ist Review of: Valley Ranch Center (SEC) - Preliminary Plat
A. ENGINEERING:
Contact Shohre Daneshmand @ 462-0022
1) Delineate vacininty map on Preliminary Plat and Site
Plan.
2) Delineate the name of the project on the Preliminary
Plat.
3) Driveway spacings varies from Subdivision Ordinance,
refer to Markup Plans.
4) Show existing and propsed utilities on Site Plan.
5) What are the height of all structures.
6) Delineate proposed or existing left turn lane.
7) Show the Firelane on the site.
8) Can the 12" SS handle the flow from this developed site?
Please provide the Flowrate Study.
Deferentiate existing from proposed utilities.
Provide Irrigation Plan.
There are two layouts shown on grading plan and drainage
area map for storm sewer, which one is correct?
The slope in front of Tom Thumb is too steep (Max. 2%).
Need to take care of drainage on-site instead of draining
it to Beltline Road in the northwest corner of the
property as much as possible.
The existing channel can not be left as an open channel,
it needs to be in a closed system.
Delineate the Flood Plain boundary.
Provide overall Drainage Area Map (on and off site).
Add I5 and Il00 to drainage calculation.
Double check Il00 you are using according to TP 40 Il00 =
11.6 not 7.8.
Show the roof drainage.
Why "Y" inlets are to be converted to Grate Inlet, please
explain.
9)
10)
11)
13)
14)
15)
16)
17)
18)
19)
2O)
Bo
BUILDING INSPECTION: I) Has S.U.P. been granted for grocery store.
2) Need 3 12' X 30' spaces dedicated for off-street loading
and unloading for Tom Thumb space.
3) Final landscape must contain stamp and signature from
licensed landscape architect.
DRC 012887
Page 7
4) See Section 30.3 1. of Zoning Ordinance for total
off-street loading and unloading requirements.
** NOTE: Restaurants require additional parking spaces.
Required parking will be re-calculated when these type of
S.U.P.'s are requested.
LONE STAR GAS:
I) No representative was present,
253-5102, extension 3I.
contact Fred Harris at
GENERAL TELEPHONE: 1) Preliminary Plat is acceptable.
2) Need to have same name of development on all plats (Site
Plan, Preliminary Plat and landscape Plan).
3) Need 15' utility easement dedicated on back lot lines.
COPPELL CABLEVISION:
Outside service area. This is about 1½ miles from
existing cable area, not planned for construction till
'88.
Fo
TEXAS POWER AND LIGHT:
1) Currently in the process
easement requirements.
of determining service and
PARKS AND RECREATION:
Unable to obtain comments from Public Works Department.
Please contact Steve Goram, Director of Public Works at
462-0022.
PLANNING AND DEVELOPMENT:
1) A Special Use Permit must be obtained in order to operate
a grocery store in Coppell.
2) Review of the preliminary plat will continue after a
Special Use Permit has been obtained.
3) The tentative date scheduled for the DRC is February 4,
1987 at 9:15 a.m.