Loading...
Coppell Trade-LR051216CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0164 Service Date: December 6, 2005 'lrr rfacon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bonnet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: December 16, 2005 Project: Coppell Trade Center- Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:28am Plant: 141 Supplier: TXI Truck No: 39 Ticket No: 167187 Mix I.D. No.: 8206 Water Added Onsite Before Test: 10Gallons Water Added Onsite After Test: 0Gallons Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 6.5 Concrete Temperature,e F: 50 Ambient Temperature, e F: 27 Plastic Unit Weight, pcf: 143.9 Laboratorlz Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 26.27 1 3 1 4 Sample Information sample Time: 7:30am Technician: Kudret Aksu Weather Conditions:Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Sample area on attached sketch Placement Location: Pavement, see attached sketch Date Cast: December 6, 2005 Specification 3-5 3-6 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/13/2005 7 96,290 3,410 12/13/2005 7 100,010 3,540 Average 3,480 01/03/2006 28 01/03/2006 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Kudret Aksu Report Distribution: / (1) Co~e,l Tr. de Center L. (1) Merriman Assoc I.c /~ ~ ~ (1) Ci~ of Coppe~l TX Senior Project The tests were pedormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repo~ is exclusively for the us~of the client indicated above and shall not be repr~uced except in full without the ~iffen consent of our company. Test results transmiffed herein are only applicable to the actual samples tested at the location(s) referenced and are not n~essarily indicative of the prope~ies of other apparently similar or identical materials,