Coppell Trade-LR051221CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0161 Service Date: November 22, 2005 'lrerracon 8901 Carpenter Finny, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: ~ Coppell Trade~7~ter LP Attn: Benne~atliff 5055 Kelle?'Spdngs Rd Ste 300 Addison TX 75001 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 8:00am Supplier: TXI Truck No: 805 Mix I.D. No.: 8602 Field Test Data Test Plant: 141 ~ Ticket No: 160333 Slump, inches: Air Content, %: Concrete Temperature,O F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 Report Date: December 21,2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Sample Information Sample Time: 9:1 lam Date Cast: November 22, 2005 Technician: Daniel J. Dregos Weather Conditions:Cool and sunny Accumulative Yards: 30 Placement Method: Direct Discharge Sample Locations: Sidewalk, W side at F/24 Placement Location: Building C, W side Entrances at Column Line F/13, F/19 and F/24 Result / IS_oecificaLion 65 46 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM Cl 064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 11/29/2005 7 114,300 4,040 1 2 6.00 28.27 12/20/2005 28 156,480 5,530 1 3 6.00 28.27 12/20/2005 28 150,420 5,320 Average 5,430 1 4 01/17/2006 56 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Daniel J. Dregos (1) TechniStruclures (1) McFadden&Mgler Revlewea Dy. ~',/~---~ ~ v ~"~ .~' ,/ ../' (1) City of Coppell TX (1) Macatee Engineering Inc ~ Robert D. Ray, S.E.T~J (1) C~ty of Coppell TX Senior Project Mayn't~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use o/the client' indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.