ARE SENDING YOU /)~ Attached [] Under separate cover via t [] Shop drawihgs . [] Prints [] Plans [] Samples [] Copy of tet/er [-'1 Change order' / ,-~'~--~'" ~_~._~'~,) 'HESE ARE TRANSMI'I-I'ED as checked below: [] For approval ~For your use [] As requested [3 For review and comment [] FOR BIDS DUE [] Approved as submitted [] Approved as noted [] Returned for corrections 19 [] Resubmit [] Submit [] Re~urn copies for approval copies fur distribution corrected prints [] PRINTS RETURNED AFTER LOAN TO US DRC DATE: REVIEW OF: CI'fY OF COPPEf,L EN()]: N'EI~RING DIVI,~j ION BY: Shohre Oanenhmand, Ph'one {i~ 462-8495 Please make the fei. lowing additions and/or correc~io/m ho the pl?e].J.minary plat, as marked: The names and zoning of adjacent properties, names on record of owners of adjoining parcels. The locatJ, on, widths and names of all existing and proposed streets% easements, fire lanes or other public ways within or adjacent to the ~ract. ~ Existing a~d proposed zoning of the site and the surrounding properties. s) Topography of the site (intez~als of 5 feet or less, referred to sea level datum). Per Floodplain t.[anageil%ent Ordinance 1187390, (Art. 5, Sec. C, Item 4, Page 34), all subdivision proposals must have the following note placed on the preliminary and final plats. "Floodplain Development Permit Application~ No. has been filed with the City of Coppell Floodplain A~ninistrator on 19 l) 2) (Floodplain Admfnistrator (Date) - No Comment. The following information, as marked, is required contained in the preliminary engineering plans. - Submit prelim.i.nary engineering plans. - Tho plans shall show existing structures, sewers, water mains, culverts, power poles, Page 1/2 to be utilities telephone t:he tract and immediately adJacan~ 'thereto with pJ. pr~ mLzea and ].ocatlon~. Prov.i.d~ dimeni~ion controls for all util.i, tie~l and right-of-ways. 3) On appropriate plans, provide a legend identifying the utilities, such as water, sewer~ gas line, stoz~a sewer · . . etc Preliminary plans of proposed water distributio~ system sewage collection system . and their relation to the existing utilities in the area, and to the Utility Hastc'r Plan. Provide a Drainage Area Hap, covering two parts: a) show'On-site Drainage Hap, on a scale of 1"=20', 40', 50', e~c. . .; with all details as required in tile Subdivision Ordinance. 7) b) show tile Off-site Drainage Map, on. a 9cale of 1"=100', 200', etc'. Delineate the project's bounda~t on. it, plus the less detailed drainage sygtem, to clearly demonstrate the a.ffect of such activities; drainage outfall.s, on the adjacent properties and the Drainage Master P~an. If the applicant is requesting' any variance to the Subdivision Ordinance, be/she must submit a letter specifically outlining ]lis respective requests. This letter shall be submitted along with corrected plan. Show the boundaries of the 100-year Floodplain and Floodway clearly on the preliminary and final plats. All above comments must be addressed, prior to staff's recommendation for approval of the prel~ninary plat and plans. 9) Provide ~ .written response on all conunents, with explanations provided on items not addressed as req6ested DRC/COI~.LENTS / EI~G/PRELIM Page 2/2 CITY OF COPPELL PUBLIC WATEi{ U'I~ILi'2IES DIVISION I'I/I!:LIMINAI(Y I'LA~] REQUIREMENTS Dy: Howard Pafford, Water Foreman, Phone 462-8495 Wnter./.SanJ.t:nry Se. wc~r PI. an l'!.easc make the following additions as markc/: ~ ,/,. · . 1) ~ Snow exJ_s~ing water lines and/or corrections, in adjacent areas. 2) Show ~proposed water lines. (Minimum water line size 8" ) 3)- · Show prgposed valve and hydrant placement ,- (.valves - 500 ft. separation/hydrants residential areas - 500 ft. separation and Commercial/Industrial 300 ft. separation). Note on plans - Estimated daily sanitary sewer flow - Estimated daily'water demand Show existing sanitaz~y sewer lines. Show pz~op0sed sanitary sewer lines. (minimum line size 8" ) (Lines are required to be Straight with no curves). 7) Show proposed manhole and clean out placement (manholes maximum 500 ft. separation and clean outs at a maximum of 250 ft. from manholes). All necessaz~ easements should have a 20 ft. width unless centered on the property lines of two lots, thcn 25 ft.' will be allowed. Page 1/2 ^PAGE. ~OF 2 9) 3 Ail above conm]ents must be addressed, staff ' s recommendation for approval preliminary plat and plans. prior to of the 10) = Provide a written response on all comments, with explanations provided on items not addressed as requested above. 11) - l~O com~ient, DI{C/CONiKENTS/WAT/PRELIM SD/HP/pd Page 2/2