Coppell Trade-LR060104REPORT OF REINFORCING STEEL OBSERVATION 'irerracan 8901 Carpenter Frw'/, Suite #100 Dallas, Texas 75247 (214) 630-1010 01/04~05 / Date of Service: /' Client No.: 93345 Coppell TrX'de Center LP Client: 5055 K,~Spring_~ Rd Ste 300 Addij~'n, TX 75001 Report No.: Project No.: Project: 94051190.0172 94051190 Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Services: Observe placement of reinforcing for compliance with furnished drawings. PROJECT DATA Drawings Utilized: Civil 02, 03 Pavement Details Locations/Items Observed: Pavement, SE Parking Lot adjacent to grid line 1.5-2.0/up to 120' S of grid line A Test Method: Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT Discrepancies/Comments: iNCORRECT Any discrepancies f noted. Field Results Report To: Technician: D. Drogos Report Distribution: (1) Coppell Trade Center LP (1) TechniStructures (1) City of Coppel[ TX (1) City of Coppell TX Bar Length and Shape Proper ear Placement e CORRECT INCORRECT at the time of this observation unless otherwise 309pdr (1) McFadden & Miller {1) Macatee Engineering Inc This repot[ is exclusively for the use of the client indicated above and shall not be reproduced wit hogt wrd~en approval of Terracon. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0164 Service Date: December 6, 2005 'lrEffacon 8901 Carpenter Frwy, Ste #100 Dallas1 Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: January 04, 2006 Project: Coppell Trade Center - BIdg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:28am Plant: 141 Supplier: TXt Truck No: 39 Ticket No: 167187 Mix I.D. No.: 8206 WaterAdded Onsite Before Test: 10Gallons Water Added Onsite After Test: 0Gallons Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 6.5 Concrete Temperature,O F: 50 Ambient Temperature, o F: 27 Plastic Unit Weight, pcf: 143.9 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Sample Information Sample Time: 7:30am Technician: Kudret Aksu Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Sample area on attached sketch Placement Location: Pavement, see attached sketch Date Cast: December 6, 2005 Specification Test Method 3-5 ASTM C143 3-6 ASTM C231 ASTM C1064 ASTM C1064 ASTM Cl 38 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/13/2005 7 96,290 3,410 12/13/2005 7 100,010 3,540 Average 3,480 01/03/2006 28 120,560 4,260 01/03/2006 28 128,570 4,550 Average 4,410 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Kudret Aksu Report Distribution: (1) Coppell Trade Center LP (1) TechniStructures (1) Ci~/of Coppell TX (1) City of Coppell TX (1) Merriman Assoc Inc (1) McFadden & Miller (1) Macatee Engineering Inc Reviewed by: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.