Windance Sub-LR 830513Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE MIX DESIGN CLIENT: MFC Readi-Mix, Inc. RROOECT: City of Dallas Concrete for Pavement DATE: 13 May 1983 REQUIRED: MATERIALS: Min. 3000 psi at 28 days. Min. 4.0 sacks cement per cubic yard concrete with flyash. Max. C.A. l". Max. slump ~". Admixture ASTH C260. 3000 P.S.I. CEMENT: Normal Portland, Type I, ASTH C150 with Flyash FINE AGGREGATE: 0 - #4 MFC Sand INTErmEDIATE AGGREGATE: COARSE AGGREGATE: 1" - #4 MFC Crushed Stone ADMIXTURE: ASTM C260 CEMENT FLY ASH F.A. I.A. C.A. WATER N. V. R.-A.E.A. for i C.Y. MOISTURE C.Y. BY WEIGHT % BATCH WEIGHTS 376# 118# 1337# 1850# 250# 4% Air 3931# lC. Y. ABSOLUTE VOLUME 1.913 c.f. 0.708 c.f. 8.147 c.f. 11.146 c.f. 4.006 c.f. 1.080 c.f. 27.000 c.f. FRESH UNIT WEIGHT: DISTRIBUTION: 145.6#/c.f. wet concrete (2) Supplier - MFC Readi-Mix, Inc. (2) City - City of Dallas (1) Consultant - James D. Irwin, P.E. 2870 Walnut Hill Lane Dallas , Texas 75229 (214) 351~6419